Emission characteristics of typical gas pollutants during oxygen-enriched waste incineration process

被引:1
|
作者
Liao, Wei [1 ]
Zhang, Xiong [1 ,3 ]
Fu, Zhe [1 ]
Zhang, Shihong [1 ]
Shao, Jingai [1 ,2 ]
Yang, Haiping [1 ]
Wang, Xianhua [1 ]
Chen, Hanping [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, State Key Lab Coal Combust, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Dept New Energy Sci & Engn, Wuhan 430074, Peoples R China
[3] 1037 Luoyu Rd, Wuhan 430074, Hubei, Peoples R China
关键词
Oxygen-enriched incineration; Municipal solid waste; Emission characteristic; Oxygen concentration; Moisture content; MUNICIPAL SOLID-WASTE; MSW; GASIFICATION; COMBUSTION; GENERATION; WOOD; COAL;
D O I
10.1016/j.eti.2023.103358
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Oxygen-enriched waste incineration can improve incineration efficiency and reduce pollutant generation, while greenhouse gases and pollutant emission characteristics of different wastes are still unclear. In this study, pollutant emission characteristics of actual municipal solid waste (MSW) and typical components at different oxygen concentrations and moisture content were investigated to reveal the pollutant generation mechanism. The results illustrated that when oxygen concentrations increased from 21% to 30%, CO, CH4 and HCN emissions decreased by 95%, 95.5% and 96.5%, respectively. NO emissions increased by 75% due to the promotion of oxygen on fuel NO and rapid NO. The slight increase in SO2 (from 25.8% to 26.87%) was due to the promotion of oxygen on organic S and the reaction between SO2-4 and HCl. The decrease in HCl emissions (from 78.42% to 76.85%) was caused by the increasing deacon reaction. Besides, with increasing moisture content, CO, CH4 and HCN generation decreased first because of the CO oxidation and CH4 reforming reaction, and then increased due to the water-gas reaction between fixed carbon and water. Furthermore, the moisture content contained (66%) would promote NO and HCl generation by 35.7% and 9.1% through fuel N oxidation by OH radicals and hydrolysis of chlorine salt at high temperatures. The increased oxygen concentration would inhibit the moisture influence and improve applicability for different MSW. In addition, 25% oxygen-enriched incineration was selected as the most suitable parameter for improving combustion efficiency and reducing pollutant emissions of MSW with high moisture content. (c) 2023 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Emission and Combustion Misfire of Engine with Oxygen-enriched in Dynamic Start Process
    Gao, Qing
    Liu, Chengcai
    Jin, Ying-Ai
    Zhang, Guangjun
    Ma, Chunqiang
    [J]. ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, : 117 - 120
  • [2] Prediction of Typical Flue Gas Pollutants from Municipal Solid Waste Incineration Plants
    Li, Shuya
    Zhang, Yifeng
    Song, Wenbin
    Zhang, Chunjiang
    Zhao, Chao
    Shen, Weiming
    Hai, Jing
    Lu, Jiawei
    Xie, Yingshi
    [J]. PROCEEDINGS OF THE 2021 IEEE 24TH INTERNATIONAL CONFERENCE ON COMPUTER SUPPORTED COOPERATIVE WORK IN DESIGN (CSCWD), 2021, : 1304 - 1309
  • [3] Study on Oxygen-Enriched Combustion Characteristics of Blast Furnace Gas Boiler
    Hu, Yuxuan
    Wang, Du
    Liao, Li
    Jin, Yafei
    Wang, Tingju
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 2024,
  • [4] BURNING OF NATURAL GAS WITH OXYGEN-ENRICHED AIR
    EFIMOV, LM
    [J]. STAL IN ENGLISH-USSR, 1969, (07): : 677 - &
  • [5] Oxygen-enriched air for co-incineration of organic sludges with municipal solid waste: A pilot plant experiment
    Chin, Sungmin
    Jurng, Jongsoo
    Lee, Jae-Heon
    Hur, Jin-Huek
    [J]. WASTE MANAGEMENT, 2008, 28 (12) : 2684 - 2689
  • [6] Emission characteristics of organic and heavy metal pollutants in fluidized bed incineration during the agglomeration/deluidization process
    Lin, CL
    Wey, MY
    Yu, WJ
    [J]. COMBUSTION AND FLAME, 2005, 143 (03) : 139 - 149
  • [7] Ignition and Flameout Characteristics of Micro Gas Turbine Oxygen-Enriched Combustion Chamber
    Wang, Fuzhen
    Wang, Neng
    Ren, Xiaochen
    Liu, Shi
    [J]. INTERNATIONAL CONFERENCE ON FRONTIERS OF ENVIRONMENT, ENERGY AND BIOSCIENCE (ICFEEB 2013), 2013, : 163 - 168
  • [8] An investigation of an oxygen-enriched combustion of municipal solid waste on flue gas emission and combustion performance at a 8 MWth waste-to-energy plant
    Ma, Chen
    Li, Bo
    Chen, Dongmei
    Weng, Terrence
    Ma, Wenchao
    Lin, Fawei
    Chen, Guanyi
    [J]. WASTE MANAGEMENT, 2019, 96 : 47 - 56
  • [9] The Characteristics of Oxygen-Enriched Gasification for Fluff SRF
    Gu, J. H.
    Park, Y. S.
    Nam, S. B.
    Yun, Y. S.
    Sung, H. J.
    Lee, J. K.
    Oh, J. H.
    Seo, Y. C.
    [J]. WASTE MANAGEMENT FOR RESOURCE UTILISATION, 2016, 35 : 541 - 545
  • [10] Safe for Oxygen but Not for Oxygen-Enriched Gas Mixtures in SCUBA Diving
    Tillack, T.
    Binder, C.
    Hesse, O.
    Lehne, S.
    Ciscato, W.
    [J]. FLAMMABILITY AND SENSITIVITY OF MATERIALS IN OXYGEN-ENRICHED ATMOSPHERES, VOL 13, 2012, 1561