Eye lens dose in spine surgeons during myelography procedures: a dosimetry study

被引:0
|
作者
Nagamoto, Keisuke [1 ]
Kawachino, Tomonori [1 ]
Suetsugu, Yoshiki [1 ]
Saruwatari, Hiromi [1 ]
Nihei, Shun-ichi [2 ]
Kunugita, Naoki [3 ]
机构
[1] Hosp Univ Occupat & Environm Hlth, Dept Radiol, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Emergency & Intens Care Med, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[3] Univ Occupat & Environm Hlth, Dept Occupat & Community Hlth, Nursing Sch Hlth Sci, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
关键词
3 mm dose equivalent; Hp(3); lens dose; myelography; spine surgeons; radio-photoluminescence glass dosimeters; x-ray tube system; INTERVENTIONAL RADIOLOGY; RADIATION-EXPOSURE; FLUOROSCOPY; TRIAL; CT;
D O I
10.1088/1361-6498/ad0b3a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the eye lens dose (3 mm dose equivalent [Hp(3)]) received by spine surgeons during myelography and evaluate the effectiveness of radiation-protective glasses and x-ray tube system positioning in reducing radiation exposure. This study included spine surgeons who performed myelography using over- or under-table x-ray tube systems. Hp(3) was measured for each examination using a radio-photoluminescence glass dosimeter (GD-352M) mounted on radiation-protective glass. This study identified significantly high Hp(3) levels, especially in the right eye lens in spinal surgeons. The median Hp(3) values in the right eye were 524 (391-719) and 58 (42-83) mu Sv/examination for over- and under-table x-ray tube systems, respectively. Further, Hp(3)AK, which was obtained by dividing the cumulative air kerma from Hp(3), was 8.09 (6.69-10.21) and 5.11 (4.06-6.31) mu Sv mGy-1 for the over- and under-table x-ray tube systems, respectively. Implementing radiation-protective glasses resulted in dose reduction rates of 54% (50%-57%) and 54% (51%-60%) for the over- and under-table x-ray tube systems, respectively. The use of radiation protection glasses significantly reduced the radiation dose in the eye lens during myelography, with the most effective measures being the combination of using radiation protection glasses and an under-table x-ray tube system.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Hp(3) vs TLD-100 for eye lens dosimetry in interventional radiology procedures: a preliminary study
    Manna, Francesco
    De Nardellis, Gianleonardo
    Carmosino, Patrizio Antonio
    Ambrosino, Fabrizio
    Caruso, Umberto
    Correra, Marco
    Fiore, Francesco
    La Verde, Giuseppe
    Tarotto, Luca
    Pugliese, Mariagabriella
    EUROPEAN PHYSICAL JOURNAL PLUS, 2023, 138 (09):
  • [22] Dosimetry Approach for a Retrospective Epidemiological Study On Eye Lens Dose to Interventional Cardiologists and the Occurrence of Radiation-Induced Lens Opacities
    Farah, J.
    Struelens, L.
    Jacob, S.
    Schnelzer, M.
    Auvinen, A.
    Vanhavere, F.
    Clairand, I.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [23] Hp(3) vs TLD-100 for eye lens dosimetry in interventional radiology procedures: a preliminary study
    Francesco Manna
    Gianleonardo De Nardellis
    Patrizio Antonio Carmosino
    Fabrizio Ambrosino
    Umberto Caruso
    Marco Correra
    Francesco Fiore
    Giuseppe La Verde
    Luca Tarotto
    Mariagabriella Pugliese
    The European Physical Journal Plus, 138
  • [24] A Method for Eye Lens Dose Estimation During Fluoroscopically-Guided Neuro-Interventional Procedures
    Xiong, Z.
    Kilian-Meneghin, J.
    Vijayan, S.
    Guo, C.
    Rudin, S.
    Bednarek, D.
    MEDICAL PHYSICS, 2017, 44 (06) : 3198 - 3198
  • [25] Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery
    Apelmann, Christian
    Kowald, Birgitt
    Weinrich, Nils
    Dischinger, Jens
    Nienhaus, Albert
    Seide, Klaus
    Martens, Heiko
    Juergens, Christian
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (20)
  • [26] Eye Lens Dose Reduction of Radiologists in Interventional Procedures with Lead Glasses
    Hu, P.
    Zhuo, W.
    Liu, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3719 - 3719
  • [27] Eye lens dosimetry and the study on radiation cataract in interventional cardiologists
    Matsubara, Kosuke
    Lertsuwunseri, Vorarit
    Srimahachota, Suphot
    Krisanachinda, Anchali
    Tulvatana, Wasee
    Khambhiphant, Bharkbhum
    Sudchai, Waraporn
    Rehani, Madan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 232 - 235
  • [28] Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels
    Antic, V.
    Ciraj-Bjelac, O.
    Rehani, M.
    Aleksandric, S.
    Arandjic, D.
    Ostojic, M.
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 276 - 284
  • [29] Absorbed dose to the eye lens during dental radiography
    Takao Kanzaki
    Yasuyuki Takahashi
    Kazuma Yarita
    Oral Radiology, 2017, 33 : 246 - 250
  • [30] Absorbed dose to the eye lens during dental radiography
    Kanzaki, Takao
    Takahashi, Yasuyuki
    Yarita, Kazuma
    ORAL RADIOLOGY, 2017, 33 (03) : 246 - 250