Association for Academic Surgery Evaluating the Utility of High Sensitivity Troponin in Blunt Cardiac Injury

被引:5
|
作者
Nathwani, Jay N. [1 ,3 ]
Baucom, Matthew R. [1 ]
Salvator, Ann [1 ]
Makley, Amy T. [1 ]
Tsuei, Betty J. [1 ]
Droege, Christopher A. [2 ]
Goodman, Michael D. [1 ]
Nomellini, Vanessa [1 ]
机构
[1] Univ Cincinnati, Dept Surg, Cincinnati, OH USA
[2] Univ Cincinnati, Dept Pharm Serv, Cincinnati, OH USA
[3] Univ Cincinnati, Dept Surg, 231 Albert Sabin WayML 0558, Cincinnati, OH 45267 USA
关键词
Available online xxx; Blunt cardiac injury; High sensitivity troponin; Sternal fracture; MYOCARDIAL CONTUSION; TRAUMA; ELEVATION;
D O I
10.1016/j.jss.2022.08.030
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Screening for blunt cardiac injury (BCI) includes obtaining a serum troponin level and an electrocardiogram for patients diagnosed with a sternal fracture. Our institution has transitioned to the use of a high sensitivity troponin I (hsTnI). The aim of this study was to determine whether hsTnI is comparable to troponin I (TnI) in identifying clinically significant BCI. Materials and methods: Trauma patients presenting to a level I trauma center over a 24-mo period with the diagnosis of sternal fracture were screened for BCI. Any initial TnI more than 0.04 ng/mL or hsTnI more than 18 ng/L was considered positive for potential BCI. Clinically significant BCI was defined as a new-bundle branch block, ST wave change, echocardiogram change, or need for cardiac catheterization. Results: Two hundred sixty five patients with a sternal fracture were identified, 161 underwent screening with TnI and 104 with hsTnI. For TnI, the sensitivity and specificity for detection of clinically significant BCI was 0.80 and 0.79, respectively. For hsTnI, the sensitivity and specificity for detection of clinically significant BCI was 0.71 and 0.69, respectively. A multivariate analysis demonstrated the odds ratio for significant BCI with a positive TnI was 14.4 (95% confidence interval, 3.9-55.8, P < 0.0001) versus an odds ratio of 5.48 (95% confidence interval 1.9-15.7, P = 0.002) in the hsTnI group. Conclusions: The sensitivity of hsTnI is comparable to TnI for detection of significant BCI. Additional investigation is needed to determine the necessity and interval for repeat testing and the need for additional diagnostic testing.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 50 条
  • [1] Re-Evaluating the Use of High Sensitivity Troponin to Diagnose Blunt Cardiac Injury
    Becker, Ellen R.
    Price, Adam D.
    Whitrock, Jenna N.
    Smith, Maia
    Baucom, Matthew R.
    Makley, Amy T.
    Goodman, Michael D.
    JOURNAL OF SURGICAL RESEARCH, 2024, 300 : 150 - 156
  • [2] Diagnostic significance of high sensitivity troponin in diagnosis of blunt cardiac injury
    Pfortmueller, Carmen Andrea
    Lindner, Gregor
    Leichtle, Alexander Benedikt
    Fiedler, Georg Martin
    Exadaktylos, Aristomenis Konstantinos
    INTENSIVE CARE MEDICINE, 2014, 40 (04) : 623 - 624
  • [3] Diagnostic significance of high sensitivity troponin in diagnosis of blunt cardiac injury
    Carmen Andrea Pfortmueller
    Gregor Lindner
    Alexander Benedikt Leichtle
    Georg Martin Fiedler
    Aristomenis Konstantinos Exadaktylos
    Intensive Care Medicine, 2014, 40 : 623 - 624
  • [4] High-Sensitivity Troponin in Non-Cardiac Surgery
    Ozkan, Can
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2024, 121 (07)
  • [5] Utility of cardiac troponin measurement after cardiac surgery
    Dehoux, M
    Provenchère, S
    Benessiano, J
    Lasocki, S
    Lecharny, JB
    Bronchard, R
    Dilly, MP
    Philip, I
    CLINICA CHIMICA ACTA, 2001, 311 (01) : 41 - 44
  • [6] High-Sensitivity Cardiac Troponin I Thresholds to Identify Myocardial Injury After Noncardiac Surgery
    Amjad, Maryam
    CANADIAN JOURNAL OF CARDIOLOGY, 2024, 40 (04) : 734 - 734
  • [7] Acute kidney injury induces high-sensitivity troponin measurement changes after cardiac surgery
    Omar, Amr S.
    Mahmoud, Khaled
    Hanoura, Samy
    Osman, Hany
    Sivadasan, Praveen
    Sudarsanan, Suraj
    Shouman, Yasser
    Singh, Rajvir
    AlKhulaifi, Abdulaziz
    BMC ANESTHESIOLOGY, 2017, 17
  • [8] Acute kidney injury induces high-sensitivity troponin measurement changes after cardiac surgery
    Amr S Omar
    Khaled Mahmoud
    Samy Hanoura
    Hany Osman
    Praveen Sivadasan
    Suraj Sudarsanan
    Yasser Shouman
    Rajvir Singh
    Abdulaziz AlKhulaifi
    BMC Anesthesiology, 17
  • [9] The utility of risk scores when evaluating for acute myocardial infarction using high-sensitivity cardiac troponin I
    Gibbs, Joseph
    DeFilippi, Christopher
    Peacock, Frank
    Mahler, Simon
    Nowak, Richard
    Christenson, Robert
    Apple, Fred
    Jacobsen, Gordon
    McCord, James
    AMERICAN HEART JOURNAL, 2020, 227 : 1 - 8
  • [10] Utility of High Sensitivity Troponin I to Monitor Cardiac Allograft Vasculopathy Progression
    Patel, K.
    DeStefano, R.
    Yadalam, A.
    Beshiri, A.
    Almuwaqqat, Z.
    Desai, S.
    Book, W.
    Quyyumi, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S316 - S316