Dual-frequency transmitter configuration for shallow surface electromagnetic detection

被引:0
|
作者
Liu, Weiyu [1 ]
Yu, Shengbao [1 ,2 ]
Zhang, Xinhao [1 ]
机构
[1] Jilin Univ, Coll Instrumentat & Elect Engn, Changchun 130026, Peoples R China
[2] Jilin Univ, Key Lab Geophys Explorat Equipment, Minist Educ, Changchun 130026, Peoples R China
关键词
shallow surface electromagnetic detection; frequency-domain electromagnetic detection; dual-frequency control strategy; LC series resonant; transmitter configuration; SYSTEM; POWER;
D O I
10.1088/1361-6501/ad1742
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In shallow surface electromagnetic detection, the square wave scheme is generally used in conventional transmission systems. Based on frequency-domain electromagnetic sounding theory, high-frequency measurement helps to improve vertical resolution. However, long grounded cable inductance produces severe reactive power suppression at high frequency transmission frequencies, which will reduce detection. To further improve detection accuracy and efficiency, a dual-frequency transmitter configuration is proposed in this article for shallow surface detection. The transmitter simultaneously powers two LC series resonant circuits for the detection of shallow and deep area. Dual-frequency control strategy is adopted, with both bridge arms being provided with constant switching frequency operation. According to the equivalent model of the transmission system, the control of the load branches is independent of each other. The LC series resonant circuit guarantees a wide passband to match long cable inductance that cannot be accurately estimated in advance. Simulations and experimental tests were carried out using this transmitter configuration and control technique. The simulation and experimental results are in general agreement, verifying the feasibility and effectiveness of the proposed dual-band transmitter configuration.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Dual-frequency electromagnetic confinement of liquid aluminum
    Li, SM
    Liu, L
    Li, JS
    Hao, QT
    Fu, HZ
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2005, 166 (03) : 449 - 454
  • [2] Study on the Dual-Frequency Excited Electromagnetic Flowmeter
    Liu, Tiejun
    Chen, Yinjia
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 571 - 575
  • [3] Research on the dual-frequency electromagnetic shaping of liquid metal
    Li, SM
    Li, JS
    Hao, QT
    Kou, HC
    Li, HG
    Fu, HZ
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2003, 137 (1-3) : 204 - 207
  • [4] Dual-frequency electromagnetic shaping process of liquid metal
    2001, Rare Metals Materials and Engineering Press (30):
  • [5] Dual-frequency electromagnetic shaping process of liquid metal
    Li, SM
    Hao, QT
    Li, JS
    Kou, HC
    Fu, HZ
    Jia, J
    Guo, JJ
    RARE METAL MATERIALS AND ENGINEERING, 2001, 30 (06) : 418 - 421
  • [6] An array transmitter for dual-frequency contrast enhanced intravascular ultrasound imaging
    Wang, Zhuochen
    Ma, Jianguo
    Jiang, Xiaoning
    Martin, Karl Heath
    Dayton, Paul A.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2104 - 2107
  • [7] Features of the Dual-Frequency Acoustic Signal Velocity in the Shallow Sea
    Korzhyk, Olekcii
    Didkovskyi, Vitalii
    Kurdiuk, Sergii
    Pavlenko, Olha
    ROMANIAN JOURNAL OF ACOUSTICS AND VIBRATION, 2019, 16 (02): : 96 - 105
  • [8] Dual-frequency chirp imaging for contrast detection
    Cheng, Chih-Hao
    Shen, Che-Chou
    Yeh, Chih-Kuang
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09): : 2767 - 2778
  • [9] Dual-Frequency Oil Spill Detection Algorithm
    Hammoud, Bilal
    Mazeh, Fatima
    Jomaa, Kassem
    Ayad, Hussam
    Ndagijimana, Fabien
    Faour, Ghaleb
    Jomaah, Jalal
    2017 COMPUTING AND ELECTROMAGNETICS INTERNATIONAL WORKSHOP (CEM'17), 2017, : 27 - 28
  • [10] Application of the dual-frequency ultrasonometer for osteoporosis detection
    Sarvazyan, Armen
    Tatarinov, Alexey
    Egorov, Vladimir
    Airapetian, Souren
    Kurtenok, Victor
    Gatt, Charles J., Jr.
    ULTRASONICS, 2009, 49 (03) : 331 - 337