Understanding and eliminating the reductant interference on Chromium VI measurement with USEPA method 3060A

被引:3
|
作者
Yu, Huilin [1 ,2 ,3 ]
Zhu, Hongtao [1 ,2 ,5 ]
Zhang, Danfeng [4 ]
Wang, Xingrun [3 ]
机构
[1] Beijing Forestry Univ, Beijing Key Lab Source Control Technol Water Pollu, Beijing 100083, Peoples R China
[2] Beijing Forestry Univ, Coll Environm Sci & Engn, Engn Res Ctr Water Pollut Source Control & Ecoreme, Beijing 100083, Peoples R China
[3] Chinese Res Inst Environm Sci, State Key Lab Environm Criteria & Risk Assessment, Beijing 100012, Peoples R China
[4] Sichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610066, Peoples R China
[5] Beijing Forestry Univ, Beijing Key Lab Source Control Technol Water Pollu, Beijing 100083, Peoples R China
关键词
COPR; USEPA method 3060A; Interference; FeSO4; CaS5; Cr(VI); ORE PROCESSING RESIDUE; CALCIUM POLYSULFIDE; HEXAVALENT CHROMIUM; CONTAMINATED SOIL; FERROUS SULFATE; SODIUM SULFIDE; CR(VI); REMEDIATION; IRON; COPR;
D O I
10.1016/j.scitotenv.2023.163192
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Excessive reductants are used in engineering to ensure a reliable remediation effect of chromite ore processing residue (COPR), however, re-yellowing phenomenon of remediated COPR occurs after some time though the Cr(VI) content meets regulatory requirements after curing period. This problem is due to a negative bias on Cr(VI) determination using USEPA method 3060A. To address this issue, this study tried to reveal the interference mechanisms and proposed two methods to amend the bias. Results of ion concentrations, UV-Vis spectrum, XRD, and XPS together showed that Cr(VI) was reduced by ions (Fe2+, S52-) in the digestion stage of USEPA method 3060A, and as a result, method 7196A would not reflect the true Cr(VI) concentration. The interference on Cr(VI) determination generated by excess reduc-tants mainly occurs during the curing period of remediated COPR, but it decreases over time as reductants being oxi-dized gradually by the air. Compared with the thermal oxidation, the chemical oxidation with K2S2O8 prior to alkaline digestion performs better to eliminate the masking effect brought by excess reductants. This study provides an ap-proach on how to accurately determine the Cr(VI) concentration in the remediated COPR. It might be helpful to reduce the occurrence possibility of re-yellowing phenomenon.
引用
收藏
页数:10
相关论文
共 13 条
  • [1] Toluene-mercuric modified USEPA Method 3060A to eliminate interference of sulfide-based reductants with Cr(VI) determination
    Pang, Jingli
    Luo, Yating
    Yang, Yuanqiang
    Tong, Jianhao
    Wang, Lubin
    Wu, Hanxin
    Shi, Jiyan
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 887
  • [2] Interference of sulfide with iron ions to the analysis of Cr(VI) by Method 3060a & Method 7196a
    Hu, Siyang
    Li, Dong
    Qin, Shiqiang
    Man, Yidong
    Huang, Chuan
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2020, 398
  • [3] Evaluation of Hexavalent Chromium Extraction Method EPA Method 3060A for Soils Using XANES Spectroscopy
    Malherbe, Julien
    Isaure, Marie-Pierre
    Seby, Fabienne
    Watson, Russell P.
    Rodriguez-Gonzalez, Pablo
    Stutzman, Paul E.
    Davis, Clay W.
    Maurizio, Chiara
    Unceta, Nora
    Sieber, John R.
    Long, Stephen E.
    Donard, Olivier F. X.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (24) : 10492 - 10500
  • [4] Modifications to EPA Method 3060A to Improve Extraction of Cr(VI) from Chromium Ore Processing Residue-Contaminated Soils
    Mills, Christopher T.
    Bern, Carleton R.
    Wolf, Ruth E.
    Foster, Andrea L.
    Morrison, Jean M.
    Benzel, William M.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (19) : 11235 - 11243
  • [5] A BETTER METHOD FOR ELIMINATING SALICYLATE INTERFERENCE WITH MEASUREMENT OF ACETAMINOPHEN
    LIU, TZ
    BIGLER, WN
    [J]. CLINICAL CHEMISTRY, 1983, 29 (03) : 590 - 590
  • [6] Development of an ion chromatographic Measurement Method for Chromium (VI)
    Buetow, C.
    Monz, C.
    Timm, K.
    [J]. GEFAHRSTOFFE REINHALTUNG DER LUFT, 2019, 79 (04): : 109 - 113
  • [7] HYDROGEN-PEROXIDE INTERFERENCE IN THE DETERMINATION OF CHROMIUM(VI) BY THE DIPHENYLCARBAZIDE METHOD
    PETTINE, M
    LANOCE, T
    LIBERATORI, A
    LORETI, L
    [J]. ANALYTICA CHIMICA ACTA, 1988, 209 (1-2) : 315 - 319
  • [8] A Method of Eliminating Adjacent Frequency Interference in Magnetic Field Measurement of Double Probe Fluxgate Magnetometer
    Tian Z.
    Zhang A.
    Zhou B.
    Ma L.
    Guan Y.
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 : 321 - 326and340
  • [9] THE DEVELOPMENT OF A METHOD FOR THE SIMULTANEOUS MEASUREMENT OF CERIUM (IV) AND CHROMIUM (VI) SPECIES IN NITRIC ACID MEDIA
    Nickson, Ian D.
    Boxall, Colin
    Jackson, Angela
    Whillock, Guy O. H.
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL REMEDIATION AND RADIOACTIVE WASTE MANAGEMENT 2009, VOL 1, 2010, : 163 - 169
  • [10] A method of eliminating the water vapor interference simultaneously in open path FTIR measurement by instrumental line shape correction
    Xu Liang
    Liu Jian-Guo
    Gao Min-Guang
    Lu Yi-Huai
    Liu Wen-Qing
    Wei Xiu-Li
    Zhang Tian-Shu
    Chen Hua
    Liu Zhi-Ming
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (05) : 1052 - 1056