Film cooling effectiveness of a leading-edge cooling array of a rotating turbine blade with twist

被引:9
|
作者
Han, Feng [1 ,2 ]
Bi, Shuai [1 ]
Mao, Jun-kui [1 ]
Li, Hai-wang [3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Energy & Power Engn, Nanjing 210016, Jiangsu, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Integrated Energy Inst, Nanjing 210016, Jiangsu, Peoples R China
[3] Beihang Univ, Natl Key Lab Sci & Technol Aero Engines Aerothermo, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Leading edge; Rotating blade; Hole pitch-to-diameter ratio; Film cooling; Effectiveness; FREE-STREAM TURBULENCE; HEAT-TRANSFER; COMPOUND ANGLE; BLOWING RATIO; PERFORMANCE; HOLES; MODEL; SIMULATION; REGION; ROWS;
D O I
10.1016/j.applthermaleng.2023.120175
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental investigations have been carried out to study the effects of the film hole pitch-to-diameter ratio (P/ D), blowing ratio (M) and rotation on the leading edge (LE) region film cooling performance of a twist turbine blade under rotating conditions. The thermochromic liquid crystal (TLC) technology was applied to measure the LE surface temperature. All experiments were performed at the rotating speed of 574 r/min with the average M varying from 0.5 to 1.25. The Reynolds number (Re) based on the mainstream velocity of the turbine outlet and the test blade chord length was maintained at 6.4 x 104. The coolant-to-mainstream density ratio (DR) was 1.04 with N2 as the coolant. The hole pitch-to-diameter ratios tested were P/D = 2.5, P/D = 3.75 and P/D = 5.0, respectively. The experimental results indicate that both the P/D and the M play an indispensable role in influencing the film cooling performance on the LE under rotating conditions. Regardless of the value of film hole P/D, the spanwise average film cooling effectiveness (eta) increases gradually with increasing the M on the LE region under rotating conditions. For all hole P/D cases, the experimental results indicate that the level of spanwise average eta provided by the PS region (-4.3 < X/D < 0) is higher than that provided by the SS region (0 < X/D < 3.75) in the LE region when the M was unchanged under rotating conditions. For all M cases, the spanwise average eta indicates the decreasing trend with increasing the hole P/D. For all hole P/D cases, the area average eta increases gradually with increasing the M. For all M cases, the area average eta decreases gradually with increasing the hole P/D. And the reduction is sometimes non-linear to the P/D change. Under the condition that the coolant jet mass flow rate (MFR) remains constant, the area average eta decreases gradually with increasing the hole P/D.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Convective film cooling over a representative turbine blade leading-edge
    Thakur, S
    Wright, J
    Shyy, W
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (12) : 2269 - 2285
  • [2] Experimental investigation on the effects of rotation and the blowing ratio on the leading-edge film cooling of a twist turbine blade
    Li, Hai-wang
    Han, Feng
    Ma, Yi-wen
    Wang, Hai-chao
    Zhou, Zhi-yu
    Tao, Zhi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 129 : 47 - 58
  • [3] Influence of leading-edge lateral injection angles on the film cooling effectiveness of a gas turbine blade
    Abbès Azzi
    Bassam Ali Jubran
    Heat and Mass Transfer, 2004, 40 : 501 - 508
  • [4] Influence of leading-edge lateral injection angles on the film cooling effectiveness of a gas turbine blade
    Azzi, A
    Ali Jubran, B
    HEAT AND MASS TRANSFER, 2004, 40 (6-7) : 501 - 508
  • [5] AN EXPERIMENTAL-STUDY OF FILM-COOLING EFFECTIVENESS NEAR THE LEADING-EDGE OF A TURBINE BLADE
    SALCUDEAN, M
    GARTSHORE, I
    ZHANG, K
    MCLEAN, I
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1994, 116 (01): : 71 - 79
  • [6] SHOWERHEAD FILM COOLING MECHANISM AND SUPERPOSITION CHARACTERISTICS OF TURBINE BLADE LEADING-EDGE
    Li, Bing-ran
    Zhou, Tian-liang
    Liu, Cun-liang
    Ye, Lin
    Zhang, Fan
    PROCEEDINGS OF ASME TURBO EXPO 2024: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2024, VOL 7, 2024,
  • [7] Effect of rotation on the leading-edge region film cooling of a twisted turbine blade
    Han F.
    Li H.
    Ma Y.
    Tao Z.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2019, 34 (06): : 1352 - 1363
  • [8] Effect of the Injection Angle on the Leading Edge Film Cooling of a Rotating Turbine Blade
    Han, Feng
    Li, Hai-Wang
    1600, Science Press (41): : 320 - 328
  • [9] LEADING-EDGE INJECTION FOR FILM COOLING OF TURBINE VANES
    HANUS, GJ
    ECUYER, MRL
    JOURNAL OF ENERGY, 1977, 1 (01): : 44 - 49
  • [10] Single-hole film cooling on a turbine-blade leading-edge model
    Mishra, Suman
    Wanchoo, Rohan
    Ghia, Urmila
    Ghia, Kirti N.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 8, PTS A AND B: HEAT TRANSFER, FLUID FLOWS, AND THERMAL SYSTEMS, 2008, : 743 - 749