Photon-noise: is a single-pixel camera better than point scanning? A signal-to-noise ratio analysis for Hadamard and Cosine positive modulation

被引:1
|
作者
Scotte, Camille [1 ]
Galland, Frederic [1 ]
Rigneault, Herve [1 ]
机构
[1] Aix Marseille Univ, Inst Fresnel, CNRS, Cent Marseille, Marseille, France
来源
JOURNAL OF PHYSICS-PHOTONICS | 2023年 / 5卷 / 03期
基金
欧盟地平线“2020”;
关键词
computational imaging; single-pixel camera; single-pixel detection; multiplexing disadvantage; shot-noise; photon-noise; MULTIPLEX DISADVANTAGE; ADVANTAGE; REALIZATION; MICROSCOPY;
D O I
10.1088/2515-7647/acc70b
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In a single-pixel camera, an unknown object is sequentially illuminated by intensity patterns. The total reflected or transmitted intensity is summed in a single-pixel detector from which the object is computationally reconstructed. In the situation where the measurements are limited by photon-noise, it is questionable whether a single-pixel camera performs better or worse than simply scanning the object with a focused intensity spot-a modality known as point raster scanning and employed in many laser scanning systems. Here, we solve this general question and report that positive intensity modulation based on Hadamard or Cosine patterns does not necessarily improve the single-to-noise ratio (SNR) of single-pixel cameras, as compared to point raster scanning (RS). Instead, we show that the SNR is only improved on object pixels at least k times brighter than the object mean signal (x) over bar, where k is a constant that depends on the modulation scheme (modulation matrix, number of detectors, etc). The constant k is derived for several widespread cases and has important consequences on the choice of the optical deign. This fundamental property is demonstrated theoretically, numerically, and is experimentally confirmed in the spatial domain (widefield fluorescence imaging) and in the spectral domain (spontaneous Raman spectral measurements). Finally, we provide user-oriented guidelines that help decide when and how multiplexing under photon-noise should be used instead of point RS.
引用
收藏
页数:26
相关论文
共 5 条
  • [1] Improving the Signal-to-Noise Ratio of Superresolution Imaging Based on Single-Pixel Camera
    Wei, Ziran
    Zhang, Jianlin
    Xu, Zhiyong
    Liu, Yong
    Huang, Yongmei
    Fan, Xiangsuo
    IEEE PHOTONICS JOURNAL, 2019, 11 (01):
  • [2] Signal-to-noise ratio of single-pixel cameras based on photodiodes
    Jauregui-Sanchez, Y.
    Clemente, P.
    Latorre-Carmona, P.
    Tajahuerce, E.
    Lancis, J.
    APPLIED OPTICS, 2018, 57 (07) : B67 - B73
  • [3] Improving the signal-to-noise ratio of single-pixel imaging using digital microscanning
    Sun, Ming-Jie
    Edgar, Matthew P.
    Phillips, David B.
    Gibson, Graham M.
    Padgett, Miles J.
    OPTICS EXPRESS, 2016, 24 (10): : 10476 - 10485
  • [4] Investigation of Single-Pixel Imaging in Signal-to-Noise Ratio and Its Development at Special Wavelength
    Zhao Haixiao
    Guo Yan
    Li Peiming
    Chen Binglin
    Sun Baoqing
    LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (10)
  • [5] Single photon counting 3D imaging implemented under signal-to-noise ratio less than one
    Yan, Kang
    Zhang Tongyi
    Li Lifei
    Biao, Wang
    Wei, Zhao
    ELEVENTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2019), 2019, 11209