Numerical simulation-based assessment of pH-sensitive chemical exchange saturation transfer MRI quantification accuracy across field strengths

被引:6
|
作者
Sun, Phillip Zhe [1 ,2 ,3 ]
机构
[1] Emory Univ, Primate Imaging Ctr, Emory Natl Primate Res Ctr, Atlanta, GA USA
[2] Emory Univ, Dept Radiol & Imaging Sci, Sch Med, Atlanta, GA USA
[3] Emory Univ, Dept Radiol & Imaging Sci, Sch Med, 954 Gatewood Rd North East, Atlanta, GA 30329 USA
关键词
amide proton transfer; Bloch-McConnell equations; chemical exchange saturation transfer; quasi-steady-state analysis; PULSED CEST-MRI; MAGNETIZATION-TRANSFER; QUANTITATIVE DESCRIPTION; RADIATION NECROSIS; WEIGHTED MRI; T; AMIDE; RELAXATION; OPTIMIZATION; TISSUE;
D O I
10.1002/nbm.5000
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Chemical exchange saturation transfer (CEST) MRI detects dilute labile protons via their exchange with bulk water, conferring pH sensitivity. Based on published exchange and relaxation properties, a 19-pool simulation was used to model the brain pH-dependent CEST effect and assess the accuracy of quantitative CEST (qCEST) analysis across magnetic field strengths under typical scan conditions. First, the optimal B-1 amplitude was determined by maximizing pH-sensitive amide proton transfer (APT) contrast under the equilibrium condition. Apparent and quasi-steady-state (QUASS) CEST effects were then derived under the optimal B-1 amplitude as functions of pH, RF saturation duration, relaxation delay, Ernst flip angle, and field strength. Finally, CEST effects, particularly the APT signal, were isolated with spinlock model-based Z-spectral fitting to evaluate the accuracy and consistency of CEST quantification. Our data showed that QUASS reconstruction significantly improved the consistency between simulated and equilibrium Z-spectra. The residual difference between QUASS and equilibrium CEST Z-spectra was, on average, 30 times less than that of the apparent CEST Z-spectra across field strengths, saturation, and repetition times. Also, the spinlock fitting of the QUASS CEST effect significantly reduced the residual errors 9-fold. Furthermore, the isolated APT amplitude from QUASS reconstruction was consistent and higher than the apparent CEST analysis under nonequilibrium conditions. To summarize, this study confirmed that QUASS reconstruction facilitates accurate determination of the CEST system under different scan protocols across field strengths, with the potential to help standardize CEST quantification.
引用
收藏
页数:12
相关论文
共 13 条
  • [1] Paramagnetic lanthanide(III) complexes as pH-sensitive chemical exchange saturation transfer (CEST) contrast agents for MRI applications
    Aime, S
    Barge, A
    Delli Castelli, D
    Fedeli, F
    Mortillaro, A
    Nielsen, FU
    Terreno, E
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) : 639 - 648
  • [2] A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging
    Kim, Jinsuh
    Wu, Yin
    Guo, Yingkun
    Zheng, Hairong
    Sun, Phillip Zhe
    CONTRAST MEDIA & MOLECULAR IMAGING, 2015, 10 (03) : 163 - 178
  • [3] Boosting quantification accuracy of chemical exchange saturation transfer MRI with a spatial-spectral redundancy-based denoising method
    Chen, Xinran
    Wu, Jian
    Yang, Yu
    Chen, Huan
    Zhou, Yang
    Lin, Liangjie
    Wei, Zhiliang
    Xu, Jiadi
    Chen, Zhong
    Chen, Lin
    NMR IN BIOMEDICINE, 2023, 37 (01)
  • [4] Boosting quantification accuracy of chemical exchange saturation transfer MRI with a spatial-spectral redundancy-based denoising method
    Chen, Xinran
    Wu, Jian
    Yang, Yu
    Chen, Huan
    Zhou, Yang
    Lin, Liangjie
    Wei, Zhiliang
    Xu, Jiadi
    Chen, Zhong
    Chen, Lin
    NMR IN BIOMEDICINE, 2023,
  • [5] Determination of an optimally sensitive and specific chemical exchange saturation transfer MRI quantification metric in relevant biological phantoms
    Ray, Kevin J.
    Larkin, James R.
    Tee, Yee K.
    Khrapitchev, Alexandre A.
    Karunanithy, Gogulan
    Barber, Michael
    Baldwin, Andrew J.
    Chappell, Michael A.
    Sibson, Nicola R.
    NMR IN BIOMEDICINE, 2016, 29 (11) : 1624 - 1633
  • [6] Correction for artifacts induced by B0 and B1 field inhomogeneities in pH-Sensitive chemical exchange saturation transfer (CEST) Imaging
    Sun, Phillip Zhe
    Farrar, Christian T.
    Sorensen, A. Gregory
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1207 - 1215
  • [7] In vivo pH mapping with omega plot-based quantitative chemical exchange saturation transfer MRI
    Ji, Yang
    Lu, Dongshuang
    Sun, Phillip Zhe
    Zhou, Iris Y.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 299 - 307
  • [8] Chemical Exchange Saturation Transfer MRI: Sensitive to Intracellular PH Change Over Time in a Rat Model of Brain Cancer
    Mozaffari, M.
    Nystrom, N.
    Li, A.
    Bellyou, M.
    Scholl, T.
    Bartha, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E519 - E519
  • [9] Analysis of chemical exchange saturation transfer contributions from brain metabolites to the Z-spectra at various field strengths and pH
    Vitaliy Khlebnikov
    Wybe J. M. van der Kemp
    Hans Hoogduin
    Dennis W. J. Klomp
    Jeanine J. Prompers
    Scientific Reports, 9
  • [10] Analysis of chemical exchange saturation transfer contributions from brain metabolites to the Z-spectra at various field strengths and pH
    Khlebnikov, Vitaliy
    van der Kemp, Wybe J. M.
    Hoogduin, Hans
    Klomp, Dennis W. J.
    Prompers, Jeanine J.
    SCIENTIFIC REPORTS, 2019, 9 (1)