Research on optimization strategy of harmonic suppression and reactive power compensation of photovoltaic multifunctional grid connected inverter

被引:8
|
作者
Guo, Wang [1 ]
Xu, Wu
机构
[1] Lanzhou Jiaotong Univ, Sch Automat & Elect Engn, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Photovoltaic power generation system; PVMFGCI; Optimization model; Adaptive ant colony algorithm; Power quality; QUALITY IMPROVEMENT; OPERATION; VOLTAGE;
D O I
10.1016/j.ijepes.2022.108649
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a new harmonic suppression and reactive power compensation strategy based on photovoltaic multi-functional grid connected inverter (PVMFGCI) and a three-layer optimization model based on adaptive ant colony algorithm are proposed for optimal control of power quality of grid connected photovoltaic (PV) power generation system. Here, an improved CPT (Conservative Power Theory) current detection method is used to extract harmonic and reactive current components from the load current, and a new PVMFGCI hierarchical optimization model is developed to optimize the power quality at the common connection point (CCP). The proposed three-layer optimization model is an improved form of the two-layer optimization model, which successfully solves the contradiction between the active power grid connection of the PV grid connected inverter and the power quality control. The main objective of the proposed three-layer optimization model is to meet the requirements of active power output of PV power generation, and at the same time, to utilize the remaining capacity of the inverter to control harmonics and compensate reactive power. However, when the remaining capacity of PVMFGCI is sufficient, PVMFGCI can reasonably allocate the remaining capacity through the three -layer optimization model to meet the optimal power quality at the CCP. In this process, the power quality of the microgrid is improved. PVMFGCI provides reactive power compensation, harmonic control and other power quality problems. In addition, when the remaining capacity of PVMFGCI is insufficient, it only needs to maximize the active power and make the harmonic distortion rate and power factor meet the grid connection requirements, which improves the utilization rate of PVMFGCI. The proposed techniques are modeled and the IEEE 33 bus systems are analyzed and their performances are verified experimentally on a developed prototype, in PV output active power variation condition, imbalance loading condition for linear/nonlinear loads, where it has shown a very good performance. The effect of harmonic control and reactive power compensation at each node of the system is obvious.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Harmonic and Reactive Power Compensation of Grid Connected Photovoltaic System
    Renukadevi, V
    Jayanand, B.
    SMART GRID TECHNOLOGIES (ICSGT- 2015), 2015, 21 : 438 - 442
  • [2] Control Strategy for Photovoltaic Grid-connected Inverter with Harmonic Suppression
    Ouyang, Sen
    Ke, Qingpai
    Ma, Wenjie
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 397 - 401
  • [3] Research on Harmonic Suppression Strategy of Photovoltaic Grid-connected Inverter Based on Grid Voltage Control
    Bu, Yingchun
    Lu, Guangping
    Zhang, Lanhong
    Zhou, Yunlong
    NONLINEAR OPTICS QUANTUM OPTICS-CONCEPTS IN MODERN OPTICS, 2018, 48 (04): : 333 - 343
  • [4] Single-phase Grid Integrated Photovoltaic Inverter for Harmonic and Reactive Power Compensation
    Behera, Maheswar Prasad
    Ray, Pravat Kumar
    2015 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2015,
  • [5] Research on Harmonic Suppression Strategy of Grid Connected Inverter under Multi-Harmonic Sources
    Yang Q.
    Liang Y.
    Wei J.
    Liu Y.
    Yuan Z.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (11): : 2908 - 2920
  • [6] Photovoltaic Grid-connected Inverter Harmonic Compensation and Grid-connected Unified Control
    Xu Jin
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 696 - 699
  • [7] Research on the strategy of cooperative control between photovoltaic grid-connected and reactive power compensation technology
    Li, Zhigang
    Peng, Yalan
    Yao, Fang
    Liu, Mingyu
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2278 - 2283
  • [8] Limited Active Harmonic Compensation in a Grid-Connected Photovoltaic Inverter
    Platakis, Andrius
    Baskys, Algirdas
    Paulauskas, Nerijus
    2013 NORCHIP, 2013,
  • [9] Hybrid Control Strategy of Grid-tied Inverter for Harmonic and Reactive Power Compensation
    Wang, Qi
    Qin, Wenping
    Han, Xiaoqing
    Wang, Peng
    Wang, Lei
    Zhou, Yixiong
    Ren, Chunguang
    PROCEEDINGS OF THE 2018 13TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2018), 2018, : 249 - 253
  • [10] The control strategy of Harmonic suppression of Photovoltaic grid-connected inverter based on PI plus MPR
    Zhou, Xiandong
    Huang, Peng
    Yu, Weigang
    Feng, Yebing
    Qian, Ziqiang
    Yang, Peihao
    2019 4TH IEEE WORKSHOP ON THE ELECTRONIC GRID (EGRID), 2019, : 148 - 152