Portable Dynamometer-Based Measurement of Pelvic Floor Muscle Force

被引:0
|
作者
El-Sayegh, Batoul [1 ,2 ]
Dumoulin, Chantale [2 ,3 ]
Ali, Mohamed [1 ,4 ]
Assaf, Hussein [1 ]
De Jong, Jacqueline [5 ]
Sawan, Mohamad [1 ,6 ,7 ]
Leduc-Primeau, Francois [1 ]
机构
[1] Polytech Montreal, Dept Elect Engn, Montreal, PQ H3T 1J4, Canada
[2] Inst Univ Geriatrie Montreal, Res Ctr, Montreal, PQ H3W 1W4, Canada
[3] Univ Montreal, Fac Med, Sch Rehabil, Montreal, PQ H3N 1X7, Canada
[4] Elect Res Inst, Dept Microelect, Cairo 12622, Egypt
[5] Physio SPArtos, Interlaken, Switzerland
[6] Westlake Univ, Sch Engn, Hangzhou 310024, Peoples R China
[7] Westlake Inst Adv Study, CenBRAIN Neurotech Ctr Excellence, Hangzhou 310024, Peoples R China
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Force measurement; pelvic floor muscle assessment; urinary incontinence; vaginal dynamometer; URINARY-INCONTINENCE; STRENGTH; WOMEN;
D O I
10.1109/JTEHM.2022.3223258
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: In attempts to improve the quality of life of women, continuous projects are sought between rehabilitation intervention and engineering. Using the knowledge of the pelvic floor muscle (PFM) physiology, assessment and training methods are developed to reduce lower urinary tract symptoms such as urinary incontinence. Therefore, this paper covers the design and implementation of a portable vaginal dynamometer. Methods: A PFM probe is designed, 3D printed, assembled, and tested in ten women to assess its acceptability and usability. The feedback from the usability study is used to optimize the PFM probe design. A vaginal dynamometer is developed based on the designed PFM probe, then tested for linearity, repeatability, hysteresis, noise and heat effect, and power consumption. The variability between the different produced PFM probe prototypes is evaluated. Results: Force measurements are made using a load cell. Wireless communication is performed through a Bluetooth low energy transceiver v5.0, with a corresponding interface on both computer and smartphone. The device operates at a 3.3V supply and achieves a power consumption of 49.5 mW in operating mode. Two PFM probe sizes are designed to accommodate different vaginal hiatus sizes, based on usability study feedback. The proposed system allows the physiotherapist to wirelessly monitor variation in pelvic floor muscle force during assessment and/or training. Discussion/Conclusion: The testing results showed that the newly designed system has the potential to measure the PFM function in functional conditions such as the standing position.
引用
收藏
页码:44 / 53
页数:10
相关论文
共 50 条
  • [1] A Dynamometer-based Wireless Pelvic Floor Muscle Force Monitoring
    El-Sayegh, Batoul
    Dumoulin, Chantal
    Ali, Mohamed
    Assaf, Hussein
    Sawan, Mohamad
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 6127 - 6130
  • [2] Muscle Strength Measurement of Pelvic Floor in Women by Vaginal Dynamometer
    Parezanovic-Ilic, Katarina
    Jevtic, Milorad
    Jeremic, Branislav
    Arsenijevic, Slobodan
    [J]. SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2009, 137 (9-10) : 511 - 517
  • [3] Development of a dynamometer for measuring the isometric force of the pelvic floor musculature
    Dumoulin, C
    Bourbonnais, D
    Lemieux, MC
    [J]. NEUROUROLOGY AND URODYNAMICS, 2003, 22 (07) : 648 - 653
  • [4] Multidirectional Pelvic Floor Muscle Strength Measurement
    Cristina S. Saleme
    Daniel N. Rocha
    Sara Del Vecchio
    Agnaldo L. Silva Filho
    Marcos Pinotti
    [J]. Annals of Biomedical Engineering, 2009, 37 : 1594 - 1600
  • [5] Multidirectional Pelvic Floor Muscle Strength Measurement
    Saleme, Cristina S.
    Rocha, Daniel N.
    Del Vecchio, Sara
    Silva Filho, Agnaldo L.
    Pinotti, Marcos
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (08) : 1594 - 1600
  • [6] Reliability and Diagnostic Accuracy of a New Vaginal Dynamometer to Measure Pelvic Floor Muscle Strength
    Romero-Culleres, Georgia
    Pena-Pitarch, Esteban
    Jane-Feixas, Cecilia
    Vilaseca-Grane, Anna
    Montesinos, Jesus
    Arnau, Anna
    [J]. FEMALE PELVIC MEDICINE AND RECONSTRUCTIVE SURGERY, 2020, 26 (08): : 514 - 519
  • [7] DYNAMOMETER FOR DRILLING FORCE MEASUREMENT
    EHRENREI.E
    LENZ, E
    [J]. MECHANICAL ENGINEERING, 1971, 93 (07) : 48 - &
  • [8] Displacement-based dynamometer for milling force measurement
    Gomez, Michael F.
    Schmitz, Tony L.
    [J]. 47TH SME NORTH AMERICAN MANUFACTURING RESEARCH CONFERENCE (NAMRC 47), 2019, 34 : 867 - 875
  • [10] RELIABILITY AND VALIDITY OF A NEW VAGINAL DYNAMOMETER TO MEASURE PELVIC FLOOR MUSCLE STRENGTH IN WOMEN WITH URINARY INCONTINENCE
    Culleres, Romero G.
    Pitarch, Pena E.
    Feixas, Jane C.
    Grane, Vilaseca A.
    Bartes, Arnau A.
    Munoz, Montesinos J.
    Batalla, Sirvent G.
    Falguera, Tico N.
    Garcia, Dalmau C.
    Guardiola, Abenoza M.
    [J]. NEUROUROLOGY AND URODYNAMICS, 2013, 32 (06) : 658 - 659