Characteristics Analysis of Volatile Organic Compounds Pollution in Residential Buildings in Northeast China Based on Field Measurement

被引:2
|
作者
Sun, Wen [1 ]
Yan, Weidong [2 ]
Huang, Kailiang [1 ]
Song, Jiasen [3 ]
Liu, Guoqi [4 ]
机构
[1] Shenyang Jianzhu Univ, Sch Municipal & Environm Engn, Shenyang 110168, Peoples R China
[2] Shenyang Jianzhu Univ, Sch Civil Engn, Shenyang 110168, Peoples R China
[3] Chongqing Univ, Sch Civil Engn, Chongqing 400044, Peoples R China
[4] Shenyang Jianzhu Univ, Sch Comp Sci & Engn, Shenyang 110168, Peoples R China
基金
中国国家自然科学基金;
关键词
VOCs; field measurement; long-term online monitoring; ventilation modes; benzene carcinogenic risk; WINDOW-OPENING BEHAVIOR; THERMAL COMFORT; INDOOR; EXPOSURE; QUALITY; FORMALDEHYDE; TEMPERATURE; RISK; HOT;
D O I
10.3390/atmos14101543
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A total of 8 mechanically ventilated residential buildings and 8 naturally ventilated residential buildings were selected to analyze the pollution characteristics of indoor VOCs under different ventilation modes in the severe cold area of northeast China. On typical meteorological days in each season, VOCs were detected on site, and ventilation modes were investigated by long-term online monitoring. The test results showed that the TVOC (total volatile organic compounds) concentrations varied greatly in different seasons or different functional rooms, and the TVOC concentration was the highest in winter, with a value of 0.994 mg/m3. The kitchen was the place with the most serious VOC pollution, and the TVOC concentration could reach 1.403 mg/m3. Benzene series and methylsiloxane had the highest detection rates, but the detected concentrations were low, and the average concentrations were 0.025 mg/m3 and 0.013 mg/m3 respectively. Among the VOC types with a detection rate greater than 50%, the average proportions of aldehydes, alkanes, and benzene series were 18.7%, 15.39%, and 14.38%, respectively. And their mass ratios were also high, which were 14.90%, 30.85%, and 15.70%, respectively. The annual daily average ventilation duration of mechanically ventilated residential buildings was 7.84 h longer than that of naturally ventilated residential buildings. The median TVOC concentrations of mechanically ventilated residential buildings and naturally ventilated residential buildings were 0.621 mg/m3 and 0.707 mg/m3, respectively. The fresh air system was applicable in the severe cold area of northeast China.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Dynamics of indoor volatile organic compounds and seasonal ventilation strategies for residential buildings in Northeast China
    Yin, Tingting
    Gao, Weijun
    Wei, Xindong
    Wu, Lei
    Wang, Chao
    [J]. INDOOR AND BUILT ENVIRONMENT, 2024,
  • [2] Analysis of winter formaldehyde and volatile organic compound pollution characteristics of residential kitchens in severe cold regions of northeast China
    Wag, Jun
    Huang, Kailiang
    Feng, Guohui
    Song, Jiasen
    [J]. INDOOR AND BUILT ENVIRONMENT, 2021, 30 (08) : 1226 - 1243
  • [3] Pollution data analysis and characteristics of volatile organic compounds in the environment
    Wang, Qi
    Wang, Chen
    Hou, Lujian
    Lv, Bo
    Wang, Chen
    [J]. 2018 4TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING (ICEMEE 2018), 2018, 38
  • [4] Ambient volatile organic compounds pollution in China
    Zhang, Xinmin
    Xue, Zhigang
    Li, Hong
    Yan, Li
    Yang, Yuan
    Wang, Yi
    Duan, Jingchun
    Li, Lei
    Chai, Fahe
    Cheng, Miaomiao
    Zhang, Weiqi
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2017, 55 : 69 - 75
  • [5] Ambient volatile organic compounds pollution in China
    Xinmin Zhang
    Zhigang Xue
    Hong Li
    Li Yan
    Yuan Yang
    Yi Wang
    Jingchun Duan
    Lei Li
    Fahe Chai
    Miaomiao Cheng
    Weiqi Zhang
    [J]. Journal of Environmental Sciences, 2017, (05) - 75
  • [6] Ambient volatile organic compounds pollution in China
    Xinmin Zhang
    Zhigang Xue
    Hong Li
    Li Yan
    Yuan Yang
    Yi Wang
    Jingchun Duan
    Lei Li
    Fahe Chai
    Miaomiao Cheng
    Weiqi Zhang
    [J]. Journal of Environmental Sciences, 2017, 55 (05) : 69 - 75
  • [7] Indoor air quality analysis of residential buildings in northeast China based on field measurements and longtime monitoring
    Huang, Kailiang
    Song, Jiasen
    Feng, Guohui
    Chang, Qunpeng
    Jiang, Bian
    Wang, Jun
    Sun, Wen
    Li, Huixing
    Wang, Jinming
    Fang, Xianshi
    [J]. BUILDING AND ENVIRONMENT, 2018, 144 : 171 - 183
  • [8] Pollution characteristics of ambient volatile organic compounds (VOCs) in the southeast coastal cities of China
    Tong, Lei
    Liao, Xu
    Chen, Jinsheng
    Xiao, Hang
    Xu, Lingling
    Zhang, Fuwang
    Niu, Zhenchuan
    Yu, Jianshuan
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2013, 20 (04) : 2603 - 2615
  • [9] Pollution characteristics of ambient volatile organic compounds (VOCs) in the southeast coastal cities of China
    Lei Tong
    Xu Liao
    Jinsheng Chen
    Hang Xiao
    Lingling Xu
    Fuwang Zhang
    Zhenchuan Niu
    Jianshuan Yu
    [J]. Environmental Science and Pollution Research, 2013, 20 : 2603 - 2615
  • [10] Analysis of Characteristics of Volatile Organic Compounds Pollution in Atmosphere in Kuitun City and Countermeasures
    Wang, Linna
    Yang, Rongjiang
    Men, Chunyan
    Gao, Li
    [J]. 3RD INTERNATIONAL CONFERENCE ON AIR POLLUTION AND ENVIRONMENTAL ENGINEERING, 2020, 631