Negative-Sequence Current Compensation-Based Coordinated Control Strategy for Dual-Cage-Rotor Brushless Doubly Fed Induction Generator Under Unbalanced Grid Conditions

被引:6
|
作者
Cheng, Ming [1 ]
Yan, Xiaoming [1 ]
Zhou, Jiawei [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Rotors; Voltage control; Doubly fed induction generators; PI control; Reactive power; Wind turbines; Voltage; Brushless doubly fed induction generator (BDFIG); coordinated control; negative-sequence current compensation; unbalanced grid voltage;
D O I
10.1109/TIE.2022.3186317
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this article, we propose a negative-sequence current compensation-based coordinated control strategy for dual-cage-rotor brushless doubly fed induction generator, where the machine-side converter (MSC) and the grid-side converter (GSC) cooperate to mitigate the imbalance in the control winding current, total output power, and total grid current. Based on the machine dynamic model withstanding unbalanced grid voltage, the negative-sequence current references, including four targets for MSC and three targets for GSC, are calculated and sent to the inner-current-loop controllers, where the GSC current controller is designed based on the supertwisting sliding-mode control with the stability analyzed. This proposed control strategy omits the outer-loop controller in the negative-sequence frame, which has a more simple control structure and becomes more easy-implemented. Finally, the whole proposed coordinated control system is designed and implemented in both simulation and experiments under unbalanced grid conditions, verifying the effectiveness of the proposed control strategy.
引用
收藏
页码:4762 / 4773
页数:12
相关论文
共 50 条
  • [1] Multi-objective Control of Dual-cage-rotor Brushless Doubly Fed Induction Generator Under Unbalanced Grid Voltage
    Cao Z.
    Cheng M.
    Yan X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (01): : 293 - 303
  • [2] Dual-negative-objective Coordinated Control of Brushless Doubly Fed Induction Generator under Unbalanced Grid Voltage
    Cheng, Ming
    Cao, Zheng
    Yan, Xiaoming
    CES TRANSACTIONS ON ELECTRICAL MACHINES AND SYSTEMS, 2024, 8 (03) : 347 - 355
  • [3] Dual-negative-objective Coordinated Control of Brushless Doubly Fed Induction Generator under Unbalanced Grid Voltage
    Ming Cheng
    Zheng Cao
    Xiaoming Yan
    CES Transactions on Electrical Machines and Systems, 2024, 8 (03) : 347 - 355
  • [4] Negative Sequence Control Strategy for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Conditions
    Park, Yonggyun
    Han, Daesu
    Suh, Yongsug
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 1118 - 1124
  • [5] Robust Predictive Rotor Current Control of a Doubly Fed Induction Generator Under an Unbalanced and Distorted Grid
    Zhang, Yongchang
    Jiang, Tao
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (01) : 433 - 442
  • [6] Dual Synchronous Rotating Frame Current Control of Brushless Doubly Fed Induction Generator Under Unbalanced Network
    Xu, Litong
    Cheng, Ming
    Wei, Xinchi
    Yan, Xiaoming
    Zeng, Yu
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (06) : 6712 - 6724
  • [7] Backstepping-Based Direct Power Control for Dual-Cage Rotor Brushless Doubly Fed Induction Generator
    Yan, Xiaoming
    Cheng, Ming
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (02) : 2668 - 2680
  • [8] Coordinated control of grid- and rotor-side converters of doubly-fed induction generator under unbalanced network voltage conditions
    Hu, Jia-Bing
    He, Yi-Kang
    Wang, Hong-Sheng
    Lie, Xu
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (09): : 97 - 104
  • [9] A Vector Control Strategy of Grid-Connected Brushless Doubly Fed Induction Generator Based on the Vector Control of Doubly Fed Induction Generator
    Hu, Sheng
    Zhu, Guorong
    APEC 2016 31ST ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, 2016, : 3310 - 3316
  • [10] Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    Brekken, Ted K. A.
    Mohan, Ned
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 129 - 135