A study on how efficient measures for secondary district heating system performance can be encouraged by motivational tariffs

被引:3
|
作者
Lygnerud, Kristina [1 ,2 ]
Nyberg, Theo [2 ]
Nilsson, Anna [2 ]
Fabre, Antoine [3 ]
Stabat, Pascal [3 ]
Duchayne, Chloe [4 ]
Gavan, Valentin [4 ]
机构
[1] Lund Univ, Energy Sci, John Ericssons Vag 3, S-22363 Lund, Sweden
[2] Swedish Environm Res Inst, IVL, Vallhallavagen 81, S-11427 Stockholm, Sweden
[3] PSL Res Univ, CES Ctr Energy Efficiency Syst, MINES Paris, 60 Blvd St Michel, F-75006 Paris, France
[4] ENGIE R&I, Lab CRIGEN, 4 Rue Josephine Baker, F-93240 Stains, France
关键词
District heating; Secondary system; Retrofit actions; Motivational tariff; Price model; ENERGY; MODEL;
D O I
10.1186/s13705-023-00417-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
BackgroundDistrict Heating (DH) is a technology that provides heating and domestic hot water to buildings and is an important technology for supporting the European energy transition. As such the heating systems increasingly resort to renewable heat sources and waste heat, it is even more important that they operate in the most efficient way possible. DH companies have access to the primary network of which they can impact system performance. To maximize the efficiency of the system, however, it is important that the system at the building level, known as the secondary system, is also efficient; otherwise, overall system efficiency is reduced. To increase system efficiency, return temperatures from the secondary system into the primary system have been targeted through motivational tariffs. There is limited information on how to establish a motivational tariff that motivates the customer to improve both the primary and secondary systems, which is a gap that this paper aims to fill.ResultsIn this paper, the impacts of retrofit actions in secondary systems are assessed through simulations. The identified relevant refurbishment measures to lower the return temperature to the primary system are variable flow pumps, low-temperature radiators, parallel heat exchangers, and a pass-through DHW system. Apart from simulated refurbishments, we also identify that the secondary system sometimes generates excess heat, which is valuable to recover, especially during peak load periods for the primary system. Hence, motivational tariffs targeting secondary system efficiency should also encompass an incentive for the customer to make use of waste heat in the secondary circuit to lower peak demand for the DH system.ConclusionsTo date, the most commonly used parameters introduced to customers are linked to the flow of water through the customer's asset and the bonus malus principle. The results from simulations show that DH companies can introduce additional parameters to support customers in guiding their secondary system to perform more efficiently. Increased overall system efficiency has a positive impact on both costs and emissions.
引用
收藏
页数:15
相关论文
共 20 条
  • [1] A study on how efficient measures for secondary district heating system performance can be encouraged by motivational tariffs
    Kristina Lygnerud
    Theo Nyberg
    Anna Nilsson
    Antoine Fabre
    Pascal Stabat
    Chloé Duchayne
    Valentin Gavan
    Energy, Sustainability and Society, 13
  • [2] EFFICIENT SOLAR TECHNIQUE FOR BUILDINGS CONNECTED TO THE DISTRICT HEATING SYSTEM. INDICATORS OF PERFORMANCE
    Soimosan, Teodora-Melania
    Felseghi, Raluca-Andreea
    ENERGY AND CLEAN TECHNOLOGIES CONFERENCE PROCEEDINGS, SGEM 2016, VOL III, 2016, : 251 - 258
  • [3] Performance Analysis of a Hybrid District Heating System: A Case Study of a Small Town in Croatia
    Mikulandric, Robert
    Krajacic, Goran
    Duic, Neven
    Khavin, Gennadii
    Lund, Henrik
    Mathiesen, Brian Vad
    Ostergaard, Poul
    JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES, 2015, 3 (03): : 282 - 302
  • [4] REQUIREMENT OF HEAT PUMP SYSTEM PERFORMANCE FOR AN ENERGY EFFICIENT SEAWATER-SOURCE HEAT PUMP DISTRICT HEATING SYSTEM
    Shu, Haiwen
    Lin Duanmu
    Li, Xiangli
    Zhu, Yingxin
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1644 - 1651
  • [5] SIMULATION OF ENERGY CONSERVATION MEASURES AND ITS IMPLICATIONS ON A COMBINED HEAT AND POWER DISTRICT HEATING SYSTEM: A CASE STUDY
    Elci, Mehmet
    Narmsara, Sattaya
    Kagerer, Florian
    Herkel, Sebastian
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 104 - 111
  • [6] A feasibility and performance assessment of a low temperature district heating system - A North Japanese case study
    Baldvinsson, Ivar
    Nakata, Toshihiko
    ENERGY, 2016, 95 : 155 - 174
  • [7] Study on Efficient Heat Interchange Control in District Heating and Cooling System with Multiple Sub-plants
    Kitora, Hisataka
    Akashi, Yasunori
    Lim, Jongyeon
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 861 - 868
  • [8] Performance and thermo-economic assessments of geothermal district heating system: A case study in Afyon, Turkey
    Kecebas, Ali
    RENEWABLE ENERGY, 2011, 36 (01) : 77 - 83
  • [9] Energy performance and economic feasibility of hot spring-based district heating system - A case study
    Kavian, Soheil
    Hakkaki-Fard, Ali
    Mosleh, Hassan Jafari
    ENERGY, 2020, 211 (211)
  • [10] How Can the Sustainable Motivational Effect of Equity Incentives on Corporate Performance Be Exploited?-A Study Based on the Moderating Effect of Aspiration Level
    Tang, Lu
    Zhang, Shihan
    Ding, Chenhui
    Huan, Jinyao
    SUSTAINABILITY, 2022, 14 (24)