Vibration sensitivity minimization of an ultra-stable optical reference cavity based on orthogonal experimental design

被引:0
|
作者
Gao, Jing [1 ,2 ]
Jiao, Dongdong [1 ,2 ]
Zhang, Linbo [1 ,2 ]
Xu, Guanjun [1 ,2 ]
Deng, Xue [1 ,2 ]
Zang, Qi [1 ,2 ]
Yang, Honglei [3 ]
Dong, Ruifang [1 ,2 ]
Liu, Tao [1 ,2 ]
Zhang, Shougang [1 ,2 ]
机构
[1] Chinese Acad Sci, Natl Time Serv Ctr, 3 East Shuyuan Rd, Xian 710600, Peoples R China
[2] Chinese Acad Sci, Key Lab Time & Frequency Stand, 3 East Shuyuan Rd, Xian 710600, Peoples R China
[3] Beijing Inst Radio Metrol & Measurement, Sci & Technol Metrol & Calibrat Lab, 50 Yongding Rd, Beijing 100854, Peoples R China
来源
OPEN PHYSICS | 2023年 / 21卷 / 01期
关键词
ultra-stable optical reference cavity; optimization; vibration sensitivity; orthogonal experimental design; ultra-stable laser; FREQUENCY; INSTABILITY; STABILIZATION; LASERS; NOISE;
D O I
10.1515/phys-2022-0269
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The ultra-stable optical reference cavity (USORC) is a key element for a variety of applications. In this work, based on the orthogonal experimental design method, we study the vibration sensitivity optimization of a classical USORC with a 100 mm length. According to a test of 4 levels and 3 factors, the L (16) (4(3)) orthogonal table is established to design orthogonal experiments. The vibration sensitivities under different parameters are simulated and analyzed. The vibration sensitivities in three directions of the USORC are used as three single-object values, and the normalized sum of the three vibration sensitivities is selected as comprehensive object values. Through the range analysis of the object values, the influence degrees of the parameters on the three single objects and the comprehensive object are determined. The optimal parameter combination schemes are obtained by using the comprehensive balance method and the comprehensive evaluation method, respectively. Based on the corresponding fractional frequency stability of ultra-stable lasers, the final optimal parameter combination scheme A1B3C3 is determined and verified. This work is the first to use an orthogonal experimental design method to optimize vibration sensitivities, providing an approach to vibration sensitivities optimization and is also beneficial for the vibration sensitivity design of a transportable USORC.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Active vibration isolation of ultra-stable optical reference cavity of space optical clock
    He, Keda
    Li, Qing
    Liu, Lei
    Yang, Hongjie
    AEROSPACE SCIENCE AND TECHNOLOGY, 2021, 112
  • [2] ULTRA-STABLE OPTICAL CAVITY: DESIGN AND EXPERIMENTS
    Millo, J.
    Bize, S.
    English, E. M. L.
    Lemonde, P.
    Santarelli, G.
    PROCEEDINGS OF THE 7TH SYMPOSIUM FREQUENCY STANDARDS AND METROLOGY, 2009, : 393 - 397
  • [3] Thermal Analysis Method for Optical Reference Cavity of Ultra-Stable Laser Based on Transfer Function
    Deng Jiuchang
    Xie Yong
    Meng Lingqiang
    Bian Wei
    Yin Xiongfei
    Jia Jianjun
    ACTA OPTICA SINICA, 2023, 43 (14)
  • [4] AN ULTRA-STABLE OPTICAL FREQUENCY REFERENCE FOR SPACE
    Schuldt, T.
    Doringshoff, K.
    Kovalchuk, E.
    Pahl, J.
    Gohlke, M.
    Weise, D.
    Johann, U.
    Peters, A.
    Braxmaier, C.
    INTERNATIONAL CONFERENCE ON SPACE OPTICS-ICSO 2014, 2014, 10563
  • [5] Zero-crossing temperature of ultra-stable optical reference cavity measured by optical transition spectrum
    Li Ting
    Lu Xiao-Tong
    Zhou Chi-Hua
    Yin Mo-Juan
    Wang Ye-Bing
    Chang Hong
    ACTA PHYSICA SINICA, 2021, 70 (07)
  • [6] Study on the effect of ULE rings on the vibration sensitivity of horizontal ultra-stable optical cavities
    Xu, G.
    Zhang, L.
    Chen, L.
    Jiao, D.
    Liu, J.
    Jiang, C.
    Zhang, X.
    Zang, Q.
    Wang, X.
    Dong, R.
    Liu, Tao
    2018 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2018, : 389 - 391
  • [7] An Ultra-Stable Optical Frequency Reference for Space Applications
    Schuldt, Thilo
    Keetman, Anja
    Doeringshoff, Klaus
    Reggentin, Matthias
    Kovalchuk, Evgeny
    Nagel, Moritz
    Gohlke, Martin
    Johann, Ulrich
    Weise, Dennis
    Peters, Achim
    Braxmaier, Claus
    2012 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2012, : 554 - 558
  • [8] Temperature-compensated ultra-stable optical cavity with re-entrant design
    Chang, Jialu
    Wu, Qiyue
    Wang, Zhiyuan
    Zhang, Jingxuan
    Wei, Qiang
    Chen, Xiaoxu
    Lu, Zehuang
    Zhang, Jie
    Optics Letters, 2025, 50 (03) : 868 - 871
  • [9] Prototype of an ultra-stable optical cavity for space applications.
    Argence, B.
    Prevost, E.
    Leveque, T.
    Le Goff, R.
    Bize, S.
    Lemonde, P.
    Santarelli, G.
    OPTICS EXPRESS, 2012, 20 (23): : 25409 - 25420
  • [10] Digital Control of Residual Amplitude Modulation for Ultra-Stable Optical Cavity
    Talla, S. F. Tetsing
    Millo, J.
    Denis, S.
    Lacroute, C.
    Goavec-Merou, G.
    Rubiola, E.
    Kersale, Y.
    2020 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF FERROELECTRICS (IFCS-ISAF), 2020,