Accuracy of Self-Injection Locking Radar System for Vital Signs Detection During the COVID-19 Pandemic at a Hospital in Taiwan: Measuring Vital Signs Accurately with SIL Radar for Hospital Healthcare

被引:0
|
作者
Tzou, Shiow-Jyu [1 ,2 ]
Chen, I-Hung [2 ,3 ]
Chu, Tian-Huei [1 ,2 ]
Chian, De-Ming [4 ]
Wang, Fu-Kang [5 ]
Lee, Yung-Kuo [1 ,2 ]
Ko, Chou-Yuan [2 ,6 ]
机构
[1] Kaohsiung Armed Forces Gen Hosp, Med Educ & Res Ctr, Med Lab, Kaohsiung, Taiwan
[2] Natl Sun Yat Sen Univ, Dept Elect Engn, Kaohsiung, Taiwan
[3] Natl Sun Yat Sen Univ, Inst Commun Engn, Kaohsiung, Taiwan
[4] Kaohsiung Armed Forces Gen Hosp, Div Gastroenterol & Hepatol, Dept Internal Med, Kaohsiung, Taiwan
[5] Kaohsiung Armed Forces Gen Hosp, Pingtung Branch, Div Nephrol, Pingtung, Taiwan
[6] Natl Sun Yat Sen Univ, Inst Med Sci & Technol, Kaohsiung, Taiwan
来源
MEDICAL SCIENCE MONITOR | 2023年 / 29卷
关键词
Data Accuracy; Heart Rate; Radar; Respiratory Rate; Vital Signs; AGREEMENT; TRACKING;
D O I
10.12659/MSM.939949
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Self-injection locking (SIL) radar uses continuous-wave radar and an injection-locked oscillator-based frequen-cy discriminator that receives and demodulates radar signals remotely to monitor vital signs. This study aimed to compare SIL radar with traditional electrocardiogram (ECG) measurements to monitor respiratory rate (RR) and heartbeat rate (HR) during the COVID-19 pandemic at a single hospital in Taiwan. Material/Methods: We recruited 31 hospital staff members (16 males and 15 females) for respiratory rates (RR) and heartbeat rates (HR) detection. Data acquisition with the SIL radar and traditional ECG was performed simultaneously, and the accuracy of the measurements was evaluated using Bland-Altman analysis. Results: To analyze the results, participates were divided into 2 groups (individual subject and multiple subjects) by gen-der (male and female), or 4 groups (underweight, normal weight, overweight, and obesity) by body mass index (BMI). The results were analyzed using mean bias errors (MBE) and limits of agreement (LOA) with a 95% con-fidence interval. Bland-Altman plots were utilized to illustrate the difference between the SIL radar and ECG monitor. In all BMI groups, results of RR were more accurate than HR, with a smaller MBE. Furthermore, RR and HR measurements of the male groups were more accurate than those of the female groups. Conclusions: We demonstrated that non-contact SIL radar could be used to accurately measure HR and RR for hospital health-care during the COVID-19 pandemic.
引用
收藏
页数:9
相关论文
共 12 条
  • [1] Cost-effective vital signs monitoring system for COVID-19 patients in smart hospital
    Raghied M. Atta
    Health and Technology, 2022, 12 : 239 - 253
  • [2] Cost-effective vital signs monitoring system for COVID-19 patients in smart hospital
    Atta, Raghied M.
    HEALTH AND TECHNOLOGY, 2022, 12 (01) : 239 - 253
  • [3] A Real-Time Wearable System for Monitoring Vital Signs of COVID-19 Patients in a Hospital Setting
    Santos, Mauro D.
    Roman, Cristian
    Pimentel, Marco A. F.
    Vollam, Sarah
    Areia, Carlos
    Young, Louise
    Watkinson, Peter
    Tarassenko, Lionel
    FRONTIERS IN DIGITAL HEALTH, 2021, 3
  • [4] Vital signs assessed in initial clinical encounters predict COVID-19 mortality in an NYC hospital system
    Elza Rechtman
    Paul Curtin
    Esmeralda Navarro
    Sharon Nirenberg
    Megan K. Horton
    Scientific Reports, 10
  • [5] Vital signs assessed in initial clinical encounters predict COVID-19 mortality in an NYC hospital system
    Rechtman, Elza
    Curtin, Paul
    Navarro, Esmeralda
    Nirenberg, Sharon
    Horton, Megan K.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [6] Effects of the use of face masks on the vital signs and headache of healthy healthcare workers during the COVID-19 pandemic: A hospital-based cross-sectional study
    Hoseinzadeh, Edris
    Mohammadi, Farshid
    Razaghi, Mahta
    Mansuri, Ramin
    Alipour, Sara
    Safari, Mahdi
    Allen, Sokan-Adeaga Adewale
    JOURNAL OF HAZARDOUS MATERIALS ADVANCES, 2024, 14
  • [7] Effects of the Use of N95 Masks on the Vital Signs of Healthy Healthcare Workers During the COVID-19 Pandemic: A Hospital-Based Cross-Sectional Study
    Kumar, Pradeep
    Nath, Kunal
    Prasad, Arun
    Tiwari, Lokesh K.
    Chowdhry, Bhabesh K.
    Sinha, Amit K.
    Chaudhary, Neha
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (06)
  • [8] Detection of Concealed Individuals Based on Their Vital Signs by Using a See-Through-Wall Imaging System With a Self-Injection-Locked Radar
    Wang, Fu-Kang
    Horng, Tzyy-Sheng
    Peng, Kang-Chun
    Jau, Je-Kuan
    Li, Jian-Yu
    Chen, Cheng-Chung
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (01) : 696 - 704
  • [9] Time-Division Multiplexing MIMO Radar System With Self-Injection-Locking for Image Hotspot-Based Monitoring of Multiple Human Vital Signs
    Su, Wei-Chih
    Lai, Yi-Chen
    Horng, Tzyy-Sheng
    El Arif, Rezki
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2024, 72 (03) : 1943 - 1952
  • [10] Signs of front-line healthcare professionals' information anxiety during the COVID-19 pandemic: Grounded theory study in a Wuhan hospital
    Lu, Quan
    Tao, Liang
    Peng, Xueying
    Chen, Jing
    NURSING OPEN, 2024, 11 (06):