Handheld virus concentration method using a hollow fiber filter module

被引:1
|
作者
Higuchi, Shinsuke [1 ]
Satou, Tatsuki [1 ]
Uchida, Yuki [1 ]
机构
[1] Takeda Pharmaceut Co Ltd, Global Vaccine Business Unit, Japan CMC, Vaccine Operat CMC, 4720 Takeda, Yamaguchi 7438502, Japan
关键词
Ultrafiltration; Tangential flow filtration; Concentration; Virus; Hollow fiber filter; Zika virus; Flavivirus;
D O I
10.1016/j.mex.2023.102126
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A virus concentration method is required for viral vaccine manufacturing and virus-related re-search. However, concentration methods, such as ultracentrifugation, often require capital in-vestment. We report a simple and easy-to-use handheld syringe method for virus concentration using a hollow fiber (HF) filter module, which can be applicable to viruses of different sizes, with-out incorporating any special machines or reagents. This virus concentration method does not use pumps, which might cause shear stress for virus particles; therefore, it is useful for stress-sensitive virus particles, and virus-like particles, as well as other proteins.The clarified harvest of flavivirus (Zika virus) was concentrated using an HF filter module and compared with a centrifugal ultrafiltration device (CUD) for demonstration of the HF filter method. The HF filter method achieved concentration of the virus solution in less time than the CUD. The yield comparison of the recovered virus solution indicated that recovery from the developed method was comparable to using the CUD, and infectivity was maintained throughout.& BULL; The Zika virus was concentrated from 200 mL to 5 mL within 45 min using the HF filter and handheld syringe module method.& BULL; The handheld HF filter method may be applicable to stress-sensitive viruses and proteins of different sizes.& BULL; The virus concentration process should be conducted in a safety cabinet, which is preferred for virus containment.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Evaluation of the impact of hollow fiber pore size and membrane material on virus concentration using a handheld hollow fiber method
    Higuchi, Shinsuke
    Satou, Tatsuki
    Uchida, Yuki
    JOURNAL OF VIROLOGICAL METHODS, 2025, 332
  • [2] VIRUS CONCENTRATION USING HOLLOW FIBER MEMBRANES
    BELFORT, G
    ROTEM, Y
    KATZENELSON, E
    WATER RESEARCH, 1975, 9 (01) : 79 - 85
  • [3] VIRUS CONCENTRATION USING HOLLOW FIBER MEMBRANES .2.
    BELFORT, G
    ROTEM, Y
    KATZENELSON, E
    WATER RESEARCH, 1976, 10 (04) : 279 - 284
  • [4] ACETIC-ACID PRODUCTION USING A FERMENTER EQUIPPED WITH A HOLLOW FIBER FILTER MODULE
    PARK, YS
    OHTAKE, H
    TODA, K
    FUKAYA, M
    OKUMURA, H
    KAWAMURA, Y
    BIOTECHNOLOGY AND BIOENGINEERING, 1989, 33 (07) : 918 - 923
  • [6] A new method for supplying low radon air by using a hollow fiber module
    Iida, T
    Kato, T
    NATURAL RADIATION ENVIRONMENT VII, 2005, 7 : 497 - 505
  • [7] VIRUS CONCENTRATION BY HOLLOW FIBER MEMBRANES - WHERE TO NOW
    GRABOW, WOK
    BELFORT, G
    PROGRESS IN WATER TECHNOLOGY, 1978, 10 (1-2): : 377 - 377
  • [8] THE INFLUENCE OF FIBER DENSITY ON THE ASSESSMENT OF FIBER CONCENTRATION USING THE MEMBRANE-FILTER METHOD
    CHERRIE, J
    JONES, AD
    JOHNSTON, AM
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1986, 47 (08): : 465 - 474
  • [9] Continuous culture systems involving Zymomonas mobilis and a hollow fiber filter module
    Hilary, ZD
    Ishizaki, A
    BIOTECHNOLOGY TECHNIQUES, 1997, 11 (08) : 537 - 541
  • [10] CONCENTRATION OF COLLOIDAL SOLUTION BY SINGLE-PASS ULTRAFILTRATION USING HOLLOW-FIBER MEMBRANE MODULE
    IRITANI, E
    MURAKAMI, Y
    MURASE, T
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1995, 28 (05) : 614 - 616