Numerical Study on the Application of Pressure-Swirl Atomizing Nozzles in a Direct Air Cooling Condenser of the Power Plant

被引:0
|
作者
Liu, Tianyun [1 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
关键词
pressure-swirl atomizing nozzle; numerical study; heat transfer; spray humidification; direct air cooling condenser; condensation; energy efficiency; energy systems; heat and mass transfer; heat transfer enhancement; HEAT-TRANSFER; WATER SPRAY; PERFORMANCE; SIMULATION;
D O I
10.1115/1.4063921
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a pressure-swirl atomizing nozzle was proposed to improve the atomization characteristics and enhance the heat transfer characteristics. By modifying the structural parameters of the nozzle, the effect of angles of inclined holes on the swirl plate on the heat transfer characteristics was studied, and the structure of the nozzle was optimized based on fluent software. The corresponding relationship between the pressure difference between the inlet and outlet of the nozzle and the flowrate was obtained, which provides a basis for the parameter setting of the discrete phase model. The nozzle was then applied to a spray humidification system of a direct air cooling unit in the power plant. The influences of nozzle arrangements and spray directions on the vacuum degree of the system were studied. The results of the numerical study show that the nozzle with the angle of inclined holes at 45 deg not only has the highest heat transfer efficiency but also has the highest heat transfer uniformity among all the simulated cases. In the air cooling unit of the power plant, when the nozzles are arranged in staggered rows and the angle between the spray direction and the positive direction along the height is kept at 15 deg, the heat transfer performance of spray humidification is the best. The vacuum degree of the condenser is the highest.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] AIR CORE IN PRESSURE SWIRL ATOMIZING NOZZLES
    Som, S. K.
    ATOMIZATION AND SPRAYS, 2012, 22 (04) : 283 - 303
  • [2] Numerical Simulation on Atomizing Performance of Pressure Swirl Nozzles in Ethoxylation Reactors
    Shi, Zhongjing
    Wang, Xuesheng
    Chen, Qinzhu
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2018, 16 (02)
  • [3] Experimental study on spray characteristics of pressure-swirl nozzles in pressurizer
    Lan, Zhike
    Zhu, Dahuan
    Tian, Wenxi
    Su, Guanghui
    Qiu, Suizheng
    ANNALS OF NUCLEAR ENERGY, 2014, 63 : 215 - 227
  • [4] Experimental Study on Atomizing and Reaction Performance of Pressure Swirl Nozzles in Ethoxylation Reactor
    Shi, Zhongjing
    Wang, Xuesheng
    Chen, Qinzhu
    Xiong, Yuanyuan
    Chen, Shuo
    Meng, Xiangyu
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2016, 14 (05) : 965 - 974
  • [5] Application of jet type air cooling condenser in Fengzhen Power Plant
    Ni, Y.Z.
    Zhongguo Dianli/Electric Power, 2001, 34 (11):
  • [6] Experimental and Numerical Study on Inlet Pressure and Reynolds Number in Tangential Input Pressure-Swirl Atomizer
    Aminjan, Kiumars Khani
    Ganji, Davood Domiri
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2025,
  • [7] Numerical simulation of direct air cooling units' condenser added lower windbreak
    Zhou, Lan-Xin
    Li, Jian-Bo
    Li, Wei-Hua
    Tian, Ya-Zhao
    Dongli Gongcheng/Power Engineering, 2008, 28 (05): : 744 - 747
  • [8] NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER OF A DIRECT AIR-COOLED CONDENSER CELL IN A POWER PLANT
    Wen, Juan
    Tang, Dawei
    Wang, Zhicheng
    Zhang, Jing
    Li, Yanjun
    Sun, Fangyuan
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 1, 2014,
  • [9] NUMERICAL RESEARCH ON A DIRECT AIR-COOLED CONDENSER WITH A FLOCCULE-PROOF SCREEN IN A POWER PLANT
    Zhang Wei
    Shi Lei
    Du Xiaoze
    Yang Yongping
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2015, 33 (04) : 262 - 270
  • [10] Numerical study of a power plant condenser tube arrangement
    Zeng, Hui
    Meng, Ji'an
    Li, Zhixin
    APPLIED THERMAL ENGINEERING, 2012, 40 : 294 - 303