Implantable cardioverter defibrillator lead performance: A systematic review and individual patient data Meta-analysis

被引:3
|
作者
Giacopelli, Daniele [1 ,2 ,8 ]
Azzolina, Danila [3 ]
Comoretto, Rosanna Irene [4 ]
Quartieri, Fabio [5 ]
Rovaris, Giovanni [6 ]
Schillaci, Vincenzo [7 ]
Gargaro, Alessio [2 ]
Gregori, Dario [1 ]
机构
[1] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Padua, Italy
[2] Biotronik Italia, Clin Unit, Milan, Italy
[3] Univ Ferrara, Dept Environm & Prevent Sci, Ferrara, Italy
[4] Univ Torino, Dept Publ Hlth & Pediat, Turin, Italy
[5] Arcispedale Santa Maria Nuova, Dept Cardiol, Reggio Emilia, Italy
[6] Osped San Gerardo, Dept Cardiol, Monza, Italy
[7] Clin Montevergine, Electrophysiol Unit, Mercogliano, Italy
[8] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Via Giustiniani 2, I-35128 Padua, Italy
关键词
Implantable cardioverter-defibrillator; Post market surveillance; ICD leads; Failure; meta; -analysis; LONG-TERM PERFORMANCE; SPRINT FIDELIS; FAILURE RATES; BIOTRONIK LINOX; RIATA; RISK; SURVIVAL; SURVEILLANCE; MULTICENTER; DYSFUNCTION;
D O I
10.1016/j.ijcard.2022.11.048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Reliable post-approval surveillance of implantable cardioverter-defibrillator (ICD) lead performance remains a challenge. In the past, two ICD leads were recalled due to a high frequency of failures. In this meta -analysis, we sought to provide a combined estimate of failure-free rate for ICD leads by reconstructing individual patient data from published Kaplan-Meier (KM) curves and to investigate whether estimates could be influenced by the characteristics of the study.Methods: Observational studies assessing failure-free estimates of transvenous ICD leads with KM method, were identified through a systematic search up to November 2021.Results: Forty-four studies were eligible that included 41,870 (63.1%) non-recalled leads and 24,493 (36.9%) recalled leads. The 8-year cumulative failure-free rate was 94.1% (CI, 93.6% -94.6%) for contemporary non-recalled leads and 81.2% (80.3% -82.0%) for recalled leads (hazard ratio [HR], 3.15 [2.85-3.47], p < 0.001). Failure-free rate was lower in single-center studies in both the non-recalled (HR, 0.28 [0.15-0.51], p < 0.001) and recalled (HR, 0.54 [0.33-0.88], p = 0.014) group compared with multicenter studies. Similarly, estimates were significantly lower in small (i.e. extracted KM curve with <312 leads) versus large studies (HR non-recalled group, 0.54 [CI, 0.33-0.89], p = 0.015; HR recalled group, 0.62 [CI, 0.43-0.89], p = 0.009). Conclusions: In this meta-analysis including >66,000 leads, we provide pooled survival curves that may play a role in generating evidence-based standards for assessing clinically acceptable failure rates for ICD leads. Lead performance was underestimated with single-center and small-sized studies; multicenter studies remain the main tool to reliably conduct post-market surveillance of ICD leads.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [1] Implantable cardioverter defibrillator in nonischemic cardiomyopathy: A systematic review and meta-analysis
    Khan, Safi U.
    Ghimire, Subash
    Talluri, Swapna
    Rahman, Hammad
    Khan, Muhammad U.
    Nasir, Fahad
    Kaluski, Edo
    JOURNAL OF ARRHYTHMIA, 2018, 34 (01) : 4 - 10
  • [2] Outcome of implantable cardioverter defibrillator in cardiac sarcoidosis: a systematic review and meta-analysis
    Halawa, Ahmad
    Jain, Rahul
    Turagam, Mohit K.
    Kusumoto, Fred M.
    Woldu, Henok G.
    Gautam, Sandeep
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 58 (02) : 233 - 242
  • [3] Outcome of implantable cardioverter defibrillator in cardiac sarcoidosis: a systematic review and meta-analysis
    Ahmad Halawa
    Rahul Jain
    Mohit K. Turagam
    Fred M. Kusumoto
    Henok G. Woldu
    Sandeep Gautam
    Journal of Interventional Cardiac Electrophysiology, 2020, 58 : 233 - 242
  • [4] Subcutaneous Implantable Cardioverter Defibrillator in Hypertrophic Cardiomyopathy: A Systematic Review and Meta-Analysis
    Oliveira, Vinicius M.
    Oliveira, Izadora C.
    Menezes Junior, Antonio da Silva
    CIRCULATION, 2023, 148
  • [5] The prevalence of depression in patients living with implantable cardioverter defibrillator: a systematic review and meta-analysis
    Oshvandi, Khodayar
    Khatiban, Mahnaz
    Ghanei Gheshlagh, Reza
    Razavi, Mohammadreza
    IRISH JOURNAL OF MEDICAL SCIENCE, 2020, 189 (04) : 1243 - 1252
  • [6] The prevalence of depression in patients living with implantable cardioverter defibrillator: a systematic review and meta-analysis
    Khodayar Oshvandi
    Mahnaz Khatiban
    Reza Ghanei Gheshlagh
    Mohammadreza Razavi
    Irish Journal of Medical Science (1971 -), 2020, 189 : 1243 - 1252
  • [7] Implantable cardioverter defibrillator in old age patients with cardiomyopathy : a meta-analysis and systematic review
    Tokavanich, N.
    Prasitlumkum, N.
    Kittipibul, V
    Mongkonsritragoon, W.
    Ariyachaipanich, A.
    EUROPEAN HEART JOURNAL, 2020, 41 : 65 - 66
  • [8] Right ventricular apical versus non-apical implantable cardioverter defibrillator lead: A systematic review and meta-analysis
    Garg, Jalaj
    Chaudhary, Rahul
    Shah, Neeraj
    Palaniswamy, Chandrasekar
    Bozorgnia, Babak
    Nazir, Talha
    Natale, Andrea
    Kutyifa, Valentina
    JOURNAL OF ELECTROCARDIOLOGY, 2017, 50 (05) : 591 - 597
  • [9] Transvenous Implantable Cardioverter-Defibrillator (ICD) Lead Performance: A Meta-Analysis of Observational Studies
    Providencia, Rui
    Kramer, Daniel B.
    Pimenta, Dominic
    Babu, Girish G.
    Hatfield, Laura A.
    Ioannou, Adam
    Novak, Jan
    Hauser, Robert G.
    Lambiase, Pier D.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2015, 4 (11):
  • [10] Treatment Modalities for the Prevention of Implantable Cardioverter Defibrillator Shocks: Systematic Review and Network Meta-Analysis
    Knijnik, Leonardo M.
    Kaplan, Michael W.
    Rivera, Manuel
    Fernandes, Gilson
    Cardoso, Rhanderson
    Fernandes, Amanda
    Lambrakos, Litsa K.
    Mitrani, Raul
    Goldberger, Jeffrey J.
    CIRCULATION, 2019, 140