Reprojection Error Analysis and Algorithm Optimization of Hand-Eye Calibration for Manipulator System

被引:3
|
作者
Peng, Gang [1 ,2 ]
Ren, Zhenyu [1 ,2 ]
Gao, Qiang [1 ,2 ]
Fan, Zhun [2 ,3 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Artificial Intelligence & Automation, Wuhan 430074, Peoples R China
[2] Minist Educ, Key Lab Image Proc & Intelligent Control, Wuhan 430074, Peoples R China
[3] Shantou Univ, Coll Engn, Shantou 515063, Peoples R China
关键词
hand-eye calibration; reprojection error analysis; manipulator object grasping; SELF-CALIBRATION; ROBOT; RECONSTRUCTION;
D O I
10.3390/s24010113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Euclidean distance error of calibration results cannot be calculated during the hand-eye calibration process of a manipulator because the true values of the hand-eye conversion matrix cannot be obtained. In this study, a new method for error analysis and algorithm optimization is presented. An error analysis of the method is carried out using a priori knowledge that the location of the augmented reality markers is fixed during the calibration process. The coordinates of the AR marker center point are reprojected onto the pixel coordinate system and then compared with the true pixel coordinates of the AR marker center point obtained by corner detection or manual labeling to obtain the Euclidean distance between the two coordinates as the basis for the error analysis. We then fine-tune the results of the hand-eye calibration algorithm to obtain the smallest reprojection error, thereby obtaining higher-precision calibration results. The experimental results show that, compared with the Tsai-Lenz algorithm, the optimized algorithm in this study reduces the average reprojection error by 44.43% and the average visual positioning error by 50.63%. Therefore, the proposed optimization method can significantly improve the accuracy of hand-eye calibration results.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Hand-Eye Calibration Algorithm Based on an Optimized Neural Network
    Hua, Jiang
    Zeng, Liangcai
    ACTUATORS, 2021, 10 (04)
  • [32] Manipulator Calibration-Free Hand-Eye Coordination Based on ADRC Under Eye Fixation
    Wang, Lijun
    Cao, Tianyu
    Yan, Jiaxuan
    Liu, Ningxi
    Lecture Notes in Electrical Engineering, 2021, 705 LNEE : 270 - 277
  • [33] Iterative Refinement of Hand-Eye Calibration
    Liska, Jindrich
    Chalus, Michal
    Vanicek, Ondrej
    2018 IEEE 14TH INTERNATIONAL CONFERENCE ON AUTOMATION SCIENCE AND ENGINEERING (CASE), 2018, : 457 - 462
  • [34] Globally Optimal Hand-Eye Calibration
    Ruland, Thomas
    Pajdla, Tomas
    Krueger, Lars
    2012 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2012, : 1035 - 1042
  • [35] Simultaneous Hand-Eye Calibration and Reconstruction
    Zhi, Xiangyang
    Schwertfeger, Soren
    2017 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2017, : 1470 - 1477
  • [36] AN AUTONOMOUS HAND-EYE CALIBRATION METHOD
    Cheng, Yuli
    Zhang, Yifeng
    Wang, Peng
    Xiong, Rong
    ASSISTIVE ROBOTICS, 2016, : 545 - 554
  • [37] A new approach to hand-eye calibration
    Malm, H
    Heyden, A
    15TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 1, PROCEEDINGS: COMPUTER VISION AND IMAGE ANALYSIS, 2000, : 525 - 529
  • [38] Error Analysis of Binocular Active Hand-eye Visual System on Parallel mechanisms
    Zhao, Liqiang
    Kong, Lingfu
    Wang, Yueming
    2008 INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, VOLS 1-4, 2008, : 95 - +
  • [39] An Improved Robust Hand-Eye Calibration for Endoscopy Navigation System
    He, Wei
    Kang, Kumsok
    Li, Yanfang
    Shi, Weili
    Miao, Yu
    He, Fei
    Yan, Fei
    Yang, Huamin
    Zhang, Huimao
    Mori, Kensaku
    Jiang, Zhengang
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [40] A Method for Hand-Eye Calibration of a Robot Vision Measuring System
    Liu, Yan
    Wang, Qinglin
    Li, Yuan
    2015 10TH ASIAN CONTROL CONFERENCE (ASCC), 2015,