LC-MS/MS methods for the determination of 30 quaternary ammonium compounds including benzalkonium and paraquat in human serum and urine

被引:18
|
作者
Li, Zhong-Min [1 ,2 ]
Lakuleswaran, Mathusa [1 ,2 ]
Kannan, Kurunthachalam [1 ,2 ,3 ]
机构
[1] New York Univ Grossman Sch Med, Dept Pediat, New York, NY 10016 USA
[2] New York Univ Grossman Sch Med, Dept Environm Med, New York, NY 10016 USA
[3] MSB 6-698,550 First Ave, New York, NY 10016 USA
关键词
Benzalkonium; Quaternary ammonium compound; Paraquat; Serum; Urine; Disinfectant; Exposure; Carboxylic benzalkonium; TANDEM MASS-SPECTROMETRY; HERBICIDES PARAQUAT; HIGH-RESOLUTION; COMPOUNDS QACS; DIQUAT; PLASMA; QUANTIFICATION; IDENTIFICATION; VEGETABLES; TOXICITY;
D O I
10.1016/j.jchromb.2022.123562
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Benzalkyldimethylammonium (or benzalkonium; BACs), alkyltrimethylammonium (ATMACs), and dia-lkyldimethylammonium compounds (DDACs) have been widely used for over six decades as disinfectants, especially during the COVID-19 pandemic. Here we describe methods for the determination of 7 BACs, 6 ATMACs, 6 DDACs, 8 BAC metabolites, and the structurally similar quaternary ammonium compound (QAC) herbicides diquat, paraquat, and difenzoquat in human serum and urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The methods were optimized using isotopically labelled internal standards and solid-phase extraction with weak cation-exchange cartridges. We separated diquat and paraquat chro-matographically using a mixed-mode LC column, and BACs, ATMACs, DDACs, difenzoquat, and BAC metabolites using reversed-phase (C8 and C18) LC columns. Method limits of detection (MLODs) and quantification (MLOQs) were 0.002-0.42 and 0.006-1.40 ng/mL, respectively. Recoveries of all analytes fortified at 1, 5, and 20 ng/mL concentrations in serum and urine matrices were 61-129%, with standard deviations of 0-20%. Repeated analysis of similarly fortified serum and urine samples yielded intra-day and inter-day variations of 0.22-17.4% and 0.35-17.3%, respectively. Matrix effects for analytes spiked into serum and urine matrices ranged from -27% to 15.4%. Analysis of real urine and serum samples revealed the presence of several QACs in human serum. Although no parent BACs were found in urine, we detected, for the first time, several to-hydroxy and to-carboxylic acid metabolites of BACs at average concentrations in the range of 0.05-0.35 ng/mL. The developed method is suitable for application in large-scale biomonitoring of human exposure to QACs and their metabolites in human serum and urine.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Simultaneous determination of phosphatidylcholine-derived quaternary ammonium compounds by a LC-MS/MS method in human blood plasma, serum and urine samples
    Steuer, Christian
    Schuetz, Philipp
    Bernasconi, Luca
    Huber, Andreas R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1008 : 206 - 211
  • [2] Determination of palonosetron in human urine by LC-MS/MS
    Wang, Yuanyuan
    Wang, Yongqing
    Zhang, Peipei
    Lu, Zhihong
    Gu, Ying
    Ou, Ning
    BIOANALYSIS, 2011, 3 (12) : 1337 - 1342
  • [3] Determination of finasteride in human serum by LC-MS/MS
    Nam, Hye-Seon
    Nam, Kyong-Hee
    Jung, Su Hee
    Lee, Jang Woo
    Kang, Jin Yeong
    Hong, Soon Keun
    Kim, Tae Sung
    Kang, Tae Seok
    Yoon, Hae-Jung
    Lee, Kwang Ho
    Rhee, Gyu-Seek
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2011, 24 (05): : 345 - 351
  • [4] Determination of isotretinoin in human serum by LC-MS/MS
    Nam, H. S.
    Yoon, H. J.
    Jung, K. K.
    Kang, I. H.
    Kim, T. S.
    Hong, S. K.
    Kang, T. S.
    TOXICOLOGY LETTERS, 2010, 196 : S39 - S39
  • [5] Determination of the quaternary ammonium compound trospium in human plasma by LC-MS/MS: Application to a pharmacokinetic study
    Hotha, Kishore Kumar
    Bharathi, D. Vijaya
    Kumar, Sanagapati Sirish
    Reddy, Y. Narasimha
    Chatki, Pankaj K.
    Ravindranath, L. K.
    Jayaveera, K. N.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (13-14): : 981 - 986
  • [6] Oasis® WCX:: A novel mixed-mode SPE sorbent for LC-MS determination of paraquat and other quaternary ammonium compounds
    Young, MS
    Jenkins, KM
    LC GC NORTH AMERICA, 2004, : 44 - 45
  • [7] Oasis® WCX:: A novel mixed-mode SPE sorbent for LC-MS determination of paraquat and other quaternary ammonium compounds
    Young, MS
    Jenkins, KM
    LC GC EUROPE, 2004, 17 (11A) : 51 - 52
  • [8] Development and validation of a sensitive LC-MS/MS method for the determination of adefovir in human serum and urine
    Sun, Deqing
    Wang, Haisheng
    Wang, Benjie
    Guo, Ruichen
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (03) : 372 - 378
  • [9] Comparison and improvement of the existing methods for the determination of aflatoxins in human serum by LC-MS/MS
    Santini, Antonello
    Ferracane, Rosana
    Meca, Giuseppe
    Ritieni, Alberto
    ANALYTICAL METHODS, 2010, 2 (07) : 884 - 889
  • [10] A simple LC-MS/MS method for determination of sitafloxacin in human urine
    Wang, Yuanyuan
    Liu, Yang
    Zhang, Hongwen
    Wang, Yongqing
    Liu, Yun
    Wang, Libin
    Ou, Ning
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 967 : 219 - 224