Myocardial creep and cardiorespiratory motion correction improves diagnostic accuracy of Rubidium-82 cardiac positron emission tomography

被引:1
|
作者
Lassen, Martin Lyngby [1 ,2 ]
Rasmussen, Thomas [1 ,2 ]
Byrne, Christina [1 ,2 ]
Holmvang, Lene [3 ]
Kjaer, Andreas [1 ,2 ]
Hasbak, Philip [1 ]
机构
[1] Rigshosp, Univ Hosp Copenhagen, Dept Clin Physiol Nucl Med & PET, Copenhagen, Denmark
[2] Univ Copenhagen, Fac Hlth & Med Sci, Dept Biomed Sci, Cluster Mol Imaging, Copenhagen, Denmark
[3] Rigshosp, Dept Cardiol, Ctr Heart, Copenhagen, Denmark
关键词
Ischemic heart disease; motion correction; cardiac PET; myocardial perfusion imaging; Rubidium-82;
D O I
10.1007/s12350-023-03360-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim. To evaluate the feasibility of retrospectively detecting and correcting periodical (cardiac and respiratory motion) and non-periodical shifts of the myocardial position (myocardial creep) using only the acquired Rubidium-82 positron emission tomography raw (listmode) data. Methods. This study comprised 25 healthy participants (median age = 23 years) who underwent repeat rest/adenosine stress Rubidium-82 myocardial perfusion imaging (MPI) and 53 patients (median age = 64 years) considered for revascularization who underwent a single MPI session. All subjects were evaluated for myocardial creep during MPI by assessing the myocardial position every 200 ms. A proposed motion correction protocol, including corrections for cardiorespiratory and creep motion (3xMC), was compared to a guideline-recommended protocol (StandardRecon). For the volunteers, we report test-retest repeatability using standard error of measurements (SEM). For the patient cohort, we evaluated the area under the receiver operating curve (AUC) for both stress and ischemic total perfusion deficits (sTPD and iTPD, respectively) using myocardial ischemia defined as fractional flow reserve values < 0.8 in the relevant coronary segment as the gold standard. Results. Test-retest repeatability was significantly improved following corrections for myocardial creep (SEM; sTPD: StandardRecon = 2.2, 3xMC = 1.8; iTPD: StandardRecon = 1.6, 3xMC = 1.2). AUC analysis of the ROC curves revealed significant improvements for iTPD measurements following 3xMC [sTPD: StandardRecon = 0.88, 3xMC = 0.92 (P = .21); iTPD: StandardRecon = 0.88, 3xMC = 0.95 (P = .039)]. Conclusion. 3xMC has the potential to improve the diagnostic accuracy of myocardial MPI obtained from positron emission tomography. Therefore, its use should be considered both in clinical routine and large-scale multicenter studies.
引用
收藏
页码:2289 / 2300
页数:12
相关论文
共 50 条
  • [1] Myocardial creep and cardiorespiratory motion correction improves diagnostic accuracy of Rubidium-82 cardiac positron emission tomography
    Martin Lyngby Lassen
    Thomas Rasmussen
    Christina Byrne
    Lene Holmvang
    Andreas Kjaer
    Philip Hasbak
    [J]. Journal of Nuclear Cardiology, 2023, 30 (6) : 2289 - 2300
  • [2] MYOCARDIAL UPTAKE OF RUBIDIUM-82 USING POSITRON EMISSION TOMOGRAPHY
    BUDINGER, TF
    YANO, Y
    DERENZO, SE
    HUESMAN, RH
    CAHOON, JL
    MOYER, BR
    GREENBERG, WL
    OBRIEN, HA
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1979, 20 (06) : 603 - 603
  • [3] Risk Stratification with Cardiac Rubidium-82 Positron Emission Tomography
    Boyden T.F.
    Murthy V.L.
    [J]. Current Cardiovascular Imaging Reports, 2014, 7 (5) : 1 - 10
  • [4] Myocardial perfusion scintigraphy using rubidium-82 positron emission tomography
    Arumugam, Parthiban
    Tout, Deborah
    Tonge, Christine
    [J]. BRITISH MEDICAL BULLETIN, 2013, 107 (01) : 87 - 100
  • [5] DIAGNOSTIC ACCURACY OF QUANTITATIVE RUBIDIUM-82 POSITRON EMISSION TOMOGRAPHY MYOCARDIAL PERFUSION IMAGING: VALIDATION WITH INVASIVE CORONARY ANGIOGRAPHY
    Nakazato, Ryo
    Slomka, Piotr J.
    Hayes, Sean W.
    Cheng, Victor Y.
    Fermin, Jimmy S.
    Thomson, Louise E. J.
    Friedman, John D.
    Germano, Guido
    Berman, Daniel S.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E652 - E652
  • [6] Extracardiac abnormalities on rubidium-82 cardiac positron emission tomography/computed tomography
    Mirpour, Sahar
    Khandani, Amir H.
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (04) : 260 - 264
  • [7] Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease
    Sampson, Uchechukwu K.
    Dorbala, Sharmila
    Limaye, Atul
    Kwong, Raymond
    Di Carli, Marcelo F.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (10) : 1052 - 1058
  • [8] Feasibility of exercise rubidium-82 positron emission tomography myocardial perfusion imaging
    Chow, BJ
    Ruddy, TD
    Dalipaj, MM
    de Kemp, RA
    Nadeau, C
    Ukkonen, H
    Ananthasubramaniam, K
    Beanlands, RS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 428A - 428A
  • [9] Rubidium-82 Cardiac Positron Emission Tomography Imaging An Overview for the General Cardiologist
    Dhar, Ritesh
    Ananthasubramaniam, Karthikeyan
    [J]. CARDIOLOGY IN REVIEW, 2011, 19 (05) : 255 - 263
  • [10] INFARCTION SIZING AND MYOCARDIAL PERFUSION MEASUREMENTS USING RUBIDIUM-82 AND POSITRON EMISSION TOMOGRAPHY
    BUDINGER, TF
    YANO, Y
    DERENZO, SE
    HUESMAN, RH
    YEN, CK
    MOYER, BR
    SHERMAN, LG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02): : 399 - 399