Multi-objective optimization of a Rectisol process integrated with compression-absorption cascade refrigeration system and ORC for waste heat recovery

被引:2
|
作者
Sun, Xiaojing [1 ,2 ]
Liu, Linlin [3 ]
Zhang, Tong [4 ]
Dai, Yanjun [1 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Sch Mech Engn, Shanghai 200240, Peoples R China
[2] Zhenghzou Univ Aeronaut, Inst Power Engn & Engn Thermophys, Sch Aeroengline, Zhengzhou 450005, Henan, Peoples R China
[3] Dalian Univ Technol, Inst Proc Syst Engn, Sch Chem Engn, Dalian 116023, Liaoning, Peoples R China
[4] Marine Design & Res Inst China, Shanghai 200011, Peoples R China
[5] Shanghai Jiao Tong Univ, Engn Res Ctr Solar Power & Refrigerat, Room A406,Dongchuan Rd 800, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Rectisol process; Compression-absorption cascade refrigeration; system; ORC; Waste heat recovery; Multi-objective optimization; COAL; GAS; SIMULATION;
D O I
10.1016/j.applthermaleng.2024.122611
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Rectisol is an essential component of coal to synthetic natural gas (SNG)/ methanol process, and its efficient utilization of energy is crucial for enhancing the energy efficiency and reducing the energy consumption in the entire coal to SNG/ methanol process. Therefore, a novel waste heat recovery system consisting of compressionabsorption cascade refrigeration system (CACRS), organic Rankine cycle (ORC) and heat exchanger network (HEN) is proposed for Rectisol process to achieve the efficient utilization of energy. To realize the optimal design for the waste heat recovery system of Rectisol process, a multi-objective optimization model is established with the aim of minimizing the total annualized cost (TAC) and total exergy destroy, while simultaneously optimizing the integration configuration and operating parameters. To overcome the solving difficulties caused by large scale model and multiple optimization variables, a decomposition strategy is proposed and applied in this paper. The optimal design of a Rectisol process including 13 hot streams and 13 cold streams is conducted. Compared with the optimal schemes given in the cited literature, the total amount of waste heat recovery is increased by 19.2 %, the cooling water consumption and low-temperature cold utility requirement are reduced by 100 % and 1.7 %, respectively, demonstrating the superiority of the proposed method in efficiency improvement and energy saving. With the implementation of multi-objective optimization, the optimal scheme with both good thermodynamic and economic performances is obtained with TAC of 11,082,365 $/y and Extotal
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Multi-objective optimization and thermo-economic analysis of an enhanced compression-absorption cascade refrigeration system and ORC integrated system for cooling and power cogeneration
    Sun, Xiaojing
    Liu, Linlin
    Dong, Yachao
    Zhuang, Yu
    Li, Jiao
    Du, Jian
    Yin, HongChao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 236
  • [2] Heat Exchanger Network Synthesis Integrated with Compression-Absorption Cascade Refrigeration System
    Sun, Xiaojing
    Liu, Linlin
    Zhuang, Yu
    Zhang, Lei
    Du, Jian
    [J]. PROCESSES, 2020, 8 (02)
  • [3] Compression-absorption cascade refrigeration system
    Fernández-Seara, J
    Sieres, J
    Vázquez, M
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (5-6) : 502 - 512
  • [4] Superstructure-Based Simultaneous Optimization of a Heat Exchanger Network and a Compression-Absorption Cascade Refrigeration System for Heat Recovery
    Sun, Xiaojing
    Liu, Linlin
    Dong, Yachao
    Zhuang, Yu
    Zhang, Lei
    Du, Jian
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (36) : 16017 - 16028
  • [5] Multi-objective Optimization of a Rectisol® Process
    Gatti, Manuele
    Martelli, Emanuele
    Marechal, Francois
    Consonni, Stefano
    [J]. 24TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PTS A AND B, 2014, 33 : 1249 - 1254
  • [6] Multi-objective optimization of regenerative ORC system integrated with thermoelectric generators for low-temperature waste heat recovery
    Aliahmadi, Mohammad
    Moosavi, Ali
    Sadrhosseini, Hani
    [J]. ENERGY REPORTS, 2021, 7 : 300 - 313
  • [7] Exergy analysis of a compression-absorption cascade system for refrigeration
    Colorado, D.
    Velazquez, V. M.
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (14) : 1851 - 1865
  • [8] Parametric analysis and optimization of a novel cascade compression-absorption refrigeration system integrated with a flash tank and a reheater
    Faruque, Md Walid
    Khan, Yasin
    Nabil, Mahdi Hafiz
    Ehsan, M. Monjurul
    [J]. RESULTS IN ENGINEERING, 2023, 17
  • [9] 4E analyses and multi-objective optimization of cascade refrigeration cycles with heat recovery system
    Mofrad, Kamyar Golbaten
    Zandi, Sina
    Salehi, Gholamreza
    Manesh, Mohammad Hasan Khoshgoftar
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 19
  • [10] Advanced Exergy Analysis of a Compression-Absorption Cascade Refrigeration System
    Colorado-Garrido, Dario
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2019, 141 (04):