Novel technique of entry to re-entry stent grafting enables not only to exclude false lumen but also to perfuse renal artery in patients with chronic Type B aortic dissection

被引:0
|
作者
Samura, Takaaki [1 ]
Fujimoto, Eiki [1 ]
Hata, Hiroki [1 ]
机构
[1] Tokushima Univ, Inst Biomed Sci, Dept Cardiovasc Surg, Grad Sch, Kuramoto Cho 3-18-15, Tokushima 7708503, Japan
关键词
D O I
10.1093/ehjcr/ytad408
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页数:2
相关论文
共 18 条
  • [1] Scheduled re-entry coil embolization before entry coverage of thoracic endovascular stent grafting for aneurysmal chronic type B aortic dissection
    Katayama, Keijiro
    Uchida, Naomichi
    Takahashi, Shinya
    Sueda, Taijiro
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 15 (04) : 800 - 801
  • [2] False Lumen Intercostal Artery Embolization to Halt Type R Entry Flow in Chronic Type B Aortic Dissection
    Yi, Jeniann A.
    Magee, Gregory A.
    Potter, Helen A.
    Kuwayama, David P.
    ANNALS OF VASCULAR SURGERY, 2023, 88 : 1 - 8
  • [3] A Novel "Cheese Wire" Technique for Stent Positioning Following Difficult Iliac Artery Subintimal Dissection and Aortic Re-Entry
    Watkinson, A. F.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (04) : 781 - 784
  • [4] A Novel “Cheese Wire” Technique for Stent Positioning Following Difficult Iliac Artery Subintimal Dissection and Aortic Re-Entry
    A. F. Watkinson
    CardioVascular and Interventional Radiology, 2009, 32 : 781 - 784
  • [5] Cervical Branch Re-entry in Patients With Type A Acute Aortic Dissection is Related to a Patent False Lumen in the Aortic Arch and Enlargement After Ascending Aortic Replacement
    Yasuda, Shota
    Imoto, Kiyotaka
    Uchida, Keiji
    Soda, Susumu
    Karube, Norihisa
    Kasama, Keiichiro
    Minami, Tomoyuki
    Miyamoto, Takuma
    Uranaka, Yasuko
    Goda, Motohiko
    Suzuki, Shinichi
    Masuda, Munetaka
    CIRCULATION, 2015, 132
  • [6] Influence of Distal Re-entry Tears on False Lumen Thrombosis After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection Patients: A Computational Fluid Dynamics Simulation
    Da Li
    Tinghui Zheng
    Zhan Liu
    Yan Li
    Ding Yuan
    Yubo Fan
    Cardiovascular Engineering and Technology, 2021, 12 : 426 - 437
  • [7] Influence of Distal Re-entry Tears on False Lumen Thrombosis After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection Patients: A Computational Fluid Dynamics Simulation
    Li, Da
    Zheng, Tinghui
    Liu, Zhan
    Li, Yan
    Yuan, Ding
    Fan, Yubo
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2021, 12 (04) : 426 - 437
  • [8] Distal re-entry closure with neobranching technique after thoracic endovascular aortic repair of Type B aortic dissection
    Yamamoto, Masaki
    Fukutomi, Takashi
    Noguchi, Tatsuya
    Orihashi, Kazumasa
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (04) : 881 - 883
  • [9] Expanding false lumen in the abdominal aorta 5 years after endovascular repair of a type B aortic dissection: Successful exclusion of 3 distal re-entry sites
    Joung, B
    Ko, YG
    Park, SH
    Lee, DY
    Jang, Y
    Lim, SH
    Shim, WH
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (05) : 577 - 581
  • [10] Use of a stent-graft and vascular occlude to treat primary and re-entry tears in a patient with a Stanford type B aortic dissection
    Shi, Huihua
    Lu, Min
    Jiang, Mier
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2013, 28 (04): : 550 - 554