Method of adaptive wide dynamic range gas concentration detection based on optimized direct absorption spectroscopy

被引:9
|
作者
Wang, Qianjin [1 ,2 ]
Sun, Pengshuai [2 ]
Zhang, Zhirong [1 ,2 ,3 ,4 ]
Cai, Yongjun [5 ]
Huang, Wenbiao [1 ,2 ]
Pang, Tao [2 ]
Wu, Bian [2 ]
Xia, Hua [2 ,3 ]
Guo, Qiang [2 ]
机构
[1] Univ Sci & Technol China, Sch Environm Sci & Optoelect Technol, Hefei 230026, Anhui, Peoples R China
[2] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Anhui Prov Key Lab Photon Devices & Mat, HFIPS, Hefei 230031, Anhui, Peoples R China
[3] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, HFIPS, Hefei 230031, Anhui, Peoples R China
[4] Adv Laser Technol Lab Anhui Prov, Hefei 230037, Anhui, Peoples R China
[5] PipeChina Gen Acad Sci &Technol, Langfang 065000, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
TUNABLE DIODE-LASER; MU-M WAVELENGTH; SENSOR; TEMPERATURE; CH4;
D O I
10.1364/OE.487889
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
For wide dynamic range gas concentration detection based on tunable diode laser absorption spectroscopy (TDLAS), direct absorption spectroscopy (DAS) and wavelength modulation spectroscopy (WMS) are usually used in combination. However, in some application scenarios such as high-speed flow field detection, natural gas leakage, or industrial production, the requirements of wide-range, fast response and calibration-free must be met. Taking applicability and cost of TDALS-based sensor into consideration, a method of optimized direct absorption spectroscopy (ODAS) based on signal correlation and spectral reconstruction is developed in this paper. This method can achieve adaptive selection of the optimal benchmark spectrum for spectral reconstruction. Moreover, methane (CH4) is taken as an example to carry out the experimental verification. Experimental results proved that the method satisfies wide dynamic range detection of more than 4 orders of magnitude. It is worth noting that when measuring large absorbance with concentration of 75 x 104 ppm with DAS and ODAS method, respectively, the maximum value of residual is reduced from 3.43 to 0.07. Furthermore, whether measuring gas of small or large absorbance with different concentrations, which vary from 100 ppm to 75 x 104 ppm, the correlation coefficient between standard concentrations and inverted concentrations is 0.997, showing the linear consistency of the method in wide dynamic range. In addition, the absolute error is 1.81 x 104 ppm when measuring large absorbance of 75 x 104 ppm. It greatly improves the accuracy and reliability with the new method. In summary, the ODAS method can not only fulfill the measurement of gas concentration in wide range, but also further expand the application prospects of TDLAS. (c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:16770 / 16780
页数:11
相关论文
共 50 条
  • [1] Wide-range multi-gas detection method based on wavelength modulation spectroscopy and direct absorption spectroscopy
    Zhao X.
    Sun P.
    Zhang Z.
    Wang Q.
    Pang T.
    Sun M.
    Zhuang F.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2023, 52 (01):
  • [2] Wide dynamic detection range of methane gas based on enhanced cavity absorption spectroscopy
    Wang, Yu
    Ding, Bo-Kun
    Wang, Kun-Yang
    Mei, Jiao-Xu
    Han, Ze-Lin
    Tan, Tu
    Gao, Xiao-Ming
    CHINESE PHYSICS B, 2022, 31 (04)
  • [3] Wide dynamic detection range of methane gas based on enhanced cavity absorption spectroscopy
    汪玉
    丁伯坤
    王坤阳
    梅教旭
    韩泽林
    谈图
    高晓明
    Chinese Physics B, 2022, (04) : 206 - 210
  • [4] Wide‑Range Gas Concentration Detection Method Based on Nonlinear Characteristics in Wavelength Modulation Spectroscopy
    Wang Q.
    Sun P.
    Zhang Z.
    Cai Y.
    Huang W.
    Pang T.
    Xia H.
    Wu B.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2024, 51 (05):
  • [5] Gas concentration detection method based on infrared absorption spectroscopy technology
    Liu, Yong-Ping
    Wang, Xia
    Li, Shuai-Shuai
    Hu, Ling
    Guangzi Xuebao/Acta Photonica Sinica, 2015, 44 (01):
  • [6] Ultra-wide-dynamic-range gas sensing by optical pathlength multiplexed absorption spectroscopy
    Lou, Xiutao
    Feng, Yabo
    Yang, Shunhu
    Dong, Yongkang
    PHOTONICS RESEARCH, 2021, 9 (02) : 193 - 201
  • [7] Ultra-wide-dynamic-range gas sensing by optical pathlength multiplexed absorption spectroscopy
    XIUTAO LOU
    YABO FENG
    SHUNHU YANG
    YONGKANG DONG
    Photonics Research, 2021, 9 (02) : 193 - 201
  • [8] Wide Range Analysis of Absorption Spectroscopy Ozone Gas Sensor
    Yaacob, Maslina
    Salim, Mohd Rashidi
    Marcus, Tay Ching En
    David, Micheal
    Hussin, Nabihah
    Ibrahim, Mohd Haniff
    Ngajikin, Nor Hafizah
    Azmi, Asrul Izam
    JURNAL TEKNOLOGI, 2015, 73 (03):
  • [9] Gas Concentration Inversion Method Based on Calibration of Direct Absorption Peak Value
    Deng Yao
    Tang Wen
    Li Zhenghui
    Zhong Shangwen
    Zou Lichang
    Lu Zhimin
    Lin Jian
    Yao Shunchun
    LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (03)
  • [10] Solving the overlapped absorbance profile in gas detection by Lorentz distribution solution based on direct absorption spectroscopy method
    Lai, Linquan
    Yin, Kaiwen
    Tang, Jiale
    Fu, Zenan
    Chen, Kongtao
    Zhang, Shunqin
    Jia, Fuqiang
    Qiao, Dun
    Fan, Yuanlong
    Li, Kang
    Copner, Nigel
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 281