Application of Texture and Volume Model Analysis to Dedicated Axillary High-resolution 3D T2-weighted MR Imaging: A Novel Method for Diagnosing Lymph Node Metastasis in Patients with Clinically Node-negative Breast Cancer

被引:1
|
作者
Shimizu, Hiroaki [1 ,2 ]
Mori, Naoko [1 ]
Mugikura, Shunji [1 ,3 ]
Maekawa, Yui [1 ]
Miyashita, Minoru [4 ]
Nagasaka, Tatsuo [5 ]
Sato, Satoko [6 ]
Takase, Kei [1 ]
机构
[1] Tohoku Univ, Dept Diagnost Radiol, Grad Sch Med, Sendai, Miyagi, Japan
[2] Tohoku Univ, Sch Med, Sendai, Miyagi, Japan
[3] Tohoku Univ, Tohoku Med Megabank Org, Div Image Stat, Sendai, Miyagi, Japan
[4] Tohoku Univ, Dept Surg Oncol, Grad Sch Med, Sendai, Miyagi, Japan
[5] Tohoku Univ, Dept Radiol Technol, Grad Sch Med, Sendai, Miyagi, Japan
[6] Tohoku Univ, Dept Anat Pathol, Grad Sch Med, Sendai, Miyagi, Japan
基金
日本学术振兴会;
关键词
breast neoplasms; lymph nodes; lymphatic metastasis; magnetic resonance imaging; metastasis; PERFORMANCE; SURVIVAL; WOMEN;
D O I
10.2463/mrms.mp.2022-0091
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effectiveness of the texture analysis of axillary high-resolution 3D T2-weighted imaging (T2WI) in distinguishing positive and negative lymph node (LN) metastasis in patients with clinically node-negative breast cancer. Methods: Between December 2017 and May 2021, 242 consecutive patients underwent high-resolution 3D T2WI and were classified into the training (n = 160) and validation cohorts (n = 82). We performed manual 3D segmentation of all visible LNs in axillary level I to extract the texture features. As the additional parameters, the number of the LNs and the total volume of all LNs for each case were calculated. The least absolute shrinkage and selection operator algorithm and Random Forest were used to construct the models. We constructed the texture model using the features from the LN with the largest least axis length in the training cohort. Furthermore, we constructed the 3 models combining the selected texture features of the LN with the largest least axis length, the number of LNs, and the total volume of all LNs: texture-number model, texture-volume model, and texture-number-volume model. As a conventional method, we manually measured the largest cortical diameter. Moreover, we performed the receiver operating curve analysis in the validation cohort and compared area under the curves (AUCs) of the models. Results: The AUCs of the texture model, texture-number model, texture-volume model, texture-number-volume model, and conventional method in the validation cohort were 0.7677, 0.7403, 0.8129, 0.7448, and 0.6851, respectively. The AUC of the texture-volume model was higher than those of other models and conventional method. The sensitivity, specificity, positive predictive value, and negative predictive value of the texture-volume model were 90%, 69%, 49%, and 96%, respectively. Conclusion: The texture-volume model of high-resolution 3D T2WI effectively distinguished positive and negative LN metastasis for patients with clinically node-negative breast cancer.
引用
收藏
页码:161 / 170
页数:10
相关论文
共 7 条
  • [1] Preoperative MR radiomics based on high-resolution T2-weighted images and amide proton transfer-weighted imaging for predicting lymph node metastasis in rectal adenocarcinoma
    Qiurong Wei
    Wenjing Yuan
    Ziqi Jia
    Jialiang Chen
    Ling Li
    Zhaoxian Yan
    Yuting Liao
    Liting Mao
    Shaowei Hu
    Xian Liu
    Weicui Chen
    Abdominal Radiology, 2023, 48 : 458 - 470
  • [2] Preoperative MR radiomics based on high-resolution T2-weighted images and amide proton transfer-weighted imaging for predicting lymph node metastasis in rectal adenocarcinoma
    Wei, Qiurong
    Yuan, Wenjing
    Jia, Ziqi
    Chen, Jialiang
    Li, Ling
    Yan, Zhaoxian
    Liao, Yuting
    Mao, Liting
    Hu, Shaowei
    Liu, Xian
    Chen, Weicui
    ABDOMINAL RADIOLOGY, 2023, 48 (02) : 458 - 470
  • [3] Value of Breast MRI and Nomogram After Negative Axillary Ultrasound for Predicting Axillary Lymph Node Metastasis in Patients With Clinically T1-2 N0 Breast Cancer
    Song, Sung Eun
    Cho, Kyu Ran
    Cho, Yongwon
    Jung, Seung Pil
    Park, Kyong-Hwa
    Woo, Ok Hee
    Seo, Bo Kyoung
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2023, 38 (34)
  • [4] Application of Texture Analysis Based on Sagittal Fat-Suppression and Oblique Axial T2-Weighted Magnetic Resonance Imaging to Identify Lymph Node Invasion Status of Rectal Cancer
    Song, Lirong
    Yin, Jiandong
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [5] Inner ear volumetric measurements using high-resolution 3D T2-weighted fast spin-echo MR imaging: Initial experience in healthy subjects
    Melhem, ER
    Shakir, H
    Bakthavachalam, S
    MacDonald, CB
    Gira, J
    Caruthers, SD
    Jara, H
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (10) : 1819 - 1822
  • [6] High-resolution T2-weighted MR imaging of the inner ear using a long echo-train-length 3D east spin-echo sequence
    Naganawa, S
    Yamakawa, K
    Fukatsu, H
    Ishigaki, T
    Nakashima, T
    Sugimoto, H
    Aoki, I
    Miyazaki, M
    Takai, H
    EUROPEAN RADIOLOGY, 1996, 6 (03) : 369 - 374
  • [7] A NOVEL 3D HIGH-RESOLUTION HISTOPATHOLOGICAL IMAGE RECONSTRUCTION METHOD VERSUS COMMON 2D AND 3D IMAGING METHODOLOGIES FOR APPLICATION IN CANCER SPHEROID RESEARCH: WHICH IS BETTER?
    Samarasekara, James
    Esteves, Filomena
    Curd, Alistair
    Hale, Michael
    Magee, Derek
    Treanor, Darren
    Short, Susan
    Bruning-Richardson, Anke
    NEURO-ONCOLOGY, 2018, 20 : 271 - 271