Optical monitoring of hemodialysis using noninvasive measurement of uric acid in the dialysate

被引:0
|
作者
Zylka, Wojciech [1 ]
Tecza, Krystyna [2 ]
Szemela, Krzysztof [3 ]
Prach, Piotr [4 ]
Zylka, Marta [5 ]
Jakubczyk, Dorota [6 ]
Bladzinski, Maciej [2 ]
Gala-Bladzinska, Agnieszka [2 ,7 ]
Jakubczyk, Pawel [3 ]
机构
[1] Univ Rzeszow, Inst Mat Engn, Coll Nat Sci, Rzeszow, Poland
[2] Rzeszow Univ, Inst Med Sci, Med Coll, Rzeszow, Poland
[3] Univ Rzeszow, Inst Phys, Coll Nat Sci, Rzeszow, Poland
[4] Univ Informat Technol & Management Rzeszow, Rzeszow, Poland
[5] Rzeszow Univ Technol, Fac Mech Engn & Aeronaut, Dept Aerosp Engn, Rzeszow, Poland
[6] Rzeszow Univ Technol, Fac Math & Appl Phys, Rzeszow, Poland
[7] St Queen Jadwiga Clin Dist Hosp 2 Rzeszow, Dept Internal Med Nephrol & Endocrinol, Rzeszow, Poland
关键词
ULTRAVIOLET ABSORBENCY; MORTALITY; SOLUTES; MODEL;
D O I
10.1038/s41598-023-40335-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to present a methodology for predicting changes in uric acid concentrations in the blood of chronically hemodialyzed patients based on an optical measurement of the intensity of selected wavelengths in the dialysate. Blood samples were taken from the arterial line every 30 min throughout the hemodialysis period, to measure uric acid levels. Simultaneously, optical measurements were made on dialysate flowing from the dialyzer. Uric acid concentration can be measured either directly from the blood or from dialyzer outflow with acceptable error. In addition, both methods reveal any increased dynamics in uric acid concentration in the initial phase of hemodialysis. The wavelength of the light was adjusted for optimal uric acid particle detection. Comparing the uric acid concentration measured in the blood of patients with the intensity of wave absorption in the dialysate, the functional relationship between the uric acid concentration levels was determined. Using the optical method for measuring uric acid concentration in the dialysate, the concentration of uric acid in the blood during hemodialysis can be non-invasively and accurately estimated. This method can be used to assess the adequacy of hemodialysis by computer acquisition of uric acid concentrations determined in on-line dialysate.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Optical monitoring of hemodialysis using noninvasive measurement of uric acid in the dialysate
    Wojciech Żyłka
    Krystyna Tęcza
    Krzysztof Szemela
    Piotr Prach
    Marta Żyłka
    Dorota Jakubczyk
    Maciej Błądziński
    Agnieszka Gala-Błądzińska
    Paweł Jakubczyk
    [J]. Scientific Reports, 13
  • [2] ON-LINE MONITORING OF URIC ACID CONCENTRATION IN SPENT DIALYSATE DURING HEMODIALYSIS ACCOMPANIED BY GRADUATED PHYSICAL EXERCISES WITH THE BISPECTRAL OPTICAL SENSOR
    Vasilevsky, Aleksandr
    Konoplev, Georgy
    Lopatenko, Oksana
    Komashnya, Artemy
    Visnevsky, Konstantin
    Gerasimchuk, Roman
    Neivelt, Indrek
    Frorip, Aleksandr
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 208 - 209
  • [3] Non-invasive determination of uric acid in blood during hemodialysis with an optical spent dialysate sensor
    Paats, Joosep
    Arund, Jurgen
    Adoberg, Annika
    Holmar, Jana
    Leis, Liisi
    Luman, Merike
    Pilt, Kristjan
    Tanner, Risto
    Fridolin, Ivo
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 : I1236 - I1237
  • [4] Optical Real-Time Cardiorenal Toxin Uric Acid Measurement During Hemodialysis Using a Miniaturized Optical Sensor
    Holmar, Jana
    Arund, Jurgen
    Adoberg, Annika
    Leis, Liisi
    Luman, Merike
    Paats, Joosep
    Pilt, Kristjan
    Tanner, Risto
    Fridolin, Ivo
    [J]. 2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [5] Dual-Wavelength Optoelectronic Sensor for Monitoring Uric Acid Concentration in Dialysate
    Vasilevsky A.M.
    Gerasimchuk R.P.
    Zemchenkov A.Y.
    Konoplev G.A.
    Rubinsky A.V.
    Stepanova O.S.
    Frorip A.A.
    [J]. Biomedical Engineering, 2015, 49 (03) : 125 - 128
  • [6] Noninvasive and Individual-Centered Monitoring of Uric Acid for Precaution of Hyperuricemia via Optical Supramolecular Sensing
    Zhang, Yaping
    Yu, Huijuan
    Chai, Shiwei
    Chai, Xin
    Wang, Luyao
    Geng, Wen-Chao
    Li, Juan-Juan
    Yue, Yu-Xin
    Guo, Dong-Sheng
    Wang, Yuefei
    [J]. ADVANCED SCIENCE, 2022, 9 (18)
  • [7] HEMODIALYSIS OF URIC-ACID
    CHALMERS, RA
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1977, 267 (01): : P26 - P27
  • [8] A new monitoring system of urea in a waste dialysate for hemodialysis
    Ozaki, M.
    Okabayashi, T.
    Ishimaru, T.
    Hayashi, K.
    Hori, J.
    Nakagawa, M.
    [J]. BLOOD PURIFICATION, 2007, 25 (04) : 347 - 347
  • [9] Optical Online Monitoring of Uric Acid Removal during Dialysis
    Jerotskaja, Jana
    Uhlin, Fredrik
    Fridolin, Ivo
    Lauri, Kai
    Luman, Merike
    Fernstrom, Anders
    [J]. BLOOD PURIFICATION, 2010, 29 (01) : 69 - 74
  • [10] Optical measurement of creatinine in spent dialysate
    Tomson, Ruth
    Fridolin, Ivo
    Uhlin, Fredrik
    Holmar, Jana
    Lauri, Kai
    Luman, Merike
    [J]. CLINICAL NEPHROLOGY, 2013, 79 (02) : 107 - 117