Evaluation of Air Quality inside Self-Contained Breathing Apparatus Used by Firefighters

被引:1
|
作者
Kim, Soo Jin [1 ,2 ]
Ham, Seunghon [3 ]
机构
[1] Seoul Natl Univ, Grad Sch Publ Hlth, Dept Epidemiol, Seoul 03312, South Korea
[2] Seoul Metropolitan Fire & Disaster Headquarters, Seoul 03312, South Korea
[3] Gachon Univ, Coll Med, Gil Med Ctr, Dept Occupat & Environm Med, Incheon 21565, South Korea
来源
FIRE-SWITZERLAND | 2023年 / 6卷 / 09期
基金
新加坡国家研究基金会;
关键词
firefighter; self-contained breathing apparatus (SCBA); air quality; SCBA charging environment; CO; water; FIRE; EXPOSURES; SMOKE; PROTECTION; IMPACTS; COHORT;
D O I
10.3390/fire6090347
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
(1) Background: When a fire breaks out, combustibles are burned and toxic substances such as carbon monoxide (CO), polycyclic aromatic hydrocarbons (PAH), benzene, and hydrogen cyanide are produced. The purpose of this study is to evaluate the air quality inside self-contained breathing apparatus (SCBA) by comparing it to that in the environment where the SCBA charger is installed. (2) Methods: The design of this study was a simulation-based case-control experiment study, and the experiment was conducted at two fire stations located on land and on water. When charging the SCBA, it was differentiated according to the presence or absence of exposure to harmful substances and the degree of exposure. The air quality inside the SCBA in the charging room installed in the fire station garages located on land and in the water, which were not completely isolated from harmful substances, was evaluated. CO, carbon dioxide (CO2), water, and oil mist were measured and analyzed to determine the air quality inside the SCBA. (3) Results: In the case of land firefighting stations, the mean CO among the SCBA internal air quality items was 20 times higher than the outside the SCBA, and higher than the safe range in the group with the highest exposure at the sites of firefighting buildings completely isolated from hazardous substances. The CO levels of all items of water were analyzed to be higher than the safe range in the floating fire station. (4) Conclusions: It was confirmed that the installation environment of an SCBA charging room can affect the safety of the charged internal air quality components. The results of this study can be actively used for the operation and management of SCBA charging room environments when building firefighting buildings in the future for the hygiene, safety, and health of firefighters.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] A biomechanical evaluation of firefighters' musculoskeletal loads when carrying self-contained breathing apparatus in walking and running
    Wang, Shitan
    Feng, Chenglong
    Chen, Xinpeng
    Shan, Mianjia
    Niu, Wenxin
    [J]. JOURNAL OF SAFETY RESEARCH, 2023, 87 : 1 - 14
  • [2] EVALUATION OF FEDERAL MAN TESTS FOR SELF-CONTAINED BREATHING APPARATUS
    BERNARD, TE
    STEIN, RL
    KAMON, E
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1977, 38 (12): : 689 - 695
  • [3] Strain of firefighters with self-contained breathing apparatus. How suitable are suitability tests?
    Heblich, F.
    Sammito, S.
    [J]. ZENTRALBLATT FUR ARBEITSMEDIZIN ARBEITSSCHUTZ UND ERGONOMIE, 2015, 65 (02): : 87 - 91
  • [4] Field evaluation of a new prototype self-contained breathing apparatus
    Coca, Aitor
    Kim, Jung-Hyun
    Duffy, Richard
    Williams, W. Jon
    [J]. ERGONOMICS, 2011, 54 (12) : 1197 - 1206
  • [5] Psychophysiological responses in experienced firefighters undertaking repeated self-contained breathing apparatus tasks
    Young, Paul M.
    Gibson, Alan St Clair
    Partington, Elizabeth
    Partington, Sarah
    Wetherell, Mark A.
    [J]. ERGONOMICS, 2014, 57 (12) : 1898 - 1906
  • [6] Respiratory Responses during Exercise in Self-contained Breathing Apparatus among Firefighters and Nonfirefighters
    Hostler, David
    Pendergast, David R.
    [J]. SAFETY AND HEALTH AT WORK, 2018, 9 (04) : 468 - 472
  • [7] Evaluation of Fitness to Utilize Self-Contained Breathing Apparatus (SCBA)
    Miedinger, David
    Blaeuenstein, Andrea
    Wolf, Nathalie
    Frey, Franz
    Karli, Christoph
    Leuppi, Joerg D.
    [J]. JOURNAL OF ASTHMA, 2010, 47 (02) : 178 - 184
  • [8] PROTECTION FACTORS OF SELF-CONTAINED COMPRESSED-AIR BREATHING APPARATUS
    ADLEY, FE
    UHLE, RJ
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1969, 30 (04): : 355 - +
  • [9] Study of alternative technologies to compressed air self-contained breathing apparatus
    Moore, J.Timothy
    [J]. Space Congress Proceedings, 1999,
  • [10] Oxygen and self-contained oxygen breathing apparatus
    Krokhalev, B.G.
    [J]. Bezopasnost' Truda v Promyshlennosti, 2005, (08): : 37 - 44