CBCT-Based synthetic CT image generation using conditional denoising diffusion probabilistic model

被引:15
|
作者
Peng, Junbo [1 ,2 ,3 ,4 ]
Qiu, Richard L. J. [1 ,2 ]
Wynne, Jacob F. [1 ,2 ]
Chang, Chih-Wei [1 ,2 ]
Pan, Shaoyan [1 ,2 ]
Wang, Tonghe [5 ]
Roper, Justin [1 ,2 ]
Liu, Tian [6 ]
Patel, Pretesh R. [1 ,2 ]
Yu, David S. [1 ,2 ]
Yang, Xiaofeng [1 ,2 ,3 ,4 ,7 ,8 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA USA
[2] Emory Univ, Winship Canc Inst, Atlanta, GA USA
[3] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Nucl & Radiol Engn Program, Atlanta, GA USA
[4] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Med Phys Programs, Atlanta, GA USA
[5] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY USA
[6] Icahn Sch Med Mt Sinai, Dept Radiat Oncol, New York, NY USA
[7] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[8] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
CBCT; diffusion model; synthetic CT; CONE-BEAM CT; METAL ARTIFACT REDUCTION; SCATTER CORRECTION;
D O I
10.1002/mp.16704
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundDaily or weekly cone-beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image-guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART) replanning. However, the presence of severe artifacts and inaccurate Hounsfield unit (HU) values prevent its use for quantitative applications such as organ segmentation and dose calculation. To enable the clinical practice of online ART, it is crucial to obtain CBCT scans with a quality comparable to that of a CT scan.PurposeThis work aims to develop a conditional diffusion model to perform image translation from the CBCT to the CT distribution for the image quality improvement of CBCT.MethodsThe proposed method is a conditional denoising diffusion probabilistic model (DDPM) that utilizes a time-embedded U-net architecture with residual and attention blocks to gradually transform the white Gaussian noise sample to the target CT distribution conditioned on the CBCT. The model was trained on deformed planning CT (dpCT) and CBCT image pairs, and its feasibility was verified in brain patient study and head-and-neck (H&N) patient study. The performance of the proposed algorithm was evaluated using mean absolute error (MAE), peak signal-to-noise ratio (PSNR) and normalized cross-correlation (NCC) metrics on generated synthetic CT (sCT) samples. The proposed method was also compared to four other diffusion model-based sCT generation methods.ResultsIn the brain patient study, the MAE, PSNR, and NCC of the generated sCT were 25.99 HU, 30.49 dB, and 0.99, respectively, compared to 40.63 HU, 27.87 dB, and 0.98 of the CBCT images. In the H&N patient study, the metrics were 32.56 HU, 27.65 dB, 0.98 and 38.99 HU, 27.00, 0.98 for sCT and CBCT, respectively. Compared to the other four diffusion models and one Cycle generative adversarial network (Cycle GAN), the proposed method showed superior results in both visual quality and quantitative analysis.ConclusionsThe proposed conditional DDPM method can generate sCT from CBCT with accurate HU numbers and reduced artifacts, enabling accurate CBCT-based organ segmentation and dose calculation for online ART.
引用
收藏
页码:1847 / 1859
页数:13
相关论文
共 50 条
  • [1] CBCT-based synthetic CT image generation using a diffusion model for CBCT-guided lung radiotherapy
    Chen, Xiaoqian
    Qiu, Richard L. J.
    Peng, Junbo
    Shelton, Joseph W.
    Chang, Chih-Wei
    Yang, Xiaofeng
    Kesarwala, Aparna H.
    [J]. MEDICAL PHYSICS, 2024,
  • [2] CT-based synthetic iodine map generation using conditional denoising diffusion probabilistic model
    Gao, Yuan
    Xie, Huiqiao
    Chang, Chih-Wei
    Peng, Junbo
    Pan, Shaoyan
    Qiu, Richard L. J.
    Wang, Tonghe
    Ghavidel, Beth
    Roper, Justin
    Zhou, Jun
    Yang, Xiaofeng
    [J]. MEDICAL PHYSICS, 2024, : 6246 - 6258
  • [3] CT-based synthetic contrast-enhanced dual-energy CT generation using conditional denoising diffusion probabilistic model
    Gao, Yuan
    Qiu, Richard L. J.
    Xie, Huiqiao
    Chang, Chih-Wei
    Wang, Tonghe
    Ghavidel, Beth
    Roper, Justin
    Zhou, Jun
    Yang, Xiaofeng
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (16):
  • [4] Ultra-low Dose CT Image Denoising based on Conditional Denoising Diffusion Probabilistic model
    Li, Qiwei
    Li, Chen
    Yan, Chenggong
    Li, Xiaomei
    Li, Haixia
    Zhang, Tianjing
    Song, Hui
    Schaffert, Roman
    Yu, Weimin
    Fan, Yu
    Yee, Jianwei
    Chen, Hao
    [J]. 2022 INTERNATIONAL CONFERENCE ON CYBER-ENABLED DISTRIBUTED COMPUTING AND KNOWLEDGE DISCOVERY, CYBERC, 2022, : 198 - 205
  • [5] CBCT-based synthetic CT generation using generative adversarial networks with disentangled representation
    Liu, Jiwei
    Yan, Hui
    Cheng, Hanlin
    Liu, Jianfei
    Sun, Pengjian
    Wang, Boyi
    Mao, Ronghu
    Du, Chi
    Luo, Shengquan
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (12) : 4820 - +
  • [6] DiffWater: Underwater Image Enhancement Based on Conditional Denoising Diffusion Probabilistic Model
    Guan, Meisheng
    Xu, Haiyong
    Jiang, Gangyi
    Yu, Mei
    Chen, Yeyao
    Luo, Ting
    Zhang, Xuebo
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2024, 17 : 2319 - 2335
  • [7] Cone-beam Computed Tomography (CBCT) and CT Image Registration Aided by CBCT-based Synthetic CT
    Fu, Yabo
    Lei, Yang
    Liu, Yingzi
    Wang, Tonghe
    Curran, Walter J.
    Liu, Tian
    Patel, Pretesh
    Yang, Xiaofeng
    [J]. MEDICAL IMAGING 2020: IMAGE PROCESSING, 2021, 11313
  • [8] Streaking artifact reduction for CBCT-based synthetic CT generation in adaptive radiotherapy
    Gao, Liugang
    Xie, Kai
    Sun, Jiawei
    Lin, Tao
    Sui, Jianfeng
    Yang, Guanyu
    Ni, Xinye
    [J]. MEDICAL PHYSICS, 2023, 50 (02) : 879 - 893
  • [9] Assessment of CBCT-based synthetic CT generation accuracy for adaptive radiotherapy planning
    O'Hara, Christopher J.
    Bird, David
    Al-Qaisieh, Bashar
    Speight, Richard
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (11):
  • [10] PET image denoising based on denoising diffusion probabilistic model
    Kuang Gong
    Keith Johnson
    Georges El Fakhri
    Quanzheng Li
    Tinsu Pan
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2024, 51 : 358 - 368