Advancement in the Cuffless and Noninvasive Measurement of Blood Pressure: A Review of the Literature and Open Challenges

被引:12
|
作者
Mamun, Mohammad Mahbubur Rahman Khan [1 ]
Sherif, Ahmed [2 ]
机构
[1] Tennessee Technol Univ, Dept Elect & Comp Engn, Cookeville, TN 38505 USA
[2] Univ Southern Mississippi, Sch Comp Sci & Comp Engn, Hattiesburg, MS 39406 USA
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 01期
关键词
cuffless blood pressure; hypertension; photoplethysmography; electrocardiogram; machine learning; deep learning;
D O I
10.3390/bioengineering10010027
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Hypertension is a chronic condition that is one of the prominent reasons behind cardiovascular disease, brain stroke, and organ failure. Left unnoticed and untreated, the deterioration in a health condition could even result in mortality. If it can be detected early, with proper treatment, undesirable outcomes can be avoided. Until now, the gold standard is the invasive way of measuring blood pressure (BP) using a catheter. Additionally, the cuff-based and noninvasive methods are too cumbersome or inconvenient for frequent measurement of BP. With the advancement of sensor technology, signal processing techniques, and machine learning algorithms, researchers are trying to find the perfect relationships between biomedical signals and changes in BP. This paper is a literature review of the studies conducted on the cuffless noninvasive measurement of BP using biomedical signals. Relevant articles were selected using specific criteria, then traditional techniques for BP measurement were discussed along with a motivation for cuffless measurement use of biomedical signals and machine learning algorithms. The review focused on the progression of different noninvasive cuffless techniques rather than comparing performance among different studies. The literature survey concluded that the use of deep learning proved to be the most accurate among all the cuffless measurement techniques. On the other side, this accuracy has several disadvantages, such as lack of interpretability, computationally extensive, standard validation protocol, and lack of collaboration with health professionals. Additionally, the continuing work by researchers is progressing with a potential solution for these challenges. Finally, future research directions have been provided to encounter the challenges.
引用
收藏
页数:28
相关论文
共 50 条
  • [1] Noninvasive Cuffless Blood Pressure Measurement by Vascular Transit Time
    Shukla, Satya Narayan
    Kakwani, Karan
    Patra, Amit
    Lahkar, Bipin Kumar
    Gupta, Vivek Kumar
    Jayakrishna, Alwar
    Vashisht, Puneet
    Sreekanth, Induja
    2015 28TH INTERNATIONAL CONFERENCE ON VLSI DESIGN (VLSID), 2015, : 535 - 540
  • [2] Noninvasive Accelerometric Approach for Cuffless Continuous Blood Pressure Measurement
    Das, Mousumi
    Choudhary, Tilendra
    Sharma, L. N.
    Bhuyan, M. K.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [3] Cuffless Blood Pressure Measurement
    Mukkamala, Ramakrishna
    Stergiou, George S.
    Avolio, Alberto P.
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2022, 24 : 203 - 230
  • [4] Noninvasive and cuffless measurements of blood pressure for telemedicine
    Chan, KW
    Hung, K
    Zhang, YT
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3592 - 3593
  • [5] Noninvasive Cuffless Estimation of Blood Pressure using Photoplethysmography without Electrocardiograph Measurement
    Samria, Rohan
    Jain, Ridhi
    Jha, Ankita
    Saini, Sandeep
    Chowdhury, Shubhajit Roy
    2014 IEEE REGION 10 SYMPOSIUM, 2014, : 254 - 257
  • [6] Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals
    Mukkamala, Ramakrishna
    Yavarimanesh, Mohammad
    Natarajan, Keerthana
    Hahn, Jin-Oh
    Kyriakoulis, Konstantinos G.
    Avolio, Alberto P.
    Stergiou, George S.
    HYPERTENSION, 2021, 78 (05) : 1161 - 1167
  • [7] A Literature Review on Current and Proposed Technologies of Noninvasive Blood Pressure Measurement
    Mukherjee, Ramtanu
    Ghosh, Sanchita
    Gupta, Bharat
    Chakravarty, Tapas
    TELEMEDICINE AND E-HEALTH, 2018, 24 (03) : 185 - 193
  • [8] Advancement on Automatic Blood Pressure Measurement Using Auscultatory Method: A Literature Review
    Naufal, Dziban
    Rajab, Tati Latifah Erawati
    Setiawan, Agung Wahyu
    PROCEEDING OF 2019 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS (ICEEI), 2019, : 631 - 637
  • [9] Development of System for Noninvasive Cuffless Estimation of Blood Pressure
    Anisimov, A. A.
    Ananyeva, A.
    PROCEEDINGS OF THE 2014 IEEE NW RUSSIA YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING CONFERENCE (ELCONRUSNW), 2014, : 19 - 22
  • [10] Cuffless Blood Pressure Monitoring Promises and Challenges
    Pandit, Jay A.
    Lores, Enrique
    Batlle, Daniel
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2020, 15 (10): : 1531 - 1538