Capacity and operation optimization of a low-temperature nuclear heating system considering heat storage

被引:9
|
作者
Liu, Weiqi [1 ]
Sun, Zhiyong [2 ]
Liu, Xingmin [2 ]
Li, Gen [3 ]
Wang, Jinshi [1 ]
Yan, Junjie [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
[2] China Inst Atom Energy, Beijing 102413, Peoples R China
[3] South China Univ Technol, Sch Elect Power Engn, Guangzhou, Peoples R China
关键词
Nuclear heating system; Heat storage; Annual cost; Operation strategy; Optimal capacity and operation; THERMAL-ENERGY STORAGE; COGENERATION; REACTOR; LOAD; SAFE; SMR; TRANSIENT; OPTIONS; PLANTS; COST;
D O I
10.1016/j.pnucene.2023.104717
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Integrating heat storage devices with the pool-type low-temperature heating reactor (PLTHR) can improve the flexibility of PLTHR for load following. A novel low-temperature nuclear heating system (HST-NHS) is proposed, which combines the DHR-400 heating reactor system, a heat storage tank (HST), and a gas boiler (GB) to achieve real-time matching between heating supply and demand. A mixed integer nonlinear programming (MINLP) optimization model with the annual cost (AC) as the optimization objective is established. An operation strategy that considers the device priority is proposed. The capacity and operation of HST-NHS are simultaneously optimized using the CPLEX solver. The optimization results indicate that an HST with a rated capacity of 1324.14 MWh and a GB with a rated capacity of 201.69 MW can provide the operational flexibility needed for the HST-NHS throughout the heating period. When compared with comparison schemes 1 (DHR-400 and HST), 2 (DHR-400 and GB), and 3 (pure gas boiler heating system), HST-NHS achieves significant annual cost savings. Finally, a sensitivity analysis of device price and fuel price is conducted, revealing that the unit price of the DHR-400 heating reactor system and natural gas price are the main factors affecting the AC and dynamic payback period (DPP) of HST-NHS. This work offers theoretical guidance for the subsequent engineering application of the DHR-400 heating reactor system.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Capacity Configuration and Operation Optimization of a Low-Temperature Reactor Nuclear Heating System with Heat Storage
    Liu, Weiqi
    Wang, Jinshi
    Xue, Kai
    Sun, Zhiyong
    Liu, Xingmin
    Li, Gen
    Yan, Junjie
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (04): : 213 - 220
  • [2] The optimalization of the heat pump operation in low-temperature heating systems
    Petrás, D
    Matej, P
    ENERGY FOR BUILDINGS, 2004, : 346 - 351
  • [3] Low-temperature heat capacity of pentlandite
    Berezovskii, GA
    Drebushchak, VA
    Kravchenko, TA
    AMERICAN MINERALOGIST, 2001, 86 (10) : 1312 - 1313
  • [4] Low-temperature heat capacity of ZnTe
    Gavrichev, KS
    Guskov, VN
    Greenberg, JH
    Feltgen, T
    Fiederle, M
    Benz, KW
    JOURNAL OF CHEMICAL THERMODYNAMICS, 2002, 34 (12): : 2041 - 2047
  • [5] LOW-TEMPERATURE HEAT CAPACITY OF AZURITE
    FORSTAT, H
    TAYLOR, G
    KING, BR
    JOURNAL OF CHEMICAL PHYSICS, 1959, 31 (04): : 929 - 931
  • [6] LOW-TEMPERATURE HEAT CAPACITY OF TETRABUTYLGERMANE
    SHAULOV, YK
    YAKUBOV, ES
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY,USSR, 1971, 45 (01): : 107 - &
  • [7] Low-temperature heat capacity of pentlandite
    Berezovskii, G.A.
    Drebushchak, V.A.
    Kravchenko, T.A.
    2001, Mineralogical Society of America (86)
  • [8] SEASONAL STORAGE OF LOW-TEMPERATURE HEAT
    FISCH, N
    BRENNSTOFF-WARME-KRAFT, 1989, 41 (11): : 505 - 510
  • [9] Low-Temperature Nuclear Heating Plants.
    Kulig, Maciej
    Podpora, Jan
    Przeglad Elektrotechniczny, 1979, 55 (03): : 129 - 132
  • [10] Optimization of the configuration and flexible operation of the pipe-embedded floor heating with low-temperature district heating
    Yang, Xiaochen
    Pan, Li
    Guan, Wenze
    Tian, Zhe
    Wang, Jing
    Zhang, Chen
    ENERGY AND BUILDINGS, 2022, 269