The impact of tube bundle layout on the thermal and fluidic behaviour of liquid lead-bismuth eutectic in a helical-coiled once-through steam generator

被引:0
|
作者
Nuhash, Mashrur Muntasir [1 ]
Karim, Md Rezwanul [1 ]
Bhuiyan, Arafat A. [1 ]
机构
[1] Islamic Univ Technol IUT, Dept Mech & Prod Engn MPE, Gazipur 1704, Bangladesh
关键词
Liquid metal; Lead-bismuth eutectic; Heat transfer; Computational fluid dynamics; Helically-coiled once through steam generator; PRANDTL-NUMBER MODELS; TURBULENT-PRANDTL; HEAT-TRANSFER; APPLICABILITY; FLOWS;
D O I
10.1016/j.heliyon.2024.e24149
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study introduces a numerical model to assess the thermal and frictional properties of LBE crossflow over tube bundles on the shell side of a Helical-coiled Once-Through Steam Generator (H-OTSG) considering different arrangements, including inline, obliquely staggered, triangular, and rotated square configurations. The k-omega SST turbulence model combined with Kays turbulent Prandtl number model is utilized to develop the numerical model. The simulation results have been validated against experimental data and empirical correlations. The layouts of the tube bundles significantly influence the generation of transverse flow, vortical structures and rate of heat transfer in the flow domain. The maximum Nusselt number of 8.2 is observed for the triangular layout as significant crossflow is induced, which is a 10% increase compared to the inline arrangement where the Nusselt number is 7.45. Triangle layouts also exhibit a higher friction factor of 0.45, marking a 20% increase compared to the 0.45 friction factor observed in the inline arrangement. Increasing the oblique angle usually reduces the heat transfer rate and friction factor. Yet, at a 45-degree layout, higher turbulence intensity results in a Nu of 7.05, surpassing 6.93 observed at 30 degrees but falling short of 7.15 at 15 degrees. Nu decreases for rotated square arrangements, but a friction factor greater than the inline arrangement is observed at higher diagonal pitches. The Thermal Enhancement Factor (THEF) is employed to assess the thermal effectiveness of the different tube bundle layouts, and the maximum THEF of 1.1 is observed for the layout with an oblique angle of 45 degrees. Favorable THEF values of 1.06 and 1.05 are recorded for the triangular layout and 30-degree oblique angle, respectively. This numerical study will assist the design and development of LBE H-OTSG.
引用
收藏
页数:13
相关论文
共 13 条
  • [1] Experimental and numerical study of the thermal hydraulics characteristics of a helical-coiled once-through steam generator
    Xu, Ziyi
    Chao, Mengke
    Zhang, Wei
    Zhang, Feixi
    Xiao, Yao
    Liu, Maolong
    Gu, Hanyang
    APPLIED THERMAL ENGINEERING, 2022, 217
  • [2] Model for thermal-hydraulic analysis of once-through helical-coiled steam generator in LMFBRs
    Tsinghua Univ, Beijing, China
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 1997, 37 (02): : 35 - 38
  • [3] Simulation of a Once-Through, Helical-Coiled Steam Generator of High Temperature Gas-Cooled Reactor
    Ye Jinliang
    Zhou Yangping
    Chen Xiaoming
    Ma Yuanle
    Li Fu
    Dong Yujie
    ICONE 17: PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 3, 2009, : 645 - 650
  • [4] Experimental and Numerical Study on Thermal-hydraulics of Helical-coiled Once-through Steam Generator of Small Modular Pressurized Water Reactor
    Liu M.
    Liu L.
    Chao M.
    Zhang W.
    Xiao Y.
    Gu H.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2022, 56 (11): : 2327 - 2333
  • [5] Numerical analysis of liquid metal helical coil once-through tube steam generator
    Yang, Yupeng
    Wang, Chenglong
    Zhang, Dalin
    Lan, Zhike
    Zhu, Dahuan
    Qiu, Suizheng
    Su, G. H.
    Tian, Wenxi
    ANNALS OF NUCLEAR ENERGY, 2022, 167
  • [6] Numerical Study of Liquid Metal Helical Coil Once-through Tube Steam Generator
    Yang Y.
    Wang C.
    Zhang D.
    Su G.
    Tian W.
    Qiu S.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2021, 55 (07): : 1288 - 1295
  • [7] Parametric sensitivity analysis of liquid metal helical coil once-through tube steam generator
    Yang, Yupeng
    Li, Yong
    Wang, Chenglong
    Wang, Tao
    Lan, Zhike
    Zhang, Dalin
    Qiu, Suizheng
    Su, G. H.
    Tian, Wenxi
    NUCLEAR ENGINEERING AND DESIGN, 2021, 383
  • [8] Steady and transient analysis on thermal hydraulic characteristic of helical coiled once-through steam generator of liquid metal fast reactor
    Liu, Jialun
    Li, Huixiong
    Liu, Shuguang
    Tian, Yihang
    Tang, Linghong
    ANNALS OF NUCLEAR ENERGY, 2025, 210
  • [9] Control system design for the once-through steam generator of lead-bismuth cooled reactor based on classical control theory
    Wan, Jiashuang
    Xie, Jingyao
    Wang, Pengfei
    Su, G. H.
    Wu, Shifa
    ANNALS OF NUCLEAR ENERGY, 2022, 175
  • [10] Safety analysis code development and validation for lead-cooled fast reactor with helical coiled once-through steam generator
    Zhang, Jiaxin
    Wang, Chenglong
    Tian, Wenxi
    Su, G. H.
    Qiu, Suizheng
    Xian, Lin
    Cheng, Kun
    Chu, Xiao
    Wei, Shiying
    Chen, Guo