CIE L*A*B* VALUES IN VITA CLASSICAL AND VITA 3D MASTER BY TWO DENTAL SPECTROPHOTOMETERS

被引:6
|
作者
Dias, Susana Beatriz Ferreira
Lourenco Silveira, Joao Miguel
Nunes Pereira, Ruben Miguel
Cardoso, Ana Beatriz
Sola Pereira da Mata, Antonio Duarte
da Silva Marques, Duarte Nuno [1 ]
机构
[1] Univ Lisbon, Fac Dent, Oral Biol & Biochem Res Grp, Cidade Univ,R Prof Teresa Ambrosio, P-1600277 Lisbon, Portugal
关键词
TOOTH COLOR; SHADE; RELIABILITY; ACCURACY; DEVICES; CURVES; AREAS;
D O I
10.11607/ijp.7235
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the CIE L*a*b* values of two different dental shade guides using two shade-matching spectrophotometers. Materials and Methods: SpectroShade Micro (SS) and Easyshade (ES) (VITA Zahnfabrik) were tested. One calibrated operator performed 30 measurements of each tab from three batches of the two guides, VITA Classical (VC) and VITA 3D Shade Master (VM). Receiver operaNng characterisNc (ROC) curves and intraclass coefficients (ICC) between the different batches were calculated. Results were given as mean and SD of the L*a*b* values and the respecNve color differences according to the CIEDE 2000 formula (Delta E-00) for each of the shade tabs in the two spectrophotometers and then analyzed with independent student t test (alpha = .05). Results: A total of 1,440 and 2,610 measurements for VC and VM, respecNvely, were performed per spectrophotometer. There were staNsNcally significant differences between the two devices for all L*a*b* values, with the excepNon of: L* for 3R1.5; a* for 2R1.5, 3L1.5, 2L2.5, 3M2, 3L2.5, 4L1.5, and 4L2.5; and b* for D3, 1M2, and 3M2. When assessing the same shade guide, differences in.E00 were detected between devices above the acceptability threshold (AT) (Delta E-00 >= 1.8) for all shade tabs except for VC (C1, C2, D3, A3.5, C3, and A4) and VM (4M1, 3R2.5, 4L2.5, and 4M3). The overall mean of the interdevice Delta E-00 was 2.2 +/- 1.0 for VC and 2.5 +/- 1.0 for VM. Conclusions: The two dental spectrophotometers presented high ICC and ROC values, which validates their indicaNon as auxiliary tools. However, there are discrepancies in the hues D (VC) and R (VM) with interdevice variability when evaluated for the L*a*b* component.
引用
收藏
页码:E38 / E52
页数:15
相关论文
共 50 条
  • [1] Selecting VITA Classical Shades with the VITA 3D-Master Shade Guide
    Zenthoefer, Andreas
    Wiesberg, Stefan
    Hildenbrandt, Achim
    Reinelt, Gerhard
    Rammelsberg, Peter
    Hassel, Alexander J.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (04) : 376 - 382
  • [2] Determination of VITA Classical shades with the 3D-Master shade guide
    Hassel, Alexander J.
    Zenthoefer, Andreas
    Corcodel, Nicoleta
    Hildenbrandt, Achim
    Reinelt, Gerhard
    Wiesberg, Stefan
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (3-4) : 721 - 726
  • [3] The linear shade guide design of Vita 3D-master performs as well as the original design of the Vita 3D-master
    Corcodel, N.
    Rammelsberg, P.
    Jakstat, H.
    Moldovan, O.
    Schwarz, S.
    Hassel, A. J.
    [J]. JOURNAL OF ORAL REHABILITATION, 2010, 37 (11) : 860 - 865
  • [4] Three-dimensional representation of the Vita Toothguide 3D-Master: An in vivo clinical study
    Gomez-Polo, Cristina
    Fraile, Javier Flores
    Lopez, Norberto Quispe
    Munoz, Maria Portillo
    Lobato, Maria
    Montero, Javier
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (03) : 421 - 428
  • [5] Vita 3D全瓷修复体的临床应用观察
    钟爱喜
    彭利辉
    潘小波
    刘光雪
    李荣婷
    [J]. 中国临床新医学, 2014, 7 (12) : 1130 - 1132
  • [6] VITA 3D-Master比色片数码颜色在Lab颜色空间的分布
    包向军
    贾爽
    王德芳
    叶荣荣
    周立英
    许小会
    [J]. 口腔医学, 2019, (12) : 1099 - 1103
  • [7] Vita 3D-Master比色板与中国人牙齿颜色适合性的临床研究
    谢斌
    姜海英
    杨雷
    [J]. 医学信息, 2009, 22 (05) : 677 - 678
  • [9] 应用VITA3D—MASTER比色系统进行前牙PFM冠选色的初步体会
    冯作业
    [J]. 上海口腔医学, 2003, (02) : 159 - 160
  • [10] 3D Master Toothguide according to L*, C*, and h* coordinates
    Gomez-Polo, Cristina
    Gomez-Polo, Miguel
    Martinez Vazquez De Parga, Juan Antonio
    Celemin-Vinuela, Alicia