Coded aperture and Compton imaging for the development of 225Ac-based radiopharmaceuticals

被引:5
|
作者
Frame, Emily [1 ]
Bobba, Kondapa [2 ]
Gunter, Donald [3 ,4 ]
Mihailescu, Lucian [5 ]
Bidkar, Anil [2 ]
Flavell, Robert [2 ,6 ]
Vetter, Kai [1 ,4 ]
机构
[1] Univ Calif Berkeley, Dept Nucl Engn, Berkeley, CA 94502 USA
[2] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
[3] Gunter Phys Inc, Lisle, IL USA
[4] Lawrence Berkeley Natl Lab, Appl Nucl Phys Grp, Berkeley, CA 94502 USA
[5] Ziteo Med Inc, Pleasant Hill, CA USA
[6] Univ Calif San Francisco, Dept Pharmaceut Chem, San Francisco, CA USA
关键词
Actinium-225; coded aperture imaging; Compton imaging; small-animal molecular imaging; targeted alpha-particle therapy; SPECT; THERAPY;
D O I
10.1002/mp.16717
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Targeted alpha-particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is Ac-225. The development of Ac-225-based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage.Purpose: The ability to directly image the daughters, namely Fr-221 and Bi-213, via their gamma-ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations.Methods: As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218-keV gamma-ray emission of Fr-221 and the latter suited to the 440-keV gamma-ray emission of Bi-213.Results: This work includes coded aperture images of Fr-221 and Compton images of Bi-213 in tumor-bearing mice injected with Ac-225-based radiopharmaceuticals.Conclusions: These results are the first demonstration of visualizing and quantifying the Ac-225 daughters in small animals through the application of coded aperture and Compton imaging.
引用
收藏
页码:6454 / 6468
页数:15
相关论文
共 50 条
  • [1] COMPTON-SCATTERING TOMOGRAPHY BY CODED APERTURE IMAGING
    PLATZER, H
    HOFER, J
    GANSSEN, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 129 - 129
  • [2] Compton telescope with a coded aperture mask:: Imaging with the INTEGRAL/IBIS compton mode
    Forot, M.
    Laurent, P.
    Lebrun, F.
    Limousin, O.
    ASTROPHYSICAL JOURNAL, 2007, 668 (02): : 1259 - 1265
  • [3] Development of Ac-225 Radiopharmaceuticals: TRIUMF Perspectives and Experiences
    Robertson, Andrew Kyle Henderson
    Ramogida, Caterina Fortunata
    Schaffer, Paul
    Radchenko, Valery
    CURRENT RADIOPHARMACEUTICALS, 2018, 11 (03) : 156 - 172
  • [4] Hybrid coded aperture and Compton imaging using an active mask
    Schultz, L. J.
    Wallace, M. S.
    Galassi, M. C.
    Hoover, A. S.
    Mocko, M.
    Palmer, D. M.
    Tornga, S. R.
    Kippen, R. M.
    Hynes, M. V.
    Toolin, M. J.
    Harris, B.
    McElroy, J. E.
    Wakeford, D.
    Lanza, R. C.
    Horn, B. K. P.
    Wehe, D. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (02): : 267 - 274
  • [5] Design of a Coded Aperture Compton Telescope Imaging System (CACTIS)
    Volkovskii, Alexander
    Clajus, Martin
    Gottesman, Stephen R.
    Malik, Hans
    Schwartz, Kenneth
    Tumer, Evren
    Tumer, Tumay
    Yin, Shi
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XII, 2010, 7805
  • [6] Gamma Imaging Using Hybrid Coded-Aperture and Compton Scatter Imaging
    Montz, B.
    Hayward, J.
    Ramsey, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E209 - E209
  • [7] Coded-Aperture Compton Camera for Gamma-Ray Imaging
    Farber, Aaron M.
    Williams, John G.
    ISRD 15 - INTERNATIONAL SYMPOSIUM ON REACTOR DOSIMETRY, 2016, 106
  • [8] A Sparse Uncollimated γ Counter Network for In Vivo Dose Reconstructionin 225Ac-Based Targeted Alpha Therapy
    Lall, R.
    Bobba, K. N.
    Bidkar, A.
    Seo, Y.
    Flavell, R.
    Niknejad, A.
    Anwar, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : S109 - S109
  • [9] Coded aperture and Compton imaging capability of spherical detector system design based on GAGG scintillators: A Monte Carlo study
    Liang, Xiuzuo
    Shuai, Lei
    Liu, Yantao
    Li, Xin
    Kong, Lingqin
    Wei, Qing
    Wang, Yingjie
    Zhang, Zhiming
    Huang, Xianchao
    Hu, Xuanhou
    Zhang, Yiwen
    Yu, Yue
    Wei, Cunfeng
    Wei, Long
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1044
  • [10] A Novel Gamma-Ray Imaging System Using a Coded-Aperture Compton Camera
    Farber, Aaron M.
    Williams, John G.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 450 - 454