Treatment of Coking Wastewater Using Hydrodynamic Cavitation Coupled with Fenton Oxidation Process

被引:1
|
作者
Deng, Dongmei [1 ]
Huang, Ting [1 ]
Li, Qing [1 ]
Huang, Yongchun [1 ]
Sun, Yufei [1 ]
Liang, Jieliang [2 ]
Li, Jintian [2 ]
机构
[1] Guangxi Univ Sci & Technol, Coll Biol & Chem Engn, Guangxi Key Lab Green Proc Sugar Resources, Liuzhou 545006, Peoples R China
[2] South China Normal Univ, Sch Life Sci, Guangdong Prov Key Lab Biotechnol Plant Dev, Inst Ecol Sci,Guangzhou Key Lab Subtrop Biodivers, Guangzhou 510631, Peoples R China
来源
MOLECULES | 2024年 / 29卷 / 05期
基金
美国国家科学基金会;
关键词
coking wastewater; imping stream-hydrodynamic cavitation; Fenton; BIOLOGICAL PROCESSES; DEGRADATION; COMBINATION; INTENSIFICATION; DECOLORIZATION; OPTIMIZATION; COAGULATION; DICHLORVOS; REMOVAL; H2O2;
D O I
10.3390/molecules29051057
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Effective and economical processes for the advanced treatment of coking wastewater were urgently needed to reduce the persistent organic pollutants of external drainage. In the present work, we investigated the degradation of organic pollutants in coking wastewater through IHC/FO (imping stream hydrodynamic cavitation (IHC) coupled with the Fenton oxidation (FO) process) and IHC alone for their feasibility in the advanced treatment of coking wastewater. To select the optimum parameters, attention was paid to the effects of main operation conditions including inlet fluid pressure, medium temperature, initial pH, reaction time, and initial Fe(II) and initial H2O2 concentrations. The results showed that the effects of conditions that need energy to be maintained (such as initial pH and inlet pressure) on the organic pollutant removal efficiency through IHC/FO were less pronounced than those through IHC alone. Moreover, the application of IHC/FO could remove more organic pollutants from coking wastewater than IHC even at an energy-efficient condition. For example, the highest COD removal efficiency of 12.5% was achieved in the IHC treatment at 0.4 MPa, pH 3, and 60 min for the reaction time. In the case of IHC/FO, the maximum COD removal of 33.2% was obtained at pH 7, 0.1 MPa, 12 mmol/L H2O2, and 3 mmol/L Fe2+ after reacting for 15 min. The ultraviolet and visible spectrophotometry (UV-Vis) absorption spectra and gas chromatography and mass spectrometry (GC-MS) analysis further revealed that the kinds and amounts of pollutants (especially those that had benzenes) remaining in water treated through IHC/FO were much fewer and smaller than in water treated through IHC alone. The better performances of IHC/FO than IHC alone were likely related to the more hydroxyl radicals produced through IHC/FO. Taken together, our findings indicate that IHC/FO has great application potential in the advanced treatment of coking wastewater.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Coking wastewater treatment by coagulation coupled with Fenton and hydrodynamic cavitation/Fenton
    Feng, Xingqiao
    Jin, Riya
    Qiao, Yina
    He, Zengdi
    Wang, Kun
    Wang, Chaoqi
    Lu, Yanrong
    Zhang, Yufan
    [J]. DESALINATION AND WATER TREATMENT, 2021, 232 : 105 - 113
  • [2] Treatment of industrial wastewater effluents using hydrodynamic cavitation and the advanced Fenton process
    Chakinala, Anand G.
    Gogate, Parag R.
    Burgess, Arthur E.
    Bremner, David H.
    [J]. ULTRASONICS SONOCHEMISTRY, 2008, 15 (01) : 49 - 54
  • [3] Treatment of coking wastewater by an advanced Fenton oxidation process using iron powder and hydrogen peroxide
    Chu, Libing
    Wang, Jianlong
    Dong, Jing
    Liu, Haiyang
    Sun, Xulin
    [J]. CHEMOSPHERE, 2012, 86 (04) : 409 - 414
  • [4] Optimization of multiple parameters for treatment of coking wastewater using Fenton oxidation
    Verma, Vibha
    Chaudhari, Parmesh Kumar
    [J]. ARABIAN JOURNAL OF CHEMISTRY, 2020, 13 (04) : 5084 - 5095
  • [5] Industrial wastewater treatment using hydrodynamic cavitation and heterogeneous advanced Fenton processing
    Chakinala, Anand G.
    Gogate, Parag R.
    Burgess, Arthur E.
    Bremner, David H.
    [J]. CHEMICAL ENGINEERING JOURNAL, 2009, 152 (2-3) : 498 - 502
  • [6] The Treatment of Nanofiltration Concentrate of Coking Wastewater by Fenton Process
    Wang, Jiao
    [J]. 2019 3RD INTERNATIONAL CONFERENCE ON ENVIRONMENTAL AND ENERGY ENGINEERING (IC3E 2019), 2019, 281
  • [7] Treatment of persistent organic pollutants in wastewater using hydrodynamic cavitation in synergy with advanced oxidation process
    Badmus, Kassim Olasunkanmi
    Tijani, Jimoh Oladejo
    Massima, Emile
    Petrik, Leslie
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (08) : 7299 - 7314
  • [8] Treatment of persistent organic pollutants in wastewater using hydrodynamic cavitation in synergy with advanced oxidation process
    Kassim Olasunkanmi Badmus
    Jimoh Oladejo Tijani
    Emile Massima
    Leslie Petrik
    [J]. Environmental Science and Pollution Research, 2018, 25 : 7299 - 7314
  • [9] Process optimization and degradation mechanism of organic matter in Fenton oxidation treatment of coking wastewater
    Ran, Yu-Fang
    Xu, Chun
    Li, Xin-Peng
    Gong, Yao
    Feng, Wei-Bo
    Hu, Jia-Shuo
    Zhao, Cheng-Wang
    [J]. Zhongguo Huanjing Kexue/China Environmental Science, 2023, 43 (12): : 6329 - 6340
  • [10] Synergistic advance Fenton oxidation and hydrodynamic cavitation treatment of persistent organic dyes in textile wastewater
    Badmus, Kassim O.
    Irakoze, Ninette
    Adeniyi, Olushola Rotimi
    Petrik, Leslie
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2020, 8 (02):