Recent advances in fabrication of smart dressings for real-time monitoring of pH in chronic wounds-a review

被引:6
|
作者
Sadeghi-Avalshahr, Ali Reza [1 ,3 ]
Molavi, Amir Mahdi [1 ,2 ]
Nokhasteh, Samira [1 ]
Harati, Zahra [1 ]
机构
[1] Iranian Acad Ctr Educ Culture & Res ACECR, Dept Mat Res, Khorasan Razavi Branch, Mashhad, Razavi Khorasan, Iran
[2] Tarbiat Modares Univ, Mat Engn Dept, Tehran, Iran
[3] Mashhad Univ Med Sci, Fac Med Sci, Dept Tissue Engn, Mashhad, Razavi Khorasan, Iran
关键词
pH sensor; Chronic wound; Smart dressing; Real-time monitoring; SENSOR; TEMPERATURE; ELECTROSPUN; MANAGEMENT; BANDAGE; ARRAY;
D O I
10.1007/s00289-022-04357-1
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Healing of wound involves a complex series of events in four overlapping phases, namely hemostasis, inflammation, proliferation, and remodeling. Non-healing or hard-to-heal wounds usually get stuck in inflammation phase. These categories of wounds are prone to infect via bacterial activities and biofilm formation. To avoid this, timely detection of infection is very important for proper management of wound and effective treatment. This could be achieved through continuous monitoring of pH in wound milieu. While the pH of intact skin is mostly in acidic region (4-6), this is turned to alkaline conditions (7-9) for chronic wounds. Recently, flexible optical and electrochemical pH sensors have been developed for this purpose, which are integrated in medical dressings and could be used as wearable products in medical field. Whenever designing a pH sensor, the most important factors, which should be considered, include biocompatibility, sensitivity, response time, accuracy and precision, storage life, reproducibility, photochemical stability, and cost. In this review, a relatively comprehensive study of the research conducted for design and fabrication of various optical and electrochemical pH sensors during the last five years has been presented.
引用
收藏
页码:5831 / 5859
页数:29
相关论文
共 50 条
  • [1] Recent advances in fabrication of smart dressings for real-time monitoring of pH in chronic wounds—a review
    Ali Reza Sadeghi-Avalshahr
    Amir Mahdi Molavi
    Samira Nokhasteh
    Zahra Harati
    Polymer Bulletin, 2023, 80 : 5831 - 5859
  • [2] Recent advances in biosensors for real time monitoring of pH, temperature, and oxygen in chronic wounds
    Youssef, Khaled
    Ullah, Asad
    Rezai, Pouya
    Hasan, Anwarul
    Amirfazli, Alidad
    MATERIALS TODAY BIO, 2023, 22
  • [3] Recent advances of hydrogels as smart dressings for diabetic wounds
    Wang, Xu
    Yang, Yuhan
    Zhao, Weifeng
    Zhu, Zhou
    Pei, Xibo
    JOURNAL OF MATERIALS CHEMISTRY B, 2024, 12 (05) : 1126 - 1148
  • [4] Preparation of porous alginate-based smart dressings used in real-time monitoring of pH in chronic wounds by evaluating two fabrication routes: freeze-drying vs. electrospinning
    Haghbin, Mahsa
    Sadeghi-Avalshahr, Alireza
    Hassanzadeh, Halimeh
    Moloodi, Ahmad
    Harati, Zahra
    JOURNAL OF POROUS MATERIALS, 2023, 30 (06) : 1953 - 1963
  • [5] Preparation of porous alginate-based smart dressings used in real-time monitoring of pH in chronic wounds by evaluating two fabrication routes: freeze-drying vs. electrospinning
    Mahsa Haghbin
    Alireza Sadeghi-Avalshahr
    Halimeh Hassanzadeh
    Ahmad Moloodi
    Zahra Harati
    Journal of Porous Materials, 2023, 30 : 1953 - 1963
  • [6] Nanocellulose composite wound dressings for real-time pH wound monitoring
    Eskilson, Olof
    Zattarin, Elisa
    Berglund, Linn
    Oksman, Kristiina
    Hanna, Kristina
    Rakar, Jonathan
    Sivler, Petter
    Skog, Marten
    Rinklake, Ivana
    Shamasha, Rozalin
    Sotra, Zeljana
    Starkenberg, Annika
    Oden, Magnus
    Wiman, Emanuel
    Khalaf, Hazem
    Bengtsson, Torbjorn
    Junker, Johan P. E.
    Selegard, Robert
    Bjork, Emma M.
    Aili, Daniel
    MATERIALS TODAY BIO, 2023, 19
  • [7] A review of monitoring technologies for real-time management of cyanobacteria: Recent advances and future direction
    Zamyadi, Arash
    Choo, Florence
    Newcombe, Gayle
    Stuetz, Richard
    Henderson, Rita K.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 85 : 83 - 96
  • [8] Recent Advances in Multiplexed Wearable Sensor Platforms for Real-Time Monitoring Lifetime Stress: A Review
    Kim, Heena
    Song, Jaeyoon
    Kim, Sehyeon
    Lee, Suyoung
    Park, Yejin
    Lee, Seungjun
    Lee, Seunghee
    Kim, Jinsik
    BIOSENSORS-BASEL, 2023, 13 (04):
  • [9] Recent Advances in Real-Time Maude
    Olveczky, Peter Csaba
    Meseguer, Jose
    ELECTRONIC NOTES IN THEORETICAL COMPUTER SCIENCE, 2007, 174 (01) : 65 - 81
  • [10] Smart wireless flexible bandage containing drug loaded polycaprolactone microparticles for real-time monitoring and treatment of chronic wounds
    Pazhouhnia, Zahra
    Farzin, Ali
    Rastgar, Hossein
    Dadgarnezhad, Manoochehr
    Jannat, Behrooz
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2024, 112 (08)