Large depth of field and high-resolution optical coherence tomography angiography with a needle-shaped beam

被引:0
|
作者
Guo, Xiangyu [1 ]
Zhao, Jingjing [2 ]
de la Zerda, Adam [2 ]
Sun, Liqun [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, Beijing 100084, Peoples R China
[2] Stanford Univ, Dept Struct Biol, Stanford, CA 94305 USA
来源
OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XIII | 2023年 / 12770卷
关键词
optical coherence tomography angiography; diffractive optical elements; needle-shaped beam; brain imaging;
D O I
10.1117/12.2686500
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography angiography (OCTA) has emerged as a highly competitive technique for visualizing blood perfusion without the need for exogenous contrast agents. However, for high-resolution optical imaging, the pursuit of diffraction-limited resolution is often accompanied by a trade- off in the form of a reduced depth of field (DOF). This constraint impedes the rapid acquisition of high-resolution images of samples with irregular surfaces. Achieving these goals usually involves laborious axial scanning at multiple planes and complicated image processing procedures, or using non-diffracting beams such as Bessel or Airy beams to simultaneously achieve large DOF and high resolution, but the imaging quality is usually limited by the severe sidelobes and low efficiency of the beams. To solve this problem, we developed a needle-shaped beam (NB) through a spatially multiplexed phase pattern that creates many axially closely spaced foci. The phase mask was created on a diffractive optical element (DOE) which was fabricated on a 500-mu m- thick fused silica substrate via four rounds of lithography. The DOE was introduced into the OCTA system and converted the conventional Gaussian beam (GB) OCTA system into the NB-OCTA system, which has both long DOF and high resolution, maintaining 8 mu m lateral resolution over a depth range of 620 mu m, allowing real-time, nonstitched, large-field (6.4x4 mm) imaging of samples with uneven surfaces. Imaging of mouse brains with natural curvature was demonstrated in our work, compared to GB-OCTA, NB-OCTA captures the high- resolution distribution of blood vessels within a larger depth range.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Visualizing cortical blood perfusion after photothrombotic stroke in vivo by needle-shaped beam optical coherence tomography angiography
    Guo, Xiangyu
    Zhao, Jingjing
    Sun, Liqun
    Gupta, Varun
    Du, Lin
    Sharma, Komal
    Van Vleck, Aidan
    Liang, Kaitlyn
    Cao, Liangcai
    Kong, Lingjie
    Yang, Yuanmu
    Huang, Yong
    de la Zerda, Adam
    Jin, Guofan
    PHOTONIX, 2024, 5 (01)
  • [2] Visualizing cortical blood perfusion after photothrombotic stroke in vivo by needle-shaped beam optical coherence tomography angiography
    Xiangyu Guo
    Jingjing Zhao
    Liqun Sun
    Varun Gupta
    Lin Du
    Komal Sharma
    Aidan Van Vleck
    Kaitlyn Liang
    Liangcai Cao
    Lingjie Kong
    Yuanmu Yang
    Yong Huang
    Adam de la Zerda
    Guofan Jin
    PhotoniX, 5
  • [3] Optical-resolution photoacoustic microscopy with a needle-shaped beam
    Rui Cao
    Jingjing Zhao
    Lei Li
    Lin Du
    Yide Zhang
    Yilin Luo
    Laiming Jiang
    Samuel Davis
    Qifa Zhou
    Adam de la Zerda
    Lihong V. Wang
    Nature Photonics, 2023, 17 : 89 - 95
  • [4] Optical-resolution photoacoustic microscopy with a needle-shaped beam
    Cao, Rui
    Zhao, Jingjing
    Li, Lei
    Du, Lin
    Zhang, Yide
    Luo, Yilin
    Jiang, Laiming
    Davis, Samuel
    Zhou, Qifa
    de la Zerda, Adam
    Wang, Lihong, V
    NATURE PHOTONICS, 2023, 17 (01) : 89 - +
  • [5] High-resolution optical coherence tomography over a large depth range with an axicon lens
    Ding, ZH
    Ren, HW
    Zhao, YH
    Nelson, JS
    Chen, ZP
    OPTICS LETTERS, 2002, 27 (04) : 243 - 245
  • [6] Long-term in vivo visualization of cortical blood perfusion after photothrombotic stroke with needle-shaped beam optical coherence tomography angiography
    Guo, Xiangyu
    Zhao, Jingjing
    De la Zerda, Adam
    Sun, Liqun
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXVIII, 2024, 12830
  • [7] Generation of needle-shaped beam with super-resolution spot and large depth of focus using diffractive optics
    Du, Yuzhe
    Zhang, Cilong
    Tan, Qiaofeng
    OPTICS COMMUNICATIONS, 2024, 563
  • [8] Flexible method for generating needle-shaped beams and its application in optical coherence tomography
    Zhao, Jingjing
    Winetraub, Yonatan
    Du, Lin
    Van Vleck, Aidan
    Ichimura, Kenzo
    Huang, Cheng
    Aasi, Sumaira Z.
    Sarin, Kavita Y.
    de la Zerda, Adam
    OPTICA, 2022, 9 (08): : 859 - 867
  • [9] High-Resolution Patterned Transfer Using Needle-Shaped Ferrite Nanocrystals
    Ingert, D.
    Pileni, M. P.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2008, 112 (49): : 19329 - 19335
  • [10] High-resolution polarization-sensitive optical coherence tomography and optical coherence tomography angiography for zebrafish skin imaging
    Yang, Di
    Yuan, Zhuoqun
    Yang, Zihan
    Hu, Muyun
    Liang, Yanmei
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2021, 14 (06)