Bifurcations of Grid-Following Rectifiers and Routes to Voltage Instability in Weak AC Grids

被引:5
|
作者
Yang, Jingxi [1 ]
Tse, Chi K. [1 ]
Huang, Meng [2 ]
Liu, Dong [1 ]
机构
[1] City Univ Hong Kong, Dept Elect Engn, Kowloon Tong, Hong Kong, Peoples R China
[2] Wuhan Univ, Sch Elect Engn & Automat, Wuhan 430072, Peoples R China
关键词
Bifurcation; Voltage control; Power system stability; Inverters; Phase locked loops; Stability analysis; Power system dynamics; Bautin bifurcation; center manifold; grid-following rectifier; saddle-node bifurcation of periodic orbits; supercritical and subcritical Hopf bifurcations; voltage instability; TRANSIENT STABILITY; SOURCE CONVERTER; VIRTUAL INERTIA;
D O I
10.1109/TPWRS.2022.3179287
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As indispensable components in modern power systems, grid-following rectifiers would interact with the grid. Such interaction, however, may lead to unexpected collapse of the ac bus voltage. In this paper, three routes to voltage instability are identified, namely, (i) supercritical Hopf bifurcation and successive saddle-node bifurcation of periodic orbits (SNPO); (ii) subcritical Hopf bifurcation; and (iii) departure from a stable basin of attraction. The SNPO and subcritical Hopf bifurcation are reported for the first time in rectifier-based power systems. It is also found that the rectifier-based system may undergo a Bautin bifurcation, which changes a Hopf bifurcation from supercritical to subcritical, or vice versa. The current loop of the grid-following rectifier has been found to play a crucial role in these bifurcation behaviors. Considering the inevitable and immediate voltage breakdown after the onset of a subcritical Hopf bifurcation, it is recommended to increase the bandwidth of the current loop to trigger the Bautin bifurcation, so that only supercritical Hopf bifurcation may occur. Furthermore, the original high-order and nonlinear model of the rectifier-based system can be simplified to a reduced order system by focusing on the center manifold. Based on the reduced system, the occurrence mode of Hopf bifurcation can be confirmed by inspecting the first Lyapunov coefficient. Finally, relevant bifurcation diagrams are derived, providing practical design guidelines to avoid an eventual system collapse.
引用
收藏
页码:1702 / 1713
页数:12
相关论文
共 50 条
  • [1] Comparison of Grid-Following and Grid-Forming Control in Weak AC System
    Wang, Zuohan
    Hibberts-Caswell, Richard
    Oprea, Liliana
    INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND ENERGY TECHNOLOGIES (ICECET 2021), 2021, : 1129 - 1133
  • [2] Comparison between DC Voltage Droop Schemes and Grid-Following & Grid-Forming Control in AC Systems in View of Interoperability of MTDC grids
    Shinodal, Kosei
    Elsodany, Mohamed
    Gonzalez, Juan -Carlos
    Dai, Jing
    Benchaibl, Abdelkrim
    Bachal, Seddik
    2023 25TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, EPE'23 ECCE EUROPE, 2023,
  • [3] Optimal Controllers to Improve Transient Recovery of Grid-Following Inverters Connected to Weak Power Grids
    Hathiyaldeniye, Thilini
    Karawita, Chandana
    Bagen, Bagen
    Pahalawaththa, Nalin
    Annakkage, Udaya D.
    IEEE OPEN ACCESS JOURNAL OF POWER AND ENERGY, 2022, 9 : 161 - 172
  • [4] Grid-Following DVI-Based Converter Operating in Weak Grids for Enhancing Frequency Stability
    Saeedian, Meysam
    Sangrody, Reza
    Shahparasti, Mahdi
    Taheri, Shamsodin
    Pouresmaeil, Edris
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (01) : 338 - 348
  • [5] Comparison of Homoclinic Bifurcations Between Grid-Following and Grid-Forming Converters
    Yang, Jingxi
    Tse, Chi K.
    Huang, Meng
    Liu, Dong
    Liu, Chao Charles
    Fu, Xikun
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (05) : 4731 - 4741
  • [6] Enhanced Grid-Following (E-GFL) Inverter: A Unified Control Framework for Stiff and Weak Grids
    Askarian, Alireza
    Park, Jaesang
    Salapaka, Srinivasa
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (05) : 5089 - 5107
  • [7] Robust Grid-Following Control with Active Delay Compensation in Weak Grid
    Li, Hong
    Wang, Zhenmin
    Li, Xiang
    Chen, Yan
    Kong, Fannie
    Chen, Yanming
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2024, 19 (07) : 4357 - 4367
  • [8] Investigation on grid-following and grid-forming control schemes of cascaded hybrid converter for wind power integrated with weak grids
    He, Yongjie
    Xiang, Wang
    Meng, Peiyu
    Wen, Jinyu
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [9] Voltage and Current Dynamics Cancellation of Weak-Grid-Tied Grid-Following Inverters for Maximum Transferable Power Improvement
    Zhou, Weihua
    Mohammed, Nabil
    Bahrani, Behrooz
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2024, 39 (03) : 2053 - 2067
  • [10] Tuning Method of a Grid-Following Converter for the Extremely-Weak-Grid Connection
    Li, Chuanyue
    Wang, Sheng
    Liang, Jun
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2022, 37 (04) : 3169 - 3172