GEC-ESTRO survey of 106Ru eye applicator practice for ocular melanoma - Physicist survey

被引:4
|
作者
De Brabandere, Marisol [1 ,12 ]
Placidi, Elisa [2 ]
Siebert, Frank-Andre [3 ]
Tedgren, asa Carlsson [4 ,5 ,6 ]
Escarpa, Andrea Slocker [7 ]
Tagliaferri, Luca [8 ]
Andr, Michael
Schulz, Carmen [9 ]
Fog, Lotte S. [10 ,11 ]
机构
[1] Univ Hosp Leuven, Dept Radiat Oncol, Leuven, Belgium
[2] Univ Hosp Schleswig Holstein, Fdn Policlin Univ Agostino Gemelli, UOC Phys Life Sci Diagnost Imaging, Oncol Radiotherapy & Hematol,IRCCS, Rome, Italy
[3] Univ Hosp Schleswig Holstein, Clin Radiotherapy Radiooncol, Campus Kiel, Kiel, Germany
[4] Linkoping Univ, Dept Hlth Med & Caring Sci, Radiat Phys, Linkoping, Sweden
[5] Karolinska Univ Hosp, Med Radiat Phys & Nucl Med, Stockholm, Sweden
[6] Karolinska Inst, Dept Oncol Pathol, Stockholm, Sweden
[7] Catalan Inst Oncol, Dept Radiat Oncol, Barcelona, Spain
[8] Fdn Policlin Univ A Gemelli IRCCS, Intervent Oncol Ctr IOC, Gemelli ART Adv Radiat Therapy, Rome, Italy
[9] Eckert & Ziegler BEBIG GmbH, Robert-Rossle-Str 10, D-13125 Berlin, Germany
[10] Royal Victorian Eye & Ear Hosp, Ocular oncol unit, Melbourne, Vic, Australia
[11] Alfred Hlth, Radiat Oncol, Melbourne, Vic, Australia
[12] Univ Hosp Leuven, Dept Radiat Oncol, Herestr 49, B-3000 Leuven, Belgium
关键词
Brachytherapy; Eye plaque; Ocular melanoma; EMITTING BRACHYTHERAPY SOURCES; PLAQUE BRACHYTHERAPY; UVEAL MELANOMA; ACROP RECOMMENDATIONS; RADIATION; TRACEABILITY; CALIBRATION; THERAPY; CANCER; I-125;
D O I
10.1016/j.radonc.2024.110114
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: 106Ru eye plaque brachytherapy (BT, interventional radiotherapy) is an eye-preserving treatment for uveal melanoma performed in about 100 clinics worldwide. Despite this relatively low number, there is a considerable variation in clinical practice. In 2022, the BRAPHYQS and Head & Neck and Skin GEC-ESTRO working groups conducted a survey to map the current clinical practice. The survey consisted of a physicist and a physician part. This paper describes the physicist results. However, three physician questions with overlapping interest are included here as well. Materials and Methods: The survey questions pertained to commissioning and quality control (QC) of the plaques, treatment planning, radiobiological correction, as well as more general questions on practice improvement. The questions overlapping with the physician survey were related to dose prescription and margins. Results: Sixty-five physicist responses were included. A majority of the centres do not perform an independent measurement of the absorbed dose at reference depth, percentage depth dose (PDD) and off-axis data. A lack of calibration services and suitable equipment are the main reasons. About one third of the centres indicated that they do image based treatment planning. The use of margins and dose prescription showed a large variability, despite the availability of guidelines [1]. Many respondents expressed a strong wish for improvement in a wide range of aspects of clinical practice. Conclusion: The physics survey showed a wide variability regarding quality control of the 106Ru sources and treatment planning practice.
引用
收藏
页数:6
相关论文
共 8 条
  • [1] GEC-ESTRO survey on global Ru-106 eye plaque brachytherapy practice
    Fog, L. S.
    De Brabandere, M.
    Placidi, E.
    Slocker, A.
    Tagliaferri, L.
    Tedgren, A. C.
    Andrassy, M.
    Schulz, C.
    Chimfwembe, E. C.
    Siebert, F.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S464 - S465
  • [2] The current status of brachytherapy in Europe - A GEC-ESTRO Brachy-HERO survey
    Johansen, J. G.
    Jurgenliemk-Schulz, I. M.
    Haddad, H.
    Hannoun-Levi, J. M.
    Hellebust, T. P.
    Guix, B.
    Loessl, K.
    Pieters, B.
    Rao, C.
    Strnad, V.
    Sturdza, A. E.
    Tagliaferri, L.
    Takacsi-Nagy, Z.
    Villafranca, E.
    Wojcieszek, P.
    Rembielak, A.
    Niehoff, P.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2025, 50
  • [3] The global Ruthenium Eye applicator survey - physicist responses
    Fog, L. S.
    De Brabandere, M.
    Placidi, E.
    Slocker, A.
    Tagliaferri, L.
    Tedgren, A. . C.
    Andrassy, M.
    Schulz, C.
    Chimfwembe, E. C.
    Siebert, F.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S522 - S523
  • [4] The three-dimensional scintillation dosimetry method:: test for a 106Ru eye plaque applicator
    Kirov, AS
    Piao, JZ
    Mathur, NK
    Miller, TR
    Devic, S
    Trichter, S
    Zaider, M
    Soares, CG
    LoSasso, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13): : 3063 - 3081
  • [5] 106Ru/106Rh Plaque and proton radiotherapy for ocular melanoma:: A comparative dosimetric study
    Mourtada, F
    Koch, N
    Newhauser, W
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 454 - 460
  • [6] Energy deposition by a 106Ru/106Rh eye applicator simulated using LEPTS, a low-energy particle track simulation
    Fuss, M. C.
    Munoz, A.
    Oller, J. C.
    Blanco, F.
    Williart, A.
    Limao-Vieira, P.
    Borge, M. J. G.
    Tengblad, O.
    Huerga, C.
    Tellez, M.
    Garcia, G.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (09) : 1198 - 1204
  • [7] Ru-106 eye plaques for treatment of ocular melanoma - Practical issues
    Mourtada, F.
    Horton, J.
    Gombos, D.
    Garden, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S696 - S696
  • [8] Visual outcome, local tumour control, and eye preservation after 106Ru/Rh brachytherapy for choroidal melanoma
    Isager, P
    Ehlers, N
    Urbak, SF
    Overgaard, J
    ACTA ONCOLOGICA, 2006, 45 (03) : 285 - 293