Non-invasive accurate time resolved inverse battery calorimetry

被引:0
|
作者
Chalise, Divya [1 ,2 ]
Saxon, Aron [3 ]
Zeng, Yuqiang [2 ]
Srinivasan, Venkat [4 ]
Lubner, Sean [1 ,5 ]
Keyser, Matthew [3 ]
Prasher, Ravi S. [1 ,2 ]
机构
[1] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
[2] Lawrence Berkeley Natl Lab, Energy Technol Area, 1 Cyclotron Rd, Berkeley, CA 94720 USA
[3] Natl Renewable Energy Lab, Golden, CO 80401 USA
[4] Argonne Natl Lab, Lemont, IL 60439 USA
[5] Boston Univ, Dept Mech Engn, Boston, MA 02215 USA
关键词
LITHIUM-ION BATTERIES; HEAT-GENERATION; THERMAL RUNAWAY; THERMOPHYSICAL PROPERTIES; TEMPERATURE; CELL; RATES;
D O I
10.1016/j.ensm.2023.102810
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Precise knowledge of the battery heat generation rate and the internal temperature rise allows accurate thermal regulation required for enabling fast charging while minimizing side reactions and avoiding thermal runaway. With the necessity of high energy density, the size of batteries is constantly increasing. Because of poor thermal conduction, the thermal lag in large batteries is significant resulting in a considerable temperature gradient within the cell. Existing calorimetry methods only account for the external heat flow measurement and the external temperature rise and therefore cannot account for the thermal lag inside the cell. Additionally, with these methods, the temporal (time-resolved) information of the heat generation rate is compromised, which makes observation and attribution of electro- chemical-thermal signatures impossible. As a potential solution, various intrusive techniques such as embedded thermal sensors have been proposed in the literature. However, these techniques are limited in scope. To enable accurate measurement of time-resolved heat flux measurement in commercial batteries, we instead propose a new battery calorimetry approach by combining state-of-the-art commercial calorimetry with an inverse heat transfer algorithm. This inverse calorimetry is completely non-intrusive with no change to commercial calorimeters. The inverse calorimetry reduces the error in heat generation rate to within 10% of the actual heat generation rate compared to 50% from the lumped capacitance method (best existing method). This method enables time resolved observation of electrochemical-thermal signatures such as a negative heat generation rate due to entropy change, which could not be observed from existing calorimetry methods.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Response to Value of indirect calorimetry in non-invasive ventilation
    Siirala, Waltteri
    Noponen, Tommi
    Olkkola, Klaus T.
    Vuori, Arno
    Koivisto, Mari
    Hurme, Saija
    Aantaa, Riku
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (01) : 101 - 102
  • [2] Response to Value of indirect calorimetry in non-invasive ventilation
    Waltteri Siirala
    Tommi Noponen
    Klaus T. Olkkola
    Arno Vuori
    Mari Koivisto
    Saija Hurme
    Riku Aantaa
    Journal of Clinical Monitoring and Computing, 2013, 27 : 101 - 102
  • [3] Non-invasive Raman spectroscopy for time-resolved in-line lipidomics
    Wieland, Karin
    Masri, Mahmoud
    von Poschinger, Jeremy
    Brueck, Thomas
    Haisch, Christoph
    RSC ADVANCES, 2021, 11 (46) : 28565 - 28572
  • [4] Non-invasive Monitoring of Hepatic Oxygenation Using Time-Resolved Spectroscopy
    Yasuda, Tomotsugu
    Yamaguchi, Keiji
    Futatsuki, Takahiro
    Furubeppu, Hiroaki
    Nakahara, Mayumi
    Eguchi, Tomohiro
    Miyamoto, Shotaro
    Madokoro, Yutaro
    Terada, Shinsaku
    Nakamura, Kentaro
    Harada, Hiroki
    Junichiro, Taniguchi
    Yanagimoto, Kosuke
    Kakihana, Yasuyuki
    OXYGEN TRANSPORT TO TISSUE XXXVII, 2016, 876 : 407 - 412
  • [5] Non-invasive depth profiling by space and time-resolved Raman spectroscopy
    Sundarajoo, Shankaran
    Izake, Emad L.
    Olds, William
    Cletus, Biju
    Jaatinen, Esa
    Fredericks, Peter M.
    JOURNAL OF RAMAN SPECTROSCOPY, 2013, 44 (07) : 949 - 956
  • [6] An inverse method for non-invasive viscosity measurements
    Fullana, J. -M.
    Dispot, N.
    Flaud, P.
    Rossi, M.
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2007, 38 (01): : 79 - 92
  • [7] NON-INVASIVE INVERSE PROBLEM IN CIVIL ENGINEERING
    Havelka, Jan
    Sykora, Jan
    Kucerova, Anna
    NMM 2017 - NANO & MACRO MECHANICS 2017, 2017, 13 : 43 - 48
  • [8] Non-invasive carbon monoxide measurement is not accurate
    O'Malley, Gerald F.
    ANNALS OF EMERGENCY MEDICINE, 2006, 48 (04) : 477 - 478
  • [9] Time of non-invasive ventilation
    Stefano Nava
    Paolo Navalesi
    Giorgio Conti
    Intensive Care Medicine, 2006, 32 : 361 - 370
  • [10] Time of non-invasive ventilation
    Nava, S
    Navalesi, P
    Conti, G
    INTENSIVE CARE MEDICINE, 2006, 32 (03) : 361 - 370