Comparison of Sonodynamic Treatment Set-Ups for Cancer Cells with Organic Sonosensitizers and Nanosonosensitizers

被引:2
|
作者
Radivoievych, Aleksandar [1 ,2 ,3 ]
Prylutska, Svitlana [4 ]
Zolk, Oliver [2 ,3 ,5 ]
Ritter, Uwe [6 ]
Frohme, Marcus [1 ]
Grebinyk, Anna [1 ,7 ]
机构
[1] Tech Univ Appl Sci Wildau, Div Mol Biotechnol & Funct Genom, Hochschulring 1, D-15745 Wildau, Germany
[2] Brandenburg Med Sch Theodor Fontane, Joint Fac Brandenburg Univ Technol Cottbus Senften, Fac Hlth Sci, D-14476 Potsdam, Germany
[3] Univ Potsdam, D-14476 Potsdam, Germany
[4] Natl Univ Life & Environm Sci Ukraine, Dept Plants Physiol Biochem & Bioenerget, Heroyiv Oborony Str 15, UA-03041 Kiev, Ukraine
[5] Brandenburg Med Sch, Inst Clin Pharmacol, Immanuel Klin Ruedersdorf, D-15562 Ruedersdorf, Germany
[6] Tech Univ Ilmenau, Inst Chem & Biotechnol, D-98693 Ilmenau, Germany
[7] DESY, Platanenallee 6, D-15738 Zeuthen, Germany
关键词
ultrasound; C-60; fullerene; berberine; sonodynamic therapy; apoptosis; INTENSITY FOCUSED ULTRASOUND; IN-VITRO; CARBON NANOTUBES; FULLERENES C-60; THERAPY; BERBERINE; APOPTOSIS; WATER; SONOLUMINESCENCE; BUBBLE;
D O I
10.3390/pharmaceutics15112616
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Cancer sonodynamic therapy (SDT) is the therapeutic strategy of a high-frequency ultrasound (US) combined with a special sonosensitizer that becomes cytotoxic upon US exposure. The growing number of newly discovered sonosensitizers and custom US in vitro treatment solutions push the SDT field into a need for systemic studies and reproducible in vitro experimental set-ups. In the current research, we aimed to compare two of the most used and suitable SDT in vitro set-ups-"sealed well" and "transducer in well"-in one systematic study. We assessed US pressure, intensity, and temperature distribution in wells under US irradiation. Treatment efficacy was evaluated for both set-ups towards cancer cell lines of different origins, treated with two promising sonosensitizer candidates-carbon nanoparticle C-60 fullerene (C-60) and herbal alkaloid berberine. C-60 was found to exhibit higher sonotoxicity toward cancer cells than berberine. The higher efficacy of sonodynamic treatment with a "transducer in well" set-up than a "sealed well" set-up underlined its promising application for SDT in vitro studies. The "transducer in well" set-up is recommended for in vitro US treatment investigations based on its US-field homogeneity and pronounced cellular effects. Moreover, SDT with C-60 and berberine could be exploited as a promising combinative approach for cancer treatment.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Inorganic Sonosensitizers for Sonodynamic Therapy in Cancer Treatment
    Cao, Xianshuo
    Li, Minxing
    Liu, Qiyu
    Zhao, Jingjing
    Lu, Xihong
    Wang, Jianwei
    SMALL, 2023, 19 (42)
  • [2] A systematic comparison of experimental set-ups for modelling extensional tectonics
    Zwaan, Frank
    Schreurs, Guido
    Buiter, Susanne J. H.
    SOLID EARTH, 2019, 10 (04) : 1063 - 1097
  • [3] COMPARISON OF SOURCE PLASMA QUALITY IN THREE DIFFERENT APHERESIS SET-UPS
    Kiessig, T.
    Hellstern, P.
    Krause, K-P
    VOX SANGUINIS, 2012, 103 : 130 - 130
  • [4] Comparison of different passive horizontal sprayer boom suspension set-ups
    Kennes, P
    Vermeulen, K
    Clijmans, L
    Ramon, H
    CONTROL APPLICATIONS & ERGONOMICS IN AGRICULTURE, 1999, : 307 - 311
  • [5] Comparison of Set-ups Dedicated to Measure Thermal Parameters of Power LEDs
    Gorecki, Krzysztof
    Ptak, Przemyslaw
    Janicki, Marcin
    PROCEEDINGS OF 2020 27TH INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEM (MIXDES), 2020, : 127 - 132
  • [6] TECH 20-Hints and tips for organic synthesis appratus set-ups
    Shanks, Thomas
    Moore, Mary K.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 232
  • [7] A comprehensive theoretical comparison of proton imaging set-ups in terms of spatial resolution
    Krah, N.
    Khellaf, F.
    Letang, J. M.
    Rit, S.
    Rinaldi, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (13):
  • [8] Comparison of five different set-ups for statistical-dynamic surface temperature forecasts
    Verret, R
    Turcotte, MF
    Desautels, G
    14TH CONFERENCE ON PROBABILITY AND STATISTICS IN THE ATMOSPHERIC SCIENCES, 1998, : 173 - 177
  • [9] A comparison of diesel soot oxidation rates measured with two different isothermal set-ups
    Seher, Simone I.
    Ess, Michaela N.
    Bladt, Henrike
    Niessner, Reinhard
    Eigenberger, Gerhart
    Nieken, Ulrich
    JOURNAL OF AEROSOL SCIENCE, 2016, 91 : 94 - 100
  • [10] A comparison of dynamic atomic force microscope set-ups for performing atomic scale manipulation experiments
    Trevethan, T.
    Watkins, M.
    Shluger, A. L.
    Polesel-Maris, J.
    Gauthier, S.
    Kantorovich, L. N.
    NANOTECHNOLOGY, 2007, 18 (34)