Real-time germanium-doped optical fibers for clinical computed tomography dosimetry

被引:2
|
作者
Sarhan, H. G. [1 ]
Saini, S. M. [1 ]
Bahari, N. M. [1 ,2 ]
Bradley, D. A. [3 ,4 ]
Zubair, H. T. [5 ,6 ]
Basaif, A. [5 ]
Oresegun, A. A. [5 ]
Rashid, H. A. Abdul [5 ]
Noor, N. M. [1 ,2 ]
机构
[1] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Radiol, Med Phys Lab, Serdang 43400, Selangor, Malaysia
[2] Univ Putra Malaysia, Hosp Abdul Aziz Shah, Med Phys Unit, Serdang 43400, Selangor, Malaysia
[3] Univ Surrey, Sch Math & Phys, Guildford GU2 7XH, England
[4] Sunway Univ, Ctr Appl Phys & Radiat Technol, Petaling Jaya 46150, Malaysia
[5] Multimedia Univ, Fac Engn, Fibre Opt Res Ctr, Cyberjaya 63100, Malaysia
[6] Lumisyns Technol Sdn Bhd, Cyberjaya 63100, Malaysia
关键词
Computed Tomography; Fabricated Ge-doped silica Fiber; LS-2000; Radioluminescence; Real-time optical fiber dosimetry; GE;
D O I
10.1016/j.radphyschem.2023.110972
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In studies focusing on the practice of clinical computed tomography (CT) a particular concern has been that of delivering unnecessary dose to patients and with it the added risk for radiation-induced cancers. For a CT system, present work has investigated the dosimetric characteristics of a Ge-doped optical fiber real-time dosimetry system (model LS-2000, Lumisyns), measuring beam quality, exposure linearity and exposure duration accuracy. For comparison, the study has used a RaySafe X2 test device (Unfors RaySafe) and a Black Piranha (RTI) QA meter. Irradiations were made using a Somatom Definition Flash dual-source 128-slice CT scanner (Siemens Healthcare). The LS-2000, RaySafe X2, and Black Piranha sensors were exposed to beams energized at accel-erating potentials ranging from 80 to 140 kVp, with tube current-time products from 50 to 300 mA, and exposure durations from 750 to 2000 ms. Constant signal responses from the LS-2000 have been obtained, measured in respect of beam quality, exposure linearity, and time accuracy. In respect of accuracy of beam quality, the RaySafe X2 and Black Piranha maximum deviations were 1% and 5%, respectively; the coefficients of linearity of RaySafe, Black Piranha and LS-2000 are 1%, 0.4% and 1.4%, respectively; the maximum deviation for the time accuracy test for the three sensors are 0.5%, 2% and 1.3%, respectively. Evaluation of the LS-2000 real-time dosimetry system with a Ge-doped optical fiber scintillator points to potential for its use in clinical CT dosimetry.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Germanium-doped optical fiber for real-time radiation dosimetry
    Rahman, A. K. M. Mizanur
    Zubair, H. T.
    Begum, Mahfuza
    Abdul-Rashid, H. A.
    Yusoff, Z.
    Ung, N. M.
    Mat-Sharif, K. A.
    Abdullah, W. S. Wan
    Mahdiraji, Ghafour Amouzad
    Amin, Y. M.
    Maah, M. J.
    Bradley, D. A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 170 - 175
  • [2] Fabricated germanium-doped fibres for computed tomography dosimetry
    Rais, N. N. M.
    Bradley, D. A.
    Hashim, A.
    Osman, N. D.
    Noor, N. M.
    [J]. APPLIED RADIATION AND ISOTOPES, 2019, 153
  • [3] Fabricated germanium-doped optical fibres for computed tomography dosimetry: Glow curve characteristics
    Rais, N. N. M.
    Bradley, D. A.
    Hashim, A.
    Isa, N. M.
    Osman, N. D.
    Ismail, I.
    Hassan, H. A.
    Noor, N. M.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 178
  • [4] MATERIAL STRUCTURE OF GERMANIUM-DOPED OPTICAL FIBERS AND PREFORMS
    PRESBY, HM
    STANDLEY, RD
    MACCHESNEY, JB
    OCONNOR, PB
    [J]. BELL SYSTEM TECHNICAL JOURNAL, 1975, 54 (10): : 1681 - 1692
  • [5] Real-time computed optical interferometric tomography
    Shemonski, Nathan D.
    Liu, Yuan-Zhi
    Ahmad, Adeel
    Adie, Steven G.
    Carney, P. Scott
    Boppart, Stephen A.
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [6] SIMULTANEOUS OBSERVATION OF PHOTOBLEACHING AND PHOTOREFRACTIVE EFFECTS IN GERMANIUM-DOPED OPTICAL FIBERS
    KANELLOPOULOS, SE
    HANDEREK, VA
    JAMSHIDI, H
    ROGERS, AJ
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 1991, 3 (03) : 244 - 246
  • [7] Bragg gratings in defect-free germanium-doped optical fibers
    Albert, J
    Hill, KO
    Johnson, DC
    Bilodeau, F
    Mihailov, SJ
    Borrelli, NF
    Amin, J
    [J]. OPTICS LETTERS, 1999, 24 (18) : 1266 - 1268
  • [8] Real-time dosimetry in radiotherapy using tailored optical fibers
    Rahman, A. K. M. Mizanur
    Zubair, H. T.
    Begum, Mahfuza
    Abdul-Rashid, H. A.
    Yusoff, Z.
    Omar, Nasr Y. M.
    Ung, N. M.
    Mat-Sharif, K. A.
    Bradley, D. A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2016, 122 : 43 - 47
  • [9] Real-time in vivo computed optical interferometric tomography
    Ahmad, Adeel
    Shemonski, Nathan D.
    Adie, Steven G.
    Kim, Hee-Seok
    Hwu, Wen-Mei W.
    Carney, P. Scott
    Boppart, Stephen A.
    [J]. NATURE PHOTONICS, 2013, 7 (06) : 445 - 449
  • [10] Real-time in vivo computed optical interferometric tomography
    Ahmad A.
    Shemonski N.D.
    Adie S.G.
    Kim H.-S.
    Hwu W.-M.W.
    Carney P.S.
    Boppart S.A.
    [J]. Nature Photonics, 2013, 7 (6) : 444 - 448