Therapeutic Drug Monitoring in Oncohematological Patients: A Fast and Accurate HPLC-UV Method for the Quantification of Nilotinib in Human Plasma and Its Clinical Application

被引:4
|
作者
Escudero-Ortiz, Vanesa [1 ]
Rodriguez-Lucena, Francisco Jose [1 ,2 ]
Estan-Cerezo, Gabriel [2 ]
Mancheno-Macia, Esther [1 ]
Conesa-Garcia, Venancio [3 ]
Garcia-Monsalve, Ana [2 ]
Soriano-Irigaray, Leticia [2 ]
Navarro-Ruiz, Andres [2 ]
机构
[1] Univ CEU Cardenal Herrera, Pharm & Clin Nutr Grp, Alicante 03204, Spain
[2] Hosp Gen Univ Elche FISABIO, Pharm Serv, Alicante 03203, Spain
[3] Hosp Gen Univ Elche FISABIO, Hematol Serv, Alicante 03203, Spain
关键词
therapeutic drug monitoring; nilotinib; HPLC-UV; analitycal method; pharmacokinetic; cancer; TYROSINE KINASE INHIBITORS; PERFORMANCE LIQUID-CHROMATOGRAPHY; ULTRAVIOLET DETECTION; PHARMACOKINETICS; VALIDATION; SORAFENIB; LEUKEMIA; IMATINIB; CANCER; FOCUS;
D O I
10.3390/biomedicines11030947
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Nilotinib, a second-generation tyrosine kinase inhibitor, has demonstrated clinical activity in chronic myeloid leukemia. As an exposure-response relationship has been observed for nilotinib, its therapeutic drug monitoring could be a valuable tool in clinical practice. Therefore, the aim of this study was to develop and validate a selective and precise high performance liquid chromatography-ultraviolet method for the measurement of nilotinib in plasma from patients with cancer. After protein precipitation extraction with acetonitrile, nilotinib and rilpivirine were separated using isocratic elution on a Tracer Excel 120 ODS C18 column using a mobile phase consisting of a mixture of potassium dihydrogen phosphate-buffered solution (pH 5.5; 0.037 M)-methanol-acetonitrile (45:45:10, v/v/v), pumped at a flow rate of 1.7 mL center dot min(-1). A wavelength of 254 nm was selected for the quantification of the analyte and the internal standard (IS). The technique was validated following the guidelines for the validation of analytical methods of regulatory agencies (Food and Drug Administration (FDA) and the European Medicines Agency (EMA)). Linearity was established in a concentration range between 125 and 7000 ng/mL. The detection limit was 90 ng/mL, and the lower limit of quantification was 125 ng/mL. For all concentrations in the calibration curve, the intraday and interday coefficients of variation were less than 4.1%. Median recovery of nilotinib from plasma was >= 65.1% (+/- 21.4%). The method described is sensitive, selective, reproducible, and rapid, and can be used for the accurate determination of nilotinib in human plasma for pharmacokinetics studies and for therapeutic drug monitoring (TDM) of nilotinib in routine clinical practice.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Micromethod for Quantification of Carbamazepine, Phenobartital and Phenytoin in Human Plasma by HPLC-UV Detection for Therapeutic Drug Monitoring Application
    Sanches, Cristina
    Lopez, Karin V.
    Omosako, Celia E.
    Bertoline, Maria A.
    Pereira, Maria D.
    Santos, Silvia R. C. J.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2008, 27 (04): : 485 - 491
  • [2] Validation of Pyrazinamide in Human Plasma Using Hplc-Uv for Therapeutic Drug Monitoring
    Mulyani, E.
    Darmawan, E.
    Perwitasari, D. A.
    Mulyani, U. A.
    Atthobari, J.
    2016 CONFERENCE ON FUNDAMENTAL AND APPLIED SCIENCE FOR ADVANCED TECHNOLOGY (CONFAST 2016), 2016, 1746
  • [3] Validation and Application of an HPLC-UV Method for Routine Therapeutic Drug Monitoring of Cefiderocol
    Zimmer, Julia
    Roehr, Anka C.
    Kluge, Stefan
    Faller, Jonas
    Frey, Otto R.
    Wichmann, Dominic
    Koenig, Christina
    ANTIBIOTICS-BASEL, 2021, 10 (03): : 1 - 10
  • [4] Validation and Application of an HPLC-UV Method for Routine Therapeutic Drug Monitoring of Dalbavancin
    Chiriac, Ute
    Rau, Heike
    Frey, Otto R.
    Roehr, Anka C.
    Klein, Sabrina
    Meyer, Anna L.
    Morath, Benedict
    ANTIBIOTICS-BASEL, 2022, 11 (05):
  • [5] Quantification and validation of HPLC-UV and LC-MS assays for therapeutic drug monitoring of ertapenem in human plasma
    Pickering, Matthew
    Brown, Stacy
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (05) : 568 - 574
  • [6] Development and Validation of an HPLC-UV Method for Sorafenib Quantification in Human Plasma and Application to Patients With Cancer in Routine Clinical Practice
    Escudero-Ortiz, Vanesa
    Jose Perez-Ruixo, Juan
    Valenzuela, Belen
    THERAPEUTIC DRUG MONITORING, 2014, 36 (03) : 317 - 325
  • [7] Development and Validation of an HPLC-UV Method for Pazopanib Quantification in Human Plasma and Application to Patients With Cancer in Routine Clinical Practice
    Escudero-Ortiz, Vanesa
    Perez-Ruixo, Juan J.
    Valenzuela, Belen
    THERAPEUTIC DRUG MONITORING, 2015, 37 (02) : 172 - 179
  • [8] A Simple HPLC-UV Method for the Quantification of Theophylline in Rabbit Plasma and its Pharmacokinetic Application
    Al-Jenoobi, Fahad I.
    Ahad, Abdul
    Mahrous, Gamal M.
    Raish, Mohammad
    Alam, Mohd Aftab
    Al-Mohizea, Abdullah M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (10) : 1765 - 1770
  • [9] Simple HPLC-UV Method for Therapeutic Drug Monitoring of 12 Antiepileptic Drugs and Their Main Metabolites in Human Plasma
    Milosheska, Daniela
    Roskar, Robert
    D'Orazio, Giovanni
    Atapattu, Sanka N.
    MOLECULES, 2023, 28 (23):
  • [10] HPLC-UV DETERMINATION OF MORPHINE IN HUMAN PLASMA AND ITS APPLICATION TO THE CLINICAL STUDY
    Szkutnik-Fiedler, Danuta
    Grzeskowiak, Edmund
    Gaca, Michal
    Borowicz, Magdalena
    ACTA POLONIAE PHARMACEUTICA, 2011, 68 (04): : 473 - 479