An investigation of factors affecting high-precision Sr isotope analyses (87Sr/86Sr and δ88/86Sr) by MC-ICP-MS

被引:4
|
作者
Wang, Jiuyuan [1 ,2 ]
Di, Yankun [3 ]
Asael, Dan [1 ]
Planavsky, Noah J. [1 ,2 ]
Tarhan, Lidya G. [1 ]
机构
[1] Yale Univ, Dept Earth & Planetary Sci, New Haven, CT 06511 USA
[2] Yale Univ, Yale Ctr Nat Carbon Capture, New Haven, CT 06511 USA
[3] Australian Natl Univ, Res Sch Earth Sci, Acton, ACT 2601, Australia
关键词
CONCOMITANT ELEMENTS; RATIO MEASUREMENTS; MASS-SPECTROMETRY; PLASMA; STRONTIUM; FRACTIONATION; ACCURACY; SR-87/SR-86; MATRIX; DELTA-SR-88/86;
D O I
10.1016/j.chemgeo.2023.121365
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The stable strontium (Sr) isotope system is being increasingly utilized to move forward our understanding of environmental, geological, and cosmological processes. Two analytical techniques are commonly used to mea-sure stable Sr isotopes: 1) double-spike thermal ionization mass spectrometry (DS-TIMS) and 2) Zr-doped sample -standard bracketing multi-collector inductively coupled plasma mass spectrometry (Zr-doped SSB via MC-ICP-MS). Relative to DS-TIMS, Zr-doped SSB via MC-ICP-MS allows simultaneous determination of both 87Sr/86Sr and 88Sr/86Sr ratios, increasing measurement efficiency and sample throughput. However, several factors limit the analytical precision and accuracy of this technique, including matrix effects and potential intra-and inter -session offsets of measured isotope ratios. In this study, we evaluate potential causes for the observed offsets. We performed a series of experiments to assess the effect of different solution matrices and sources of contamination on Sr isotope measurements and to explore potential underlying mechanisms. Our tests show that incomplete Sr recovery during chromatographic separation, mismatches of Sr and Zr concentrations and acid molarity between samples and bracketing standards, and cation contamination all affect the precision and ac-curacy of Sr isotope measurements. We present evidence that analyses using our recommended updated prep-aration procedure for Zr-doped SSB via MC-ICP-MS can achieve a long-term reproducibility (2 sigma SD: 87Sr/86Sr = +/- 0.000015 and delta 88/86Sr = +/- 0.03 parts per thousand) comparable to that of DS-TIMS.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Determination of 87Sr/86Sr and δ88/86Sr ratios in plant materials using MC-ICP-MS
    Liu, Hou-Chun
    Chung, Chuan-Hsiung
    You, Chen-Feng
    Chiang, Yi-Hsuan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (02) : 387 - 397
  • [2] Determination of 87Sr/86Sr and δ88/86Sr ratios in plant materials using MC-ICP-MS
    Hou-Chun Liu
    Chuan-Hsiung Chung
    Chen-Feng You
    Yi-Hsuan Chiang
    [J]. Analytical and Bioanalytical Chemistry, 2016, 408 : 387 - 397
  • [3] Testing miniaturized extraction chromatography protocols for combined 87Sr/86Sr and δ88/86Sr analyses of pore water by MC-ICP-MS
    Argentino, Claudio
    Lugli, Federico
    Cipriani, Anna
    Panieri, Giuliana
    [J]. LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2021, 19 (06): : 431 - 440
  • [4] Precise measurement of stable (δ88/86Sr) and radiogenic (87Sr/86Sr) strontium isotope ratios in geological standard reference materials using MC-ICP-MS
    MA JinLong
    WEI GangJian
    LIU Ying
    REN ZhongYuan
    XU YiGang
    YANG YongHong
    [J]. Science Bulletin, 2013, (25) : 3111 - 3118
  • [5] Precise measurement of stable (δ88/86Sr) and radiogenic (87Sr/86Sr) strontium isotope ratios in geological standard reference materials using MC-ICP-MS
    Ma JinLong
    Wei GangJian
    Liu Ying
    Ren ZhongYuan
    Xu YiGang
    Yang YongHong
    [J]. CHINESE SCIENCE BULLETIN, 2013, 58 (25): : 3111 - 3118
  • [6] Accuracy and precision of 88Sr/86Sr and 87Sr/86Sr measurements by MC-ICPMS compromised by high barium concentrations
    Scher, Howie D.
    Griffith, Elizabeth M.
    Buckley, Wayne P., Jr.
    [J]. GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2014, 15 (02): : 499 - 508
  • [7] Ocean Sr-budget from paired δ88/86Sr and 87Sr/86Sr*-ratios
    Krabbenhoeft, A.
    Eisenhauer, A.
    Vollstaedt, H.
    Augustin, N.
    Fietzke, J.
    Liebetrau, V.
    Peucker-Ehrenbrink, B.
    Nolte, N.
    Hansen, B. T.
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A694 - A694
  • [8] High throughput method for Sr extraction from variable matrix waters and 87Sr/86Sr isotope analysis by MC-ICP-MS
    Wall, Andrew J.
    Capo, Rosemary C.
    Stewart, Brian W.
    Phan, Thai T.
    Jain, Jinesh C.
    Hakala, J. Alexandra
    Guthrie, George D.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (08) : 1338 - 1344
  • [10] A Method for 87Sr/86Sr Isotope Ratio Determination in Biogenic Apatite by MC-ICP-MS Using the SSB Technique
    Kasyanova, A., V
    Streletskaya, M., V
    Chervyakovskaya, M., V
    Kiseleva, D., V
    [J]. PHYSICS, TECHNOLOGIES AND INNOVATION (PTI-2019), 2019, 2174