Eye lens dose in spine surgeons during myelography procedures: a dosimetry study

被引:0
|
作者
Nagamoto, Keisuke [1 ]
Kawachino, Tomonori [1 ]
Suetsugu, Yoshiki [1 ]
Saruwatari, Hiromi [1 ]
Nihei, Shun-ichi [2 ]
Kunugita, Naoki [3 ]
机构
[1] Hosp Univ Occupat & Environm Hlth, Dept Radiol, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Emergency & Intens Care Med, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[3] Univ Occupat & Environm Hlth, Dept Occupat & Community Hlth, Nursing Sch Hlth Sci, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
关键词
3 mm dose equivalent; Hp(3); lens dose; myelography; spine surgeons; radio-photoluminescence glass dosimeters; x-ray tube system; INTERVENTIONAL RADIOLOGY; RADIATION-EXPOSURE; FLUOROSCOPY; TRIAL; CT;
D O I
10.1088/1361-6498/ad0b3a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the eye lens dose (3 mm dose equivalent [Hp(3)]) received by spine surgeons during myelography and evaluate the effectiveness of radiation-protective glasses and x-ray tube system positioning in reducing radiation exposure. This study included spine surgeons who performed myelography using over- or under-table x-ray tube systems. Hp(3) was measured for each examination using a radio-photoluminescence glass dosimeter (GD-352M) mounted on radiation-protective glass. This study identified significantly high Hp(3) levels, especially in the right eye lens in spinal surgeons. The median Hp(3) values in the right eye were 524 (391-719) and 58 (42-83) mu Sv/examination for over- and under-table x-ray tube systems, respectively. Further, Hp(3)AK, which was obtained by dividing the cumulative air kerma from Hp(3), was 8.09 (6.69-10.21) and 5.11 (4.06-6.31) mu Sv mGy-1 for the over- and under-table x-ray tube systems, respectively. Implementing radiation-protective glasses resulted in dose reduction rates of 54% (50%-57%) and 54% (51%-60%) for the over- and under-table x-ray tube systems, respectively. The use of radiation protection glasses significantly reduced the radiation dose in the eye lens during myelography, with the most effective measures being the combination of using radiation protection glasses and an under-table x-ray tube system.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Eye lens dosimetry in anesthesiology: a prospective study
    Bart Vaes
    Karel Van Keer
    Lara Struelens
    Werner Schoonjans
    Ivo Nijs
    Jan Vandevenne
    Sven Van Poucke
    Journal of Clinical Monitoring and Computing, 2017, 31 : 303 - 308
  • [12] DOSIMETRY FOR THE LENS OF THE EYE, APPLICATIONS FOR MEDICAL STAFF INVOLVED IN INTERVENTIONAL PROCEDURES
    Geber, Therese
    Gunnarsson, Mikael
    Mattsson, Soren
    MEDICAL PHYSICS IN THE BALTIC STATES, 2010, (02): : 105 - 108
  • [13] Eye lens dosimetry in anesthesiology: a prospective study
    Vaes, Bart
    Van Keer, Karel
    Struelens, Lara
    Schoonjans, Werner
    Nijs, Ivo
    Vandevenne, Jan
    Van Poucke, Sven
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (02) : 303 - 308
  • [14] Real-time eye lens dose monitoring during cerebral angiography procedures
    M. J. Safari
    J. H. D. Wong
    K. A. A. Kadir
    N. K. Thorpe
    D. L. Cutajar
    M. Petasecca
    M. L. F. Lerch
    A. B. Rosenfeld
    K. H. Ng
    European Radiology, 2016, 26 : 79 - 86
  • [15] Development of an applicator for eye lens dosimetry during radiotherapy
    Park, J. M.
    Lee, J.
    Kim, H. S.
    Ye, S-J
    Kim, J-I
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1042):
  • [16] Real-time eye lens dose monitoring during cerebral angiography procedures
    Safari, M. J.
    Wong, J. H. D.
    Kadir, K. A. A.
    Thorpe, N. K.
    Cutajar, D. L.
    Petasecca, M.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    Ng, K. H.
    EUROPEAN RADIOLOGY, 2016, 26 (01) : 79 - 86
  • [17] Eye lens equivalent dose in interventional neuroradiology based on OSL dosimetry
    Patino, G.
    Ballester, F.
    Vijande, J.
    Gras, P.
    Villaescusa, J.
    Campayo, J.
    2016 GLOBAL MEDICAL ENGINEERING PHYSICS EXCHANGES/PAN AMERICAN HEALTH CARE EXCHANGES (GMEPE/PAHCE), 2016,
  • [18] Extremity and eye lens dosimetry for medical staff performing vertebroplasty and kyphoplasty procedures
    Struelens, L.
    Schoonjans, W.
    Schils, F.
    De Smedt, K.
    Vanhavere, F.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (03) : 635 - 645
  • [19] Protected and unprotected radiation exposure to the eye lens of vascular surgeons during endovascular procedures in hybrid operating rooms
    Jungi, S.
    Schweizer, V.
    Ante, M.
    Attigah, N.
    Geisbuesch, P.
    Hoedlmoser, H.
    Boeckler, D.
    BRITISH JOURNAL OF SURGERY, 2021, 108 : 21 - 21
  • [20] FACTORS AFFECTING THE RADIATION-DOSE TO THE LENS OF THE EYE DURING CARDIAC-CATHETERIZATION PROCEDURES
    PRATT, TA
    SHAW, AJ
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (784): : 346 - 350