The intracavitary ECG method for tip location of ultrasound-guided centrally inserted central catheter in neonates

被引:11
|
作者
D'Andrea, Vito [1 ]
Pezza, Lucilla [1 ]
Prontera, Giorgia [1 ]
Ancora, Gina [2 ]
Pittiruti, Mauro [3 ]
Vento, Giovanni [1 ]
Barone, Giovanni [2 ]
机构
[1] Fdn Policlin Univ Agostino Gemelli IRCCS, Dept Woman & Child Hlth & Publ Hlth, Rome, Italy
[2] Infermi Hosp Rimini, Azienda Sanitaria Romagna, Neonatal Intens Care Unit, Rimini, Italy
[3] Fdn Policlin Univ Agostino Gemelli IRCCS, Dept Surg, Rome, Italy
来源
JOURNAL OF VASCULAR ACCESS | 2023年 / 24卷 / 05期
关键词
Techniques and procedures; neonatal intensive care; tip location; POCUS; intracavitary ECG; CENTRAL VENOUS CATHETERS; CONFIRMATION SYSTEM; PEDIATRIC-PATIENTS; ELECTROCARDIOGRAPHY; PLACEMENT; MALPOSITION; CHILDREN; POSITION; INFANTS; DEVICES;
D O I
10.1177/11297298211068302
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: The correct position of the tip of a central venous access device is important in all patients, and especially in neonates. The traditional method of tip location (approximated intra-procedural length estimation + post procedural chest X-ray) is currently considered inaccurate and not cost-effective by most recent guidelines, which recommend the adoption of tip location by intracavitary electrocardiography (IC-ECG) whenever possible. Methods: This study prospectively investigated the applicability, the feasibility, the accuracy, and the safety IC-ECG for tip location in neonates requiring insertion of ultrasound-guided centrally inserted central venous catheters (CICCs) with caliber 3Fr or more. All catheter tip locations were verified using simultaneously both IC-ECG and ultrasound-based tip location, using the Neo-ECHOTIP protocol. Results: A total of 105 neonates were enrolled. The applicability of IC-ECG was 100% since a P wave was evident on the surface ECG of all neonates recruited for the study. The feasibility was also 100% since an increase of the P-wave was detected in all cases. The accuracy was also 100%, since a perfect match between IC-ECG based tip location and ultrasound-based tip location was found. There were no adverse events directly or indirectly related to the IC-ECG technique; no arrhythmias occurred. Conclusions: When applied to ultrasound guided CICCs, tip location by IC-ECG is applicable and feasible in neonates, and it is safe and accurate.
引用
收藏
页码:1134 / 1139
页数:6
相关论文
共 50 条
  • [1] Ultrasound Guided Confirmation of Tip of Peripherally Inserted Central Catheter in Neonates
    Singh, Surjeet
    Venkatesh, H. A.
    Swamy, Ravi
    Nagesh, N. Karthik
    [J]. INDIAN PEDIATRICS, 2020, 57 (09) : 858 - 859
  • [2] Ultrasound Guided Confirmation of Tip of Peripherally Inserted Central Catheter in Neonates
    Surjeet Singh
    H. A. Venkatesh
    Ravi Swamy
    N. Karthik Nagesh
    [J]. Indian Pediatrics, 2020, 57 (9) : 858 - 859
  • [3] An accuracy study of the Intracavitary Electrocardiogram (IC-ECG) guided peripherally inserted central catheter tip placement among neonates
    Zhou, Lian-juan
    Xu, Hong-zhen
    Xu, Mei-fang
    Hu, Yan
    Lou, Xiao-fang
    [J]. OPEN MEDICINE, 2017, 12 (01): : 125 - 130
  • [4] Effects of indwelling centrally inserted central catheter on tip location of peripherally inserted central catheter with intracavitary electrocardiogram guidance: A retrospective case-control study
    Sun, Wenyan
    Li, Jiaqian
    Liu, Bing
    Liu, Yue
    Ge, Ruibin
    Wang, Kai
    Zhang, Jingyan
    Wu, Xinjuan
    [J]. JOURNAL OF VASCULAR ACCESS, 2023, 24 (03): : 379 - 384
  • [5] Peripherally inserted central catheter tip location in neonates.
    Fliman, P
    deRegnier, R
    DeUngria, M
    Shore, R
    Steinhorn, R
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2005, 53 (01) : S127 - S127
  • [6] Use of intracavitary-ECG for tip location of femorally inserted central catheters
    Weber, Mark D.
    Himebauch, Adam S.
    Conlon, Thomas
    [J]. JOURNAL OF VASCULAR ACCESS, 2022, 23 (01): : 166 - 170
  • [7] Intracavitary electrocardiography for femorally inserted central catheter tip location in adult patients
    Duan, YingFang
    Hu, XiaoYan
    Zhu, YuXin
    Zhao, Xi
    Yin, XinXin
    Zhang, HaiMan
    Wang, Yu
    [J]. ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2022, 27 (02)
  • [8] Effectiveness of Intracavitary Electrocardiogram Guidance in Peripherally Inserted Central Catheter Tip Placement in Neonates
    Zhou, Lianjuan
    Xu, Hongzhen
    Liang, Jianfeng
    Xu, Meifang
    Yu, Jun
    [J]. JOURNAL OF PERINATAL & NEONATAL NURSING, 2017, 31 (04) : 326 - 331
  • [9] Ultrasound-Guided Peripherally Inserted Central Catheter Placement in Extremely Low Birth Weight Neonates
    Johanna Fridolfsson, Pernilla Eva
    [J]. NEONATAL NETWORK, 2022, 41 (01): : 21 - 35
  • [10] Dynamic Needle Tip Positioning for Ultrasound-Guided Placement of a Peripherally Inserted Central Catheter in Pediatric Patients
    Takeshita, Jun
    Inata, Yu
    Ito, Yukie
    Nishiyama, Kei
    Shimizu, Yoshiyuki
    Takeuchi, Muneyuki
    Shime, Nobuaki
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (01) : 114 - 118