An air-cooled system with a control strategy for efficient battery thermal management

被引:28
|
作者
Chen, Kai [1 ]
Zhang, Zhenli [1 ]
Wu, Bingheng [2 ]
Song, Mengxuan [3 ,4 ]
Wu, Xiaoling [5 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Minist Educ, Key Lab Enhanced Heat Transfer & Energy Conservat, Guangzhou 510640, Guangdong, Peoples R China
[2] Guangzhou Railway Polytech, Sch Mech & Elect Engn, Guangzhou 510430, Guangdong, Peoples R China
[3] Shanghai Polytech Univ, Sch Energy & Mat, Shanghai Key Lab Engn Mat Applicat & Evaluat, Shanghai 201209, Peoples R China
[4] Shanghai Engn Res Ctr Adv Thermal Funct Mat, Shanghai Thermophys Properties Big Data Profess Te, Shanghai 201209, Peoples R China
[5] South China Univ Technol, Sch Food Sci & Engn, Lab Appl Biocatalysis, Guangzhou 510640, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal management of battery packs; Air-cooled system; Control strategy; Uneven channel widths; LITHIUM-ION BATTERY; POWER BATTERY; OPTIMIZATION; MODULE; DESIGN; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2023.121578
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-cooled systems are widely used in electric vehicles for the thermal management of battery packs. Due to the low specific heat capacity of air, design of air-cooled systems is required to improve the temperature uniformity of battery packs. However, structural design of the system cannot meet the requirement of battery thermal management under varying operating conditions. In this study, a parallel air-cooled system with a control strategy is developed for efficient cooling of battery packs under varying operating conditions. The performance of the air-cooled systems with different single flow types is investigated numerically, with the results verified by experiments. A control strategy based on the temperature difference among battery cells is proposed for the system with J-type flow, and the mechanism by which traditional systems fail in temperature difference control is revealed. To address this issue, an efficient thermal management system that integrates different flow types is proposed and relevant control strategy is developed, with decreased widths of the parallel channels on both ends. The proposed system with the control strategy reduces the temperature difference among battery cells by switching the flow type on demand and guiding more cooling air to the battery cell with high temperature. The numerical results of the cases with high current discharge rate and with varying random operating conditions show that the developed system enables the temperature difference to be controlled below 0.5 K after several switches of flow type. The average temperature difference among the battery cells in the developed system is reduced by more than 67% compared to that with J-type flow alone. The proposed system with the relevant control strategy is efficient for thermal management of battery packs under varying operating conditions.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Construction of effective symmetrical air-cooled system for battery thermal management
    Chen, Kai
    Chen, Yiming
    She, Yiqi
    Song, Mengxuan
    Wang, Shuangfeng
    Chen, Lin
    [J]. APPLIED THERMAL ENGINEERING, 2020, 166
  • [2] Configuration optimization of battery pack in parallel air-cooled battery thermal management system using an optimization strategy
    Chen, Kai
    Wang, Shuangfeng
    Song, Mengxuan
    Chen, Lin
    [J]. APPLIED THERMAL ENGINEERING, 2017, 123 : 177 - 186
  • [3] Structure optimization of parallel air-cooled battery thermal management system
    Chen, Kai
    Wang, Shuangfeng
    Song, Mengxuan
    Chen, Lin
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 111 : 943 - 952
  • [4] Design of flow pattern in air-cooled battery thermal management system
    Chen, Kai
    Hou, Junsheng
    Wu, Xiaoling
    Chen, Yiming
    Song, Mengxuan
    Wang, Shuangfeng
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (06) : 9541 - 9554
  • [5] Cooling performance optimization of air-cooled battery thermal management system
    Wang, Meiwei
    Teng, Shiyang
    Xi, Huan
    Li, Yuquan
    [J]. APPLIED THERMAL ENGINEERING, 2021, 195
  • [6] Optimization design of a parallel air-cooled battery thermal management system with spoilers
    Zhang, Furen
    Lin, Aizhen
    Wang, Pengwei
    Liu, Peiwen
    [J]. APPLIED THERMAL ENGINEERING, 2021, 182
  • [7] Design of the cell spacings of battery pack in parallel air-cooled battery thermal management system
    Chen, Kai
    Chen, Yiming
    Li, Zeyu
    Yuan, Fang
    Wang, Shuangfeng
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 393 - 401
  • [8] Thermal management system for air-cooled battery packs with flow-disturbing structures
    Sahin, R. Cagtay
    Gocmen, Sinan
    Cetkin, Erdal
    [J]. JOURNAL OF POWER SOURCES, 2022, 551
  • [9] Structure optimization of air-cooled battery thermal management system based on neural network
    Chen, Jiahui
    Xuan, Dongji
    Chen, Cong
    Chen, Jianlong
    Shen, Yunde
    [J]. IONICS, 2023, 29 (07) : 2773 - 2782
  • [10] Design of Parallel Air-Cooled Battery Thermal Management System through Numerical Study
    Chen, Kai
    Li, Zeyu
    Chen, Yiming
    Long, Shuming
    Hou, Junsheng
    Song, Mengxuan
    Wang, Shuangfeng
    [J]. ENERGIES, 2017, 10 (10):