Dosimetric Comparison of Postmastectomy Radiotherapy Plans for Synchronous Bilateral Breast Cancer, Including Regional Lymph Node Irradiation

被引:0
|
作者
Wu, Xiuxiu [1 ,2 ]
Huang, Jianghua [1 ,2 ]
Lin, Xiao [1 ,3 ]
Zhang, Xingxing [1 ,2 ]
Lu, Huangping [1 ,2 ]
Sun, Wei [1 ,2 ]
Duan, Song [1 ,2 ]
Shi, Juntian [1 ,2 ]
Huang, Xiaobo [1 ,3 ]
机构
[1] Sun Yat Sen Univ, Sun Yat Sen Mem Hosp, Med Res Ctr, Guangdong Prov Key Lab Malignant Tumor Epigenet &, Guangzhou 510120, Peoples R China
[2] Sun Yat Sen Univ, Sun Yat Sen Mem Hosp, Dept Radiat Oncol, Guangzhou 510120, Peoples R China
[3] Sun Yat Sen Univ, Sun Yat Sen Mem Hosp, Dept Breast Tumor Ctr, Guangzhou 510120, Peoples R China
关键词
synchronous bilateral breast cancer; postmastectomy radiotherapy; regional lymph node; dosimetric comparison; intensity-modulated radiation therapy; volumetric-modulated arc therapy;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background To investigate the optimal radiotherapy plans for synchronous bilateral breast cancer (SBBC) patients receiving postmastectomy radiotherapy (PMRT), including regional lymph node irradiation (RNI). Methods For 10 SBBC patients who underwent bilateral mastectomy and received bilateral PMRT with RNI, 3 integrally optimized plans with a single isocenter were designed for each patient in this retrospective study: intensity-modulated radiation therapy (IMRT) with 9 fixed beams (9F-IMRT), volumetric-modulated arc therapy (VMAT) with 2 pairs of half arcs (2F-VMAT), VMAT with 2 pairs of outer tangential arcs and 1 pair of 200-degree arcs (3F-VMAT). The paired t-test (in the case of normal variables) and Friedman's test (in the case of nonnormal variables) were applied to compare the planning target volumes (PTVs) and organs at risk (OARs) values of the 3 techniques. Results The 3 techniques provided adequate target dose coverage and comparable results for PTVs. For OARs, 3F-VMAT yielded the lowest mean or median values of the left lung (15.02 +/- 1.57 Gy) and right lung (14.91 +/- 1.14 Gy), heart (6.19 (1.96) Gy), coronary artery (15.96 +/- 5.76 Gy) and liver (8.10 +/- 2.70 Gy) which were significantly different from those of 9F-IMRT and 2F-VMAT. The percentages of volume at various doses (V-5, V-10, V-20, and V-30) of 3F-VMAT plans were also lower than or comparable with those of 9F-IMRT and 2F-VMAT. The monitor units (MUs) of 3F-VMAT were 31% higher than those of 9F-IMRT and comparable with those of 2F-VMAT; however, there were time savings and halved beam-on times (BOTs) compared to 9F-IMRT. Conclusions The 3F-VMAT plan yielded comparable target coverage compared with 9F-IMRT and 2F-VMAT, was superior in dose sparing of normal tissues and enabled shorter BOTs, improving treatment efficiency. In our research, 3F-VMAT was the optimal radiotherapy technique for SBBC patients receiving PMRT including RNI.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dosimetric Comparison of Postmastectomy Radiotherapy Plans for Synchronous Bilateral Breast Cancer, Including Regional Lymph Node Irradiation
    Wu, Xiuxiu
    Huang, Jianghua
    Lin, Xiao
    Zhang, Xingxing
    Lu, Huangping
    Sun, Wei
    Duan, Song
    Shi, Juntian
    Huang, Xiaobo
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2023, 22
  • [2] Evaluation of optimal treatment planning for radiotherapy of synchronous bilateral breast cancer including regional lymph node irradiation
    Cho, Yeona
    Cho, Yoon Jin
    Chang, Won Suk
    Kim, Jun Won
    Choi, Won Hoon
    Lee, Ik Jae
    [J]. RADIATION ONCOLOGY, 2019, 14 (1)
  • [3] Evaluation of optimal treatment planning for radiotherapy of synchronous bilateral breast cancer including regional lymph node irradiation
    Yeona Cho
    Yoon Jin Cho
    Won Suk Chang
    Jun Won Kim
    Won Hoon Choi
    Ik Jae Lee
    [J]. Radiation Oncology, 14
  • [4] Dosimetric comparison of techniques for left-sided breast and regional lymph node radiotherapy
    Joslin-Tan, T.
    Maggs, R.
    Pembroke, C.
    Lambert, J.
    O'Neill, K.
    Staffurth, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1005 - S1005
  • [5] Evaluation of fixed-jaw IMRT and tangential partial-VMAT radiotherapy plans for synchronous bilateral breast cancer irradiation based on a dosimetric study
    Huang, Jiang-Hua
    Wu, Xiu-Xiu
    Lin, Xiao
    Shi, Jun-Tian
    Ma, Yu-Jia
    Duan, Song
    Huang, Xiao-Bo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09): : 31 - 41
  • [6] Synchronous bilateral breast cancer patients treated with hypofractionated bilateral breast irradiation: A dosimetric and clinical study
    Narasimhulu, B. C.
    Valiyaveettil, Deepthi
    Joseph, Deepa
    Ahmed, Syed Fayaz
    Vijayakrishna, E.
    Malik, Monica
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2020, 16 (06) : 1309 - 1313
  • [7] Technical approaches to regional lymph node irradiation for breast cancer
    Kirby, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S7 - S7
  • [8] Cardiopulmonary Protection for Bilateral Breast Irradiation: A Dosimetric Comparison between Proton and Photon Plans
    Liu, C. S.
    Chen, T. H.
    Wang, R. Y.
    Lee, H. L.
    Chiou, J. F.
    Lu, L. S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E688 - E689
  • [9] Evaluation of the dosimetric and radiobiological parameters in four radiotherapy regimens for synchronous bilateral breast cancer
    Kang, Sang-Won
    Kang, Seonghee
    Lee, Boram
    Song, Changhoon
    Eom, Keun-Yong
    Jang, Bum-Sup
    Kim, In Ah
    Kim, Jae-Sung
    Cho, Woong
    Shin, Dong-Suk
    Kim, Jin-Young
    Chung, Jin-Beom
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (08):
  • [10] Use of tomotherapy in treatment of synchronous bilateral breast cancer: dosimetric comparison study
    Wadasadawala, T.
    Visariya, B.
    Sarin, R.
    Upreti, R. R.
    Paul, S.
    Phurailatpam, R.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1048):