Applications of deep learning to reduce the need for iodinated contrast media for CT imaging: a systematic review

被引:9
|
作者
Azarfar, Ghazal [1 ,2 ]
Ko, Seok-Bum [2 ]
Adams, Scott J. [3 ]
Babyn, Paul S. [1 ]
机构
[1] Univ Saskatchewan, Dept Med Imaging, Saskatoon, SK, Canada
[2] Univ Saskatchewan, Dept Elect & Comp Engn, Saskatoon, SK, Canada
[3] Stanford Univ, Dept Radiol, Stanford, CA USA
关键词
Computed tomography; Iodinated contrast media reduction; Contrast enhancement; Deep learning; PEDIATRIC CT; RECONSTRUCTION;
D O I
10.1007/s11548-023-02862-w
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeThe usage of iodinated contrast media (ICM) can improve the sensitivity and specificity of computed tomography (CT) for many clinical indications. However, the adverse effects of ICM administration can include renal injury, life-threatening allergic-like reactions, and environmental contamination. Deep learning (DL) models can generate full-dose ICM CT images from non-contrast or low-dose ICM administration or generate non-contrast CT from full-dose ICM CT. Eliminating the need for both contrast-enhanced and non-enhanced imaging or reducing the amount of required contrast while maintaining diagnostic capability may reduce overall patient risk, improve efficiency and minimize costs. We reviewed the current capabilities of DL to reduce the need for contrast administration in CT.MethodsWe conducted a systematic review of articles utilizing DL to reduce the amount of ICM required in CT, searching MEDLINE, Embase, Compendex, Inspec, and Scopus to identify papers published from 2016 to 2022. We classified the articles based on the DL model and ICM reduction.ResultsEighteen papers met the inclusion criteria for analysis. Of these, ten generated synthetic full-dose (100%) ICM from real non-contrast CT, while four augmented low-dose to full-dose ICM CT. Three used DL to create synthetic non-contrast CT from real 100% ICM CT, while one paper used DL to translate the 100% ICM to non-contrast CT and vice versa. DL models commonly used generative adversarial networks trained and tested by paired contrast-enhanced and non-contrast or low ICM CTs. Image quality metrics such as peak signal-to-noise ratio and structural similarity index were frequently used for comparing synthetic versus real CT image quality.ConclusionDL-generated contrast-enhanced or non-contrast CT may assist in diagnosis and radiation therapy planning; however, further work to optimize protocols to reduce or eliminate ICM for specific pathology is still needed along with a dedicated assessment of the clinical utility of these synthetic images.
引用
收藏
页码:1903 / 1914
页数:12
相关论文
共 50 条
  • [1] Applications of deep learning to reduce the need for iodinated contrast media for CT imaging: a systematic review
    Ghazal Azarfar
    Seok-Bum Ko
    Scott J. Adams
    Paul S. Babyn
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 1903 - 1914
  • [2] Organic Nanoplatforms for Iodinated Contrast Media in CT Imaging
    Zhang, Peng
    Ma, Xinyu
    Guo, Ruiwei
    Ye, Zhanpeng
    Fu, Han
    Fu, Naikuan
    Guo, Zhigang
    Zhang, Jianhua
    Zhang, Jing
    [J]. MOLECULES, 2021, 26 (23):
  • [3] Using deep learning techniques in medical imaging: a systematic review of applications on CT and PET
    Domingues, Ines
    Pereira, Gisele
    Martins, Pedro
    Duarte, Hugo
    Santos, Joao
    Abreu, Pedro Henriques
    [J]. ARTIFICIAL INTELLIGENCE REVIEW, 2020, 53 (06) : 4093 - 4160
  • [4] Using deep learning techniques in medical imaging: a systematic review of applications on CT and PET
    Inês Domingues
    Gisèle Pereira
    Pedro Martins
    Hugo Duarte
    João Santos
    Pedro Henriques Abreu
    [J]. Artificial Intelligence Review, 2020, 53 : 4093 - 4160
  • [5] Iodinated blood pool contrast media for preclinical X-ray imaging applications - A review
    Hallouard, Francois
    Anton, Nicolas
    Choquet, Philippe
    Constantinesco, Andre
    Vandamme, Thierry
    [J]. BIOMATERIALS, 2010, 31 (24) : 6249 - 6268
  • [6] The prevention of anaphylactoid reactions to iodinated radiological contrast media: A systematic review
    Delaney A.
    Carter A.
    Fisher M.
    [J]. BMC Medical Imaging, 6 (1)
  • [7] Hypothyroidism in neonates post-iodinated contrast media: a systematic review
    Ahmet, Alexandra
    Lawson, Margaret L.
    Babyn, Paul
    Tricco, Andrea C.
    [J]. ACTA PAEDIATRICA, 2009, 98 (10) : 1568 - 1574
  • [8] Oncologic Applications of Artificial Intelligence and Deep Learning Methods in CT Spine Imaging-A Systematic Review
    Ong, Wilson
    Lee, Aric
    Tan, Wei Chuan
    Fong, Kuan Ting Dominic
    Lai, Daoyong David
    Tan, Yi Liang
    Low, Xi Zhen
    Ge, Shuliang
    Makmur, Andrew
    Ong, Shao Jin
    Ting, Yong Han
    Tan, Jiong Hao
    Kumar, Naresh
    Hallinan, James Thomas Patrick Decourcy
    [J]. CANCERS, 2024, 16 (17)
  • [9] Shortage of iodinated contrast media: Status and possible chances-A systematic review
    Koeppel, David R.
    Boehm, Ingrid B.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2023, 164
  • [10] Functional imaging of tumors using CT and iodinated contrast media of different molecular weights
    Clément, O
    Robert, P
    Cuénod, CA
    Siauve, N
    Sobotka, A
    Kahn, E
    Frija, G
    [J]. ACADEMIC RADIOLOGY, 2002, 9 : S212 - S214