Multilayer coating-assisted gold-encapsulated tilted fiber Bragg grating biosensor design

被引:3
|
作者
Prathap, P. B. [1 ,2 ]
Saara, K. [1 ]
机构
[1] Dayananda Sagar Univ, Sch Engn, Dept Elect & Commun Engn, Bangalore 560114, India
[2] Malnad Coll Engn, Dept Elect & Commun Engn, Hassan 573202, India
来源
关键词
Fiber Bragg grating; Biosensor; Multilayer encapsulation; Surface plasmon resonance; Protein analysis; Immunological analysis; RESONANCES; SENSORS;
D O I
10.1007/s12596-024-01711-6
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To cope with up high rise in healthcare demands and accurate clinical decisions the fiber Bragg grating (FBG) sensors have performed superior over the traditional analog sensors for varied clinical decisions. The higher sensitivity and resolution toward accurate sensing make FBG a viable technology for clinical decision systems including biomechanical sensing, physiological sensing, non-invasive surgery, and biosensing. Depth assessment indicates that the encapsulated tilted FBG (TFBG), and surface plasmon resonance sensors have performed satisfactorily; yet, their suitability over the different operating conditions such as temperature, viscosity-change, noise, etc., remains suspicious. The at-hand biosensors fail to demodulate the response accurately once the surrounding refractive index approaches the cladding index. It requires a sufficiently large spectrum shift to demodulate and predict biosensing yield. To achieve it, in this paper, a multilayer coating-assisted gold-encapsulated TFBG biosensor is proposed. The proposed TFBG biosensor was designed with the grating angle of 10 circle\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$10<^>{ \circ }$$\end{document}, while gold encapsulation was done to improve resolution and sensitivity. To improve biosensing toward protein analysis and immunological assessment at first gold plating was done to improve reflectivity, while graphene oxide (GO) coating was done to enhance plasmonic attraction for biosensing. In function, GO coating served dual purposes including improved antibody and antigen absorption that helped sensitivity as well as yields sufficiently large spectra change to make detection decisions. More specifically, GO coating enables the trapping of the target molecules that eventually increases the refractive index of the coating material and hence undergoes a shift in the wavelength spectra, which is used for biosensing tasks. The higher refractive index of the coating material over the cladding index results in spectral shift and coupling wavelength shifts which helps target biosensing tasks. Simulations confirmed wavelength spectrum shift signifying biosensing tasks including protein analysis and immunological assessments for clinical decisions.
引用
收藏
页数:10
相关论文
共 35 条
  • [1] Self-compensating gold-encapsulated tilted fiber Bragg grating for peak tracking based biosensing applications
    Prathap, P. B.
    Saara, K.
    JOURNAL OF OPTICS-INDIA, 2023, 53 (3): : 2005 - 2019
  • [2] Self-compensating gold-encapsulated tilted fiber Bragg grating for peak tracking based biosensing applications
    Prathap, P. B.
    Saara, K.
    JOURNAL OF OPTICS-INDIA, 2024, 53 (03): : 2005 - 2019
  • [3] DNA Biosensor Based On A Double Tilted Fiber Bragg Grating
    Candiani, Alessandro
    Sozzi, Michele
    Cucinotta, Annamaria
    Veneziano, Rosanna
    Corradini, Roberto
    Childs, Paul
    Pissadakis, Stavros
    Selleri, Stefano
    2012 IEEE PHOTONICS CONFERENCE (IPC), 2012, : 206 - +
  • [4] Gold nanosell immobilized excessively tilted fiber grating biosensor
    Lu, Huafeng
    Lu, Jiao
    Luo, Binbin
    Shi, Shenghui
    Zhao, Mingfu
    2018 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2018,
  • [5] A Poly(vinyl alcohol) Coating Method for a Tilted-Fiber Bragg-Grating-Assisted Fiber Hygrometer
    Dolzhenko, Egor I.
    Tomyshev, Kirill
    Butov, Oleg V.
    PHYSICA STATUS SOLIDI-RAPID RESEARCH LETTERS, 2020, 14 (12):
  • [6] Tilted Fiber Bragg Grating Sensor with Graphene Oxide Coating for Humidity Sensing
    Chiu, Yung-Da
    Wu, Chao-Wei
    Chiang, Chia-Chin
    SENSORS, 2017, 17 (09):
  • [7] Label-free DNA biosensor based on doubled tilted fiber Bragg grating
    Candiani, Alessandro
    Sozzi, Michele
    Cucinotta, Annamaria
    Selleri, Stefano
    Veneziano, Rosanna
    Corradini, Roberto
    Marchelli, Rosangela
    Childs, Paul
    Pissadakis, Stavros
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XII, 2012, 8218
  • [8] Tilted fiber Bragg grating design for a simultaneous measurement of temperature and strain
    Kipriksiz, Selin Ece
    Yucel, Murat
    OPTICAL AND QUANTUM ELECTRONICS, 2021, 53 (01)
  • [9] Tilted fiber Bragg grating design for a simultaneous measurement of temperature and strain
    Selin Ece Kipriksiz
    Murat Yücel
    Optical and Quantum Electronics, 2021, 53
  • [10] Weak feedback assisted random fiber laser from 45°-tilted fiber Bragg grating
    Hu, Zhijia
    Ma, Rui
    Zhang, Xiaojuan
    Sun, Zhongyuan
    Liu, Xin
    Liu, Jun
    Xie, Kang
    Zhang, Lin
    OPTICS EXPRESS, 2019, 27 (03) : 3255 - 3263