Development of a nucleic acid-based screen printed electrochemical biosensor using Ti3C2Tx-MXene for the detection of SARS-CoV-2

被引:8
|
作者
Bharti, Anu [1 ]
Singh, Sonam [1 ,2 ]
Munthala, Dhanunjaya [3 ]
Roy, Souradeep [1 ,4 ]
Pojprapai, Soodkhet [3 ]
Suksaweang, Sanong [5 ]
Sain, Sourav [6 ]
Roy, Susanta Sinha [6 ]
Mohamed, Julie Juliewatty [7 ]
Avasthi, Devesh Kumar [1 ]
Mathur, Ashish [1 ]
机构
[1] UPES, Ctr Interdisciplinary Res & Innovat CIDRI, Dehra Dun, India
[2] UPES, Sch Adv Engn, Dept Chem, Dehra Dun, India
[3] Suranaree Univ Technol, Sch Ceram Engn, Nakhon Ratchasima, Thailand
[4] UPES, Sch Hlth Sci & Technol, Dehra Dun, India
[5] Suranaree Univ Technol, Inst Med, Nakhon Ratchasima, Thailand
[6] Shiv Nadar Univ Inst Eminence, Sch Nat Sci, Dept Phys, Greater Noida, India
[7] Univ Malaysia Kelantan, Fac Bioengn & Technol, Dept Mat Technol, Kota Baharu, Malaysia
关键词
SARS-CoV-2; Nucleic Acid; COVID-19; Electrochemical Biosensor; Ti 3 C 2 T x -MXene; Screen Printed Carbon Electrode;
D O I
10.1016/j.microc.2023.109521
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The SARS-CoV-2 virus poses a major risk to human health which has put a tremendous strain on already stretched healthcare resources. Despite continuous improvements in Coronavirus Disease-19 (COVID-19) detection, treatment technology and ongoing global immunization efforts, the lethal virus has undergone several mutations and is still claiming millions of lives worldwide. In this respect, the development of a hybridization based nucleic acid biosensor for SARS-CoV-2 virus is the major focus of the current effort in response to the critical demand for developing quick and accurate diagnostic methods. Herein, we employ Screen Printed Carbon Electrode (SPCE) coated with Ti3C2Tx-MXene nanosheets followed by amino-functionalized probe DNA (NH2- pDNA) as a robust surface for the sensing of SARS-CoV-2. Electrochemical impedance spectroscopy, cyclic voltammetry and differential pulse voltammetry were employed for assessing the electrochemical behavior of NH2- pDNA/Ti3C2Tx/SPCE bioelectrode. Meanwhile, the analytical sensor response for SARS-CoV-2 was studied using impedance within target DNA concentration of 0.1 pM 1 mu M. The developed biosensor displayed detection limit of 0.004 pM, showing a high degree of selectivity in the presence of non-complementary interferents with a shelf life of 40 days. Additionally, a good linearity for the detection of target sequence in spiked serum samples was established; as a result, exhibiting huge potential for use in the contemporary healthcare sector for fast, accurate and reliable diagnosis of COVID-19 in a point-of-care scenario.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Nucleic Acid-Based Diagnostic Tests for the Detection SARS-CoV-2: An Update
    Yu, Choo Yee
    Chan, Kok Gan
    Yean, Chan Yean
    Ang, Geik Yong
    DIAGNOSTICS, 2021, 11 (01)
  • [2] Ni Nanoparticles Embedded Ti3C2Tx-MXene Nanoarchitectures for Electrochemical Sensing of Methylmalonic Acid
    Kumar, Jai
    Soomro, Razium Ali
    Neiber, Rana R.
    Ahmed, Nazeer
    Medany, Shymaa S.
    Albaqami, Munirah D.
    Nafady, Ayman
    BIOSENSORS-BASEL, 2022, 12 (04):
  • [3] Functionalized Ti3C2Tx Nanosheets Based Biosensor for Point-of-Care Detection of SARS-CoV-2 Antigen
    Singh, Chandan
    Hoefs, Soraya
    Konthur, Zoltan
    Hodoroaba, Vasile-Dan
    Radnik, Joerg
    Schenk, Joerg A.
    Schneider, Rudolf J.
    ACS APPLIED ENGINEERING MATERIALS, 2023, 1 (01): : 495 - 507
  • [4] Rapid, multiplexed, and nucleic acid amplification-free detection of SARS-CoV-2 RNA using an electrochemical biosensor
    Kashefi-Kheyrabadi, Leila
    Nguyen, Huynh Vu
    Go, Anna
    Baek, Changyoon
    Jang, Nayoon
    Lee, Jiwon Michelle
    Cho, Nam-Hyuk
    Min, Junhong
    Lee, Min-Ho
    BIOSENSORS & BIOELECTRONICS, 2022, 195
  • [5] Self-assembled Ti3C2Tx-MXene/PTh composite electrodes for electrochemical capacitors
    Juanqin Xue
    Yuzhu Shi
    Wenqiao Wang
    Yongqi Yu
    Changbin Tang
    Journal of Materials Science: Materials in Electronics, 2022, 33 : 6636 - 6645
  • [6] Self-assembled Ti3C2Tx-MXene/PTh composite electrodes for electrochemical capacitors
    Xue, Juanqin
    Shi, Yuzhu
    Wang, Wenqiao
    Yu, Yongqi
    Tang, Changbin
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2022, 33 (09) : 6636 - 6645
  • [7] Development of nucleic acid based lateral flow assays for SARS-CoV-2 detection
    Derin, Dilek Cam
    Gultekin, Enes
    Taskin, Irmak Icen
    Yakupogullari, Yusuf
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2023, 135 (02) : 87 - 92
  • [8] Electrochemical ultrasensitive detection of CYFRA21-1 using Ti3C2Tx-MXene as enhancer and covalent organic frameworks as labels
    Cheng, Jiamin
    Hu, Kai
    Liu, Qianrui
    Liu, Yanju
    Yang, Huaixia
    Kong, Jinming
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) : 2543 - 2551
  • [9] Electrochemical ultrasensitive detection of CYFRA21-1 using Ti3C2Tx-MXene as enhancer and covalent organic frameworks as labels
    Jiamin Cheng
    Kai Hu
    Qianrui Liu
    Yanju Liu
    Huaixia Yang
    Jinming Kong
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2543 - 2551
  • [10] A review of electrochemical biosensor application in the detection of the SARS-COV-2
    Jiang, Chunying
    Mu, Xihui
    Du, Bin
    Tong, Zhaoyang
    MICRO & NANO LETTERS, 2022, 17 (03) : 49 - 58